030000406

Honeywell Main, outside compensated temperature controller heating/burner/DHWS
Accessories

Adapter for DRK mixing valves AT-DRK



030000497

Honeywell Main, outside compensated temperature controller heating/burner/DHWS
Accessories

Adapter for ZRK mixing valves AT-ZRK



075041061

Honeywell Compact Line Rotary Actuator


Linkage of M6063L as replacement for M676A,C



0900153

Honeywell Low pressure pattern pressure reducing valve with balanced seat, D06FN
Spare Parts

Spring bonnet complete, 1/2"+ 3/4"



0900154

Honeywell Low pressure pattern pressure reducing valve with balanced seat, D06FN
Spare Parts

Spring bonnet complete, 1"+ 1 1/4"



0900155

Honeywell Low pressure pattern pressure reducing valve with balanced seat, D06FN
Spare Parts

Spring bonnet complete, 1 1/2"+ 2"



0900247

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN50



0900248

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN65



0900249

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN80



0900250

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN100



0900251

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN125



0900252

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN150



0900253

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Seat bush with seal for size DN200



0900255

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN50



0900256

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN65



0900257

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN80



0900258

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN100



0900259

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN125



0900260

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN150



0900261

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Guide bush with seal for size DN200



0900272

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Spring bonnet complete for sizes 1/4"+ 3/8"



0900273

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Spring bonnet complete for sizes 1/2"+ 3/4"



0900274

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Spring bonnet complete for sizes 1"+ 1 1/4"



0900275

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Spring bonnet complete for sizes 1 1/2"+ 2"



0900311

Honeywell Automatic bypass and differential pressure valve with differential pressure indicator, DU146
Spare parts

Valve insert, 3/4"



0900312

Honeywell Automatic bypass and differential pressure valve with differential pressure indicator, DU146
Spare parts

Valve insert, 1 1/4"



0900356

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Valve disc complete 1/2"



0900357

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Valve disc complete 3/4"



0900358

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Valve disc complete 1"



0900359

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Valve disc complete 1 1/4"



0900360

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Valve disc complete 1 1/2"



0900361

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Valve disc complete 2"



0900376

Honeywell Water station, HS10S-FA
Spare parts

Valve disc guide, DN65



0900377

Honeywell Water station, HS10S-FA
Spare parts

Valve disc guide, DN80



0900378

Honeywell Water station, HS10S-FA
Spare parts

Valve disc guide, DN100



0900379

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN125



0900380

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN150



0900381

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN200



0900382

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN250



0900383

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN300



0900577

Honeywell Automatic air vent with integrated shut-off and leak protection, EA122
Spare parts

Lid complete with float



0900625

Honeywell SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162
Spare Parts

Connection set complete for size 1/2"



0900747

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

O-ring set (10 pcs.) for sizes 1/2" + 1 1/4"



0900748

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

O-ring set (10 pcs.) for sizes 1 1/2" + 2"



0900761

Honeywell Automatic air vent with integrated shut-off and leak protection, EA122
Spare parts

Leak protection discs complete (pack of 5)



0901246

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

O-Ring Satz (10 Stck), 1/2" + 3/4"



0901247

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH
Spare Parts

O-ring set (10 pcs.) 1" + 1 1/4"



0901248

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

O-Ring Satz (10 Stck), 1 1/2" + 2"



0901353

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN50



0901354

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN65



0901355

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN80



0901356

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN100



0901357

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN125



0901358

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN150



0901359

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Set of Seals for size DN200



0901443

Honeywell Refilling combination, NK300S
Spare Parts

Union seal washer (10 pcs.) for size 1/2"



0901444

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Union seal washer(10 pieces), 3/4"



0901445

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Union seal washer(10 pieces), 1"



0901446

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Union seal washer(10 pieces), 1 1/4"



0901447

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Union seal washer(10 pieces), 1 1/2"



0901448

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Union seal washer(10 pieces), 2"



0901499

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

O-Ring Satz (10 Stck), 1" + 1 1/4"



0901515

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F
Spare Parts

Spring bonnet complete with setting scale for sizes 1/2" - 1"



0901516

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Spring bonnet complete 1"+ 1 1/4"



0901517

Honeywell Reverse rinsing fine filter with clear filter bowl, F76CS
Accessories

Spring bonnet complete (with setting scale) for sizes 3/4" - 1 1/4"



0901518

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Spring bonnet complete 1 1/2"+ 2"



0901652

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Inlet ckeck valve for connection sizes DN 65 - 100



0901653

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Outlet ckeck valve for connection sizes DN 65 - 100



0901656

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Inlet ckeck valve for connection size DN 150



0901657

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Outlet ckeck valve for connection size DN 150



0901662

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Ball valve for connection sizes DN 65 - 150



0901768

Honeywell SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162
Spare Parts

Tundish for size 1/2"



0901856

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Discharge valve



0903127

Honeywell Rinsable fine filter, MiniPlus-FF06
Spare Parts

O-ring set for mesh carrier (10 pcs.) for size 1/2"



0903128

Honeywell Rinsable fine filter, MiniPlus-FF06
Spare Parts

O-ring set for mesh carrier (10 pcs.) for sizes 3/4" - 1 1/4"



0903223

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for sizes 1/4"+ 3/8"



0903224

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for size 1/2"



0903225

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for size 3/4"



0903226

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for size 1"



0903227

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for size 1 1/4"



0903228

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for size 1 1/2"



0903229

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Valve cone complete for D22 for size 2"



0903403

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410
Accessories

Adapter for valve series V5077B/V5078B



0903445

Honeywell Filling valve, VF06
Spare parts

Spring bonnet complete



0903454

Honeywell Filling valve, VF06
Accessories

Hose connector union complete With hose connector union, screw and gasket ring



0903733

Honeywell Refilling combination, NK300S
Spare Parts

Cartridge insert complete for size 1/2"



0903745

Honeywell Backflow Preventer for standpipes, BA295STN-A
Spare parts

Cartridge insertcomplete



0903750

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 50



0903751

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 65



0903752

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 80



0903753

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 100



0903754

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 150



0903755

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 200



0903756

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 250



0903757

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 300



0903758

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 350



0903759

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 400



0903760

Honeywell Basic valve, BV300
Spare Parts

Seal Set for DN 450



0903761

Honeywell Magnetic solenoid valve, MV300
Spare Parts

Replacement magnetic solenoid valve, 230 V/50 Hz, normally closed



0903762

Honeywell Magnetic solenoid valve, MV300
Spare Parts

Replacement magnetic solenoid valve, 24 V/50 Hz, normally closed



0903763

Honeywell Pump control valve, PS300
Spare Parts

Replacement magnetic solenoid valve, 24 V AC, normally closed



0903764

Honeywell Pump control valve, PS300
Spare Parts

End switch



0903765

Honeywell Protection valve for deep well pumping, TC300
Spare Parts

Replacement magnetic solenoid valve, normally closed



0903766

Honeywell Protection valve for deep well pumping, TC300
Spare Parts

Replacement magnetic solenoid valve, normally open



0903886

Honeywell Retrofit Backflow Preventer for standpipes, BA295STN
Spare parts

Set of blanking plugs-MS for Option AC12



0903889

Honeywell Retrofit Backflow Preventer for standpipes, BA295STN
Spare parts

Set of blanking plugs-MS for Option A



0903890

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS
Spare Parts

Spring bonnet complete for sizes 1 1/4"- 2"



0903919

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT
Spare Parts

Spring bonnet complete for sizes 1/2"- 1"



0903920

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT
Spare Parts

Spring bonnet complete for sizes 1 1/4"- 2"



0904031

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Sealing set for connection sizes DN 65 - 100



0904032

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Sealing set for connection size DN 150



0904033

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Clamp complete connection sizes DN 65 - 100



0904034

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F
Spare parts

Clamp complete connection size DN 150



0904052

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Inlet check valve for connection size DN65



0904053

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Inlet check valve for connection size DN80



0904054

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Inlet check valve for connection size DN100



0904055

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Inlet check valve for connection size DN150



0904056

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Inlet check valve for connection size DN200



0904057

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Outlet check valve for connection size DN65



0904058

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Outlet check valve for connection size DN80



0904059

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Outlet check valve for connection size DN100



0904060

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Outletcheck valve for connection size DN150



0904061

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Outlet check valve for connection size DN200



0904062

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Discharge valve for connection sizes DN65 - DN200



0904063

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Pressure control line for connection size DN65



0904064

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Pressure control line for connection size DN80



0904065

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Pressure control line for connection size DN100



0904066

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Pressure control line for connection size DN150



0904067

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Pressure control line for connection size DN200



0904068

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Sealing set for connection size DN65



0904069

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Sealing set for connection size DN80



0904070

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Sealing set for connection size DN100



0904071

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Sealing set for connection size DN150



0904072

Honeywell Backflow preventer with flanged connections, BA300
Spare parts

Sealing set for connection size DN200



0904088

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1504B



0904089

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1505B



0904090

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1506B



0904091

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1507B



0904092

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1508B



0904093

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1509B



0904094

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 1510B



0904095

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 2507



0904106

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Pressure switch MCS 22



0904107

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Solenoid valve 1/2"



0904116

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Float switch



0904120

Honeywell Diaphragm-actuated pressure reducing valve with cartridge insert, D15S
Spare Parts

Valve insert complete for sizes DN65, DN80, DN100



0904121

Honeywell Diaphragm-actuated pressure reducing valve with cartridge insert, D15S
Spare Parts

Set of seals complete for sizes DN65, DN80, DN100



0904122

Honeywell Diaphragm-actuated pressure reducing valve with stainless steel cartridge insert, D15SI
Spare Parts

Valve insert complete for sizes DN65, DN80, DN100



0904130

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4003-2



0904131

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4003



0904132

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4004-2



0904133

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4004



0904134

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4005-2



0904135

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4005



0904136

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4006-2



0904137

Honeywell Compact Booster Unit - single pump, CBU144
Spare Parts

Movitec 4006



0904138

Honeywell Refilling combination, NK300S
Spare Parts

Check valve for size 1/2"



0904139

Honeywell Diaphragm-actuated pressure reducing valve with cartridge insert, D15S
Spare Parts

Valve insert complete for sizes DN150 and DN200



0904140

Honeywell Diaphragm-actuated pressure reducing valve with cartridge insert, D15S
Spare Parts

Set of seals complete for sizes DN150 and DN200



0904141

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Cartridge insert complete for connection sizes 1/2", 3/4" and 1" B-version



0904142

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Cartridge insert complete for connection sizes 1" A-version, 11/4"



0904143

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Cartridge insert complete for connection sizes 11/2", 2"



0904144

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Check valve cartridge for connection sizes 1/2", 3/4", 1" B-version



0904145

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Check valve cartridge for connection size 1" A-version



0904146

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Check valve cartridge for connection size 11/4"



0904147

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Check valve cartridge for connection size 11/2"



0904148

Honeywell Backflow preventer compact construction with threaded connectors, BA295S
Spare parts

Check valve cartridge for connection size 2"



0904175

Honeywell Diaphragm-actuated pressure reducing valve with cartridge insert, D15S
Spare Parts

Valve insert complete for sizes DN50



0904176

Honeywell Diaphragm-actuated pressure reducing valve with cartridge insert, D15S
Spare Parts

Set of seals complete for sizes DN50



0904177

Honeywell Retrofit Backflow Preventer for tap fittings and armatures, BA295D-WH/WHS/WHD
Spare parts

Pressure reducing valve insert for BA295D-3/4WHD



1004711

Honeywell Thera-20 (Projecthead Series) Radiator thermostat

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.
TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.
Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.
Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.
Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.
For warm water heating systems
on thermostatic radiator valve bodies, or
on compact radiator valve inserts.
Approvals: Models with M30 x 1.5 connection conform with the European standard EN 215
Setpoint limiting: yes
With internal liquid-filled sensing element
Equipped with easy to use range stoppers
Modern ergonomical design
Sensing element: internal
Colour: white
Closing dimension: 11.5mm
Temperature element: liquid-filled
Cover cap: Honeywell

Thera-2 with internal sensing element
Body-head connection: RA-type
Temp. setpoint range: 6...28C
Zero-position: no
EN215 certified: no


1004712

Honeywell Thera-20 (Projecthead Series) Radiator thermostat

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.
TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.
Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.
Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.
Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.
For warm water heating systems
on thermostatic radiator valve bodies, or
on compact radiator valve inserts.
Approvals: Models with M30 x 1.5 connection conform with the European standard EN 215
Setpoint limiting: yes
With internal liquid-filled sensing element
Equipped with easy to use range stoppers
Modern ergonomical design
Sensing element: internal
Colour: white
Closing dimension: 11.5mm
Temperature element: liquid-filled
Cover cap: Honeywell

Thera-2 with internal sensing element
Body-head connection: M30 x 1,5
Temp. setpoint range: 6...28C
Zero-position: no
EN215 certified: yes


1004714

Honeywell Thera-20 (Projecthead Series) Radiator thermostat

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.
TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.
Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.
Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.
Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.
For warm water heating systems
on thermostatic radiator valve bodies, or
on compact radiator valve inserts.
Approvals: Models with M30 x 1.5 connection conform with the European standard EN 215
Setpoint limiting: yes
With internal liquid-filled sensing element
Equipped with easy to use range stoppers
Modern ergonomical design
Sensing element: internal
Colour: white
Closing dimension: 11.5mm
Temperature element: liquid-filled
Cover cap: Honeywell

Thera-2 with internal sensing element
Body-head connection: RA-type
Temp. setpoint range: 1...26C
Zero-position: yes
EN215 certified: no


1004715

Honeywell Thera-20 (Projecthead Series) Radiator thermostat

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.
TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.
Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.
Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.
Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.
For warm water heating systems
on thermostatic radiator valve bodies, or
on compact radiator valve inserts.
Approvals: Models with M30 x 1.5 connection conform with the European standard EN 215
Setpoint limiting: yes
With internal liquid-filled sensing element
Equipped with easy to use range stoppers
Modern ergonomical design
Sensing element: internal
Colour: white
Closing dimension: 11.5mm
Temperature element: liquid-filled
Cover cap: Honeywell

Thera-2 with internal sensing element
Body-head connection: M30 x 1,5
Temp. setpoint range: 1...26C
Zero-position: yes
EN215 certified: yes


101050

Honeywell V6000 Kombi-F, Flanged Double-Regulating Balancing Valve with SafeCon Measuring Connections
Accessories

Insulation shells for valves DN50



101065

Honeywell V6000 Kombi-F, Flanged Double-Regulating Balancing Valve with SafeCon Measuring Connections
Accessories

Insulation shells for valves DN65



101080

Honeywell V6000 Kombi-F, Flanged Double-Regulating Balancing Valve with SafeCon Measuring Connections
Accessories

Insulation shells for valves DN80



101100

Honeywell V6000 Kombi-F, Flanged Double-Regulating Balancing Valve with SafeCon Measuring Connections
Accessories

Insulation shells for valves DN100



101125

Honeywell V6000 Kombi-F, Flanged Double-Regulating Balancing Valve with SafeCon Measuring Connections
Accessories

Insulation shells for valves DN125



101150

Honeywell V6000 Kombi-F, Flanged Double-Regulating Balancing Valve with SafeCon Measuring Connections
Accessories

Insulation shells for valves DN150



1030002020

Honeywell Valve proving system A4021
Accessoires

Mounting bracket for VQ400 and VE5000 series.



113228/U

Honeywell UV flame sensors C7012A/C/E/F/G
Replacement parts

Ultraviolet sensing tube for C7012 sensor



114465/U

Honeywell UV flame sensors C7061A/F
Accessories

Gasket, silicone rubber. For installing viewing window or lens(3pcs required)



117053/U

Honeywell Burner Controls DBC2000-series
Accessories for use with DBC2000 (see dedicated chapter for details)

Cable (ca. 250mm) with jack plug for remote 0..15 micro-ampere flame signal reading. For use with jack plug socket on the front of DBC2000 and R4343 or on plug-in amplifier of R4348.



118367A/U

Honeywell UV flame sensors C7012A/C/E/F/G
Accessories

Swivel mount for adjustable positioning of the UV sensor



124198/U

Honeywell UV flame sensors C7012A/C/E/F/G
Accessories

Mounting flange with 1" NPT internal thread for mounting on 1" sight pipe (to replace standard 3/4" NPT flange), for C7012A/E/G only



124204/U

Honeywell UV flame sensors C7012A/C/E/F/G
Accessories

Quartz focussing lens



129464M/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")
Replacement tube for C7035

Ultraviolet sensing tube (-18o to 121oC) for C7035/C7061 flame scanners



129464N/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")
Replacement tube for C7035

Ultraviolet sensing tube (-40o to 121oC) for C7035/C7061 flame scanners



13121U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Dual pole models (oil and dual fuel); ZT930-series
Features: 1 mm HV
Supply voltage: 220..240 Vac
Output voltage: 2x 7 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


13124U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Dual pole models (oil and dual fuel); ZT930-series
Features: 4 mm HV
Supply voltage: 220..240 Vac
Output voltage: 2x 7 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


13131U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Single pole models (gas); ZT931-series
Features: 1 mm HV
Supply voltage: 220..240 Vac
Output voltage: 1x 14 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


1313405U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Single pole models (gas); ZT931-series
Features: 4 mm HV
Supply voltage: 220..240 Vac
Output voltage: 1x 14 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


13134U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Single pole models (gas); ZT931-series
Features: 4 mm HV
Supply voltage: 220..240 Vac
Output voltage: 1x 14 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


13174

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Dual pole models (oil and dual fuel); ZT930-series
Features: 4 mm HV
Supply voltage: 24 Vdc
Output voltage: 2x 7 kV
Current: 17 mA rms
Power consumption: 60W
Comment: Pack size 50 pcs!
Output frequency: ...20kHz


13224U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Dual pole models (oil and dual fuel); ZT930-series
Features: 4 mm HV
Supply voltage: 110..120 Vac
Output voltage: 2x 7 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


13231U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Single pole models (gas); ZT931-series
Features: 1 mm HV
Supply voltage: 110..120 Vac
Output voltage: 1x 14 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


13234U

Honeywell Electronic Spark Ignition generator, ZT93x-series

The ZT 93x-series high frequency (20 kHz) spark ignition transformer is suitable for use with medium sized oil, gas and dual fuel burners.
the single pole model (ZT931) is designed for use with gas burners (spark to ground)
the dual pole model (ZT930) is designed for use with oil and/or dual fuel burners (spark between 2 electrodes)
Weight: 280g
Protection class: IP40, for models with 1 mm clip connection for high voltage cable.
The ZT93x-series ignition transformer is available in 2 versions:
with 1 mm high voltage cable connection. This is the more robust model for optimal insulation of the high voltage and strong fixation of the cable in the transformer. To be used with the 1 mm clip and 7 mm diameter high voltage silicone cable.
with 4 mm high voltage cable connection. This is the general purpose model, that can be used with several brands of high voltage cables available in the market.
Ambient temperature: -10...60C
Note: The duty cycle is maximal 33% during 3 minutes of operation.

Single pole models (gas); ZT931-series
Features: 4 mm HV
Supply voltage: 110..120 Vac
Output voltage: 1x 14 kV
Current: 40 mA rms
Power consumption: 60W
Output frequency: ...20kHz


133568/U

Honeywell Fluid power actuators for safety shut-off gas valve VE5000-series
Accessories

Auxiliary Switch Bag Assembly (not for models with maximum flow limit switch).



133569/U

Honeywell Fluid power actuators for safety shut-off gas valve VE5000-series
Accessories

Valve-Closed Indication Switch Bag Assembly



14004406-120/U

Honeywell Pneumatic room temperature controller, TP970


Satin chrome cover



14004406-124/U

Honeywell Pneumatic room humidity sensor, HP971


Cover



14004406-300/U

Honeywell Pneumatic room temperature sensor, TP974


Cover without scale



14004458-001/U

Honeywell Pneumatic room temperature sensor, TP974


Spacer ring for wall mounting



14026/U

Honeywell Pressuretrol Controllers


Steam Trap Black Iron Siphon Loop for L404 or L91



18040824-CBU

Honeywell Compact Booster Unit - single pump, CBU140
Spare parts

Seal set



18040893-CBU

Honeywell Compact Booster Unit - single pump, CBU140
Spare parts

Float valve (complete)



18041119-CBU

Honeywell Compact Booster Unit - single pump, CBU140
Spare parts

Pump incl. set of seal elements



18041125-CBU

Honeywell Compact Booster Unit - single pump, CBU140
Spare parts

Pump drive



190971B/U

Honeywell UV flame sensors C7012A/C/E/F/G
Replacement parts

Coil and shutter assembly for C7012E/F models only



190971E/U

Honeywell UV flame sensors C7076
Replacement shutter assembly for C7076

Replacement shutter and coil assembly for C7076, with black painted shutter



191002B/U

Honeywell UV flame sensors C7076
Replacement internal chassis for C7076

Replacement electronic chassis module, excluding sensing tube for C7076A/D models (120Vac)



191002BF

Honeywell UV flame sensors C7076
Replacement internal chassis for C7076

Replacement electronic chassis module, excluding sensing tube for C7076F models (120Vac)



191002D/U

Honeywell UV flame sensors C7076
Replacement internal chassis for C7076

Replacement electronic chassis module, excluding sensing tube for C7076A/D models (230Vac)



191002DF

Honeywell UV flame sensors C7076
Replacement internal chassis for C7076

Replacement electronic chassis module, excluding sensing tube for C7076F models (230Vac)



191053/U

Honeywell UV flame sensors C7076
Replacement tube for C7076

Ultraviolet sensing tube for C7076 sensor



203541/U

Honeywell Burner Controls EC/RM7800-series
Parts

5-wire connector for S7800/10/20



203765/U

Honeywell Burner Controls EC/RM7800-series
Parts

Remote mounting bracket for S7800



2061400

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Spring 1/2"



2061500

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Spring 3/4"



2061600

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Spring 1"



2061700

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Spring 1 1/4"



2062000

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Spring 1 1/2"



2062400

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Spring 2"



2067300

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN150



2070300

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN125



2074900

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Spring for sizes 1/2" - 1 1/4"



2110200

Honeywell Combination water supply unit, HS10S
Spare Parts

Check valve cartridge for size 3/4"



2110400

Honeywell Fully automatic combination water supply unit with automatic reverse rinsing actuator, HS74CA
Spare Parts

Non-return valve cartridge, for R 1 inch



2110500

Honeywell Fully automatic combination water supply unit with automatic reverse rinsing actuator, HS74CA
Spare Parts

Non-return valve cartridge, for R 1 1/4 inch



2159400

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Spring for sizes 1 1/2" - 2"



2164400

Honeywell Combination water supply unit, HS10S
Spare Parts

Check valve cartridge for size 1"



2164500

Honeywell Combination water supply unit, HS10S
Spare Parts

Check valve cartridge for size 1 1/4"



2164600

Honeywell Combination water supply unit, HS10S
Spare Parts

Check valve cartridge for size 1 1/2"



2164700

Honeywell Combination water supply unit, HS10S
Spare Parts

Check valve cartridge for size 2"



2166200

Honeywell Filling valve, VF06
Spare parts

Check valve



2166600

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Seal ring, DN40 - DN50



2192900

Honeywell Softening unit for heating systems, VE300
Accessories

Shutoff valve Connection size 1/2"



2193100

Honeywell Combination water supply unit, HS10S
Spare Parts

Shut-off valve for size 3/4"



2193200

Honeywell Combination water supply unit, HS10S
Spare Parts

Shut-off valve for size 1"



2193300

Honeywell Combination water supply unit, HS10S
Spare Parts

Shut-off valve for size 1 1/4"



2193400

Honeywell Combination water supply unit, HS10S
Spare Parts

Shut-off valve for size 1 1/2"



2193500

Honeywell Combination water supply unit, HS10S
Spare Parts

Shut-off valve for size 2"



2202500

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Diaphragm for sizes 1/4"+ 3/8"



2202700

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Diaphragm for sizes 1/2"+ 3/4"



2203300

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Diaphragm for sizes 1"+ 1 1/4"



2204100

Honeywell Standard pattern pressure reducing valve for compressed air with piston balanced seat, D22
Spare Parts

Diaphragm for sizes 1 1/2"+ 2"



220736B/U

Honeywell Modutrol IV servo motors
Accessories

Replacement dual internal auxiliary switch kit



220738A/U

Honeywell Modutrol IV servo motors
Accessories

Adapter bracket to adjust shaft height when replacing old ModII or ModIII motors.



221455A/U

Honeywell Modutrol IV servo motors
Accessories

Adjustable cranc arm kit



221818A/U

Honeywell Burner Controls EC/RM7800-series
Parts

Display extension cable assembly. Cable length 1.5 m



221818C/U

Honeywell Burner Controls EC/RM7800-series
Parts

Display extension cable assembly. Cable length ca. 3 m. Note: assure no electrical noise is present to avoid connection problems, due to extra long cable.



2221300

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 1/2"



2238700

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN40



2238800

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN50



2238900

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN200



2239000

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN250



2239100

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Lip seal ring, DN300



2248700

Honeywell Water station, HS10S-FA
Spare parts

Hexagonal blanking plug, DN65-100



2421100

Honeywell Refilling combination with softening unit , NK300S-SOFT
Spare Parts

Air bleed valve



2596600

Honeywell SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162
Spare Parts

Flanged offset angled tube for size 1/2"



2597200

Honeywell SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162
Spare Parts

Angle tube 0 for size 1/2"



2657800

Honeywell Float valve for water storage tanks, VR 170
Spare Parts

Sealing Disc for R 1/2" and R 3/4"



2658000

Honeywell Float valve for water storage tanks, VR 170
Spare Parts

Sealing Disc for R 1"



2658100

Honeywell Float valve for water storage tanks, VR 170
Spare Parts

Sealing Disc for R 1/1/4"



2658200

Honeywell Float valve for water storage tanks, VR 170
Spare Parts

Sealing Disc for R 11/2"



2658300

Honeywell Float valve for water storage tanks, VR 170
Spare Parts

Sealing Disc for R 2"



2658400

Honeywell Float valve for water storage tanks, VR 170
Spare Parts

Sealing Disc for R 21/2"



32002935-001/U

Honeywell ControLinks - Electronic Fuel-Air Ratio Control System
Accessories for ML7999 actuators

Weather proofing kit (NEMA 3 - IP54) for ML7999



324721A

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 100S8111-CA22-D1B03


324721B

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 100S8111-CA22-A1B03


324721C

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 100S8111-CA22-G1B03


324721J

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions, ATEX Cat.2GD
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 100S8113-CA22-J1B03


324722A

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 150S8111-CA22-D1B03


324722B

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 150S8111-CA22-A1B03


324722C

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 150S8111-CA22-G1B03


324722J

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions, ATEX Cat.2GD
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 150S8113-CA22-J1B03


324723A

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 200S8111-CA22-D1B03


324723B

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 200S8111-CA22-A1B03


324723C

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 200S8111-CA22-G1B03


324723J

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions, ATEX Cat.2GD
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 17.6bar
Product description: SSOV 200S8113-CA22-J1B03


324724A

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 12.1bar
Product description: SSOV 250C8111-DA22-D1B03


324724B

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 12.1bar
Product description: SSOV 250C8111-DA22-A1B03


324724C

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 12.1bar
Product description: SSOV 250C8111-DA22-G1B03


324724J

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions, ATEX Cat.2GD
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 12.1bar
Product description: SSOV 250C8113-DA22-J1B03


324726A

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 300C8111-DA22-D1B03


324726B

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 300C8111-DA22-A1B03


324726C

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 300C8111-DA22-G1B03


324726J

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions, ATEX Cat.2GD
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 300C8113-DA22-J1B03


324727A

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 400C8111-DA22-D1B03


324727B

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 400C8111-DA22-A1B03


324727C

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 400C8111-DA22-G1B03


324727J

Honeywell Pneumatic shut off gas valve, normally closed type 8000

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Pneumatic actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...100C
Materials: Carbon or stainless steel body
Available on request: Special versions for low temperatures (till -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Other options, available on request:
special firesafe- and NACE versions
partial stroke testing
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL, CSA, KTL and/or INMETRO approved models
Operating Environment:
Actuators are rated for NEMA 4, IP65 or optional NEMA 4X, IP65.
Ambient temperature range of -40C to 60C for the 8111 models; option of -50C to 60C also available.
Ambient temperature range of -40C to 50C for the 8113 models; option of -50C to 50C also available.
All valves for oxygen service or using Ethylene Propylene body seals are limited to a minimum ambient and fluid temperature of -17C.
Maximum closing time: 1s
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions, ATEX Cat.2GD
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 9.3bar
Product description: SSOV 400C8113-DA22-J1B03


325521A

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 8.62bar
Product description: 5000 100SMA11 CA22-CC13B0


325521B

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 8.62bar
Product description: 5000 100SMA11 CA22-AA13B0


325521C

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: Rp 1
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 8.62bar
Product description: 5000 100SMA11 CA22-FE24B0


325522A

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 4.83bar
Product description: 5000 150SMA11 CA22-CC13B0


325522B

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 4.83bar
Product description: 5000 150SMA11 CA22-AA13B0


325522C

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: Rp 1 1/2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 4.83bar
Product description: 5000 150SMA11 CA22-FE24B0


325523A

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 4.83bar
Product description: 5000 200SMA11 CA22-CC13B0


325523B

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 4.83bar
Product description: 5000 200SMA11 CA22-AA13B0


325523C

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: Rp 2
Pipe connection: Internal threads
Threads type: BSP
Max. operating pressure: 4.83bar
Product description: 5000 200SMA11 CA22-FE24B0


325531A

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 3.45bar
Product description: 5000 250CMA11 DA22-CC23B0


325531B

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 3.45bar
Product description: 5000 250CMA11 DA22-AA23B0


325531C

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: DN65
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 3.45bar
Product description: 5000 250CMA11 DA22-FE24B0


325532A

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 2.76bar
Product description: 5000 300CMA11 DA22-CC23B0


325532B

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 2.76bar
Product description: 5000 300CMA11 DA22-AA23B0


325532C

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: DN80
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 2.76bar
Product description: 5000 300CMA11 DA22-FE24B0


325533A

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

230 Vac, 50/60 Hz versions
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 2.76bar
Product description: 5000 400CMA11 DA22-CC23B0


325533B

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

120 Vac, 50/60 Hz versions
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 2.76bar
Product description: 5000 400CMA11 DA22-AA23B0


325533C

Honeywell Electro Mechanical gas valve, normally closed type MA

Automatic shut off valve for use with variety of gaseous media.
For use with industrial burners on ovens, furnaces and other gas consuming appliances.
Gas valve type: Electro mechanically actuated shut off valve
Media: Natural gas, propane, butane, hydrogen
Available on request: Special versions for oxygen, coke oven gas, refinery gas, biogas.
Ambient temperature: -40...60C
Materials: Carbon steel body
Available on request: Special versions with stainless steel or low temperature carbon steel (as low as -50C).
Connections:
ISO 7-1 threaded or DIN PN16 Flanged
Available on request: Special versions with NPT pipe thread, ANSI Flanged or with Socket welded nipple.
Approvals: GAD, EN161, PED, FM, AGA, TR (Russia)
SIL-3 Capable (meets IEC61508)
Available on request: UL and CSA approved models
Maximum closing time: 1s
Electrical connection: screw terminals
Protection class: NEMA 4 (IP65)
Note: Maximum operating pressures to be reduced with 25% when used with hydrogen (H2)

24 Vdc versions
Valve dimension: DN100
Pipe connection: Flanges
Threads type: no
Max. operating pressure: 2.76bar
Product description: 5000 400CMA11 DA22-FE24B0


40007035-005

Honeywell VC Series Motorized Zone Valves - Actuators
Accessories

VC Series 3-wire cable with Molex(TM) plug



4074ERU/U

Honeywell Modutrol IV servo motors
Accessories

Weatherproofing kit. Protects motor from driving rain when mounted in any position



43161276-001

Honeywell Pneumatic actuator, MP953
High Temperature Applications, the following bonnet extentions must be used with MP953 actuators when the flowing medium temperature is 150 to 220 degrees C, to give extra air circulation and less conduction of heat from the valve body to the actuator.

Used with V5049A up to 65mm, V5050A up to 80mm, V5328A 40mm to 80mm, V5329A 40mm to 80mm



43163162-001

Honeywell Pneumatic temperature sensor, LP914
Accessories

Stainless steel well, 380 mm 1/2" NPT



43191679-001

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 220/135 ohm operating range, for 20 mm models



43191679-002

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 220/135 ohm operating range, for 38 mm models



43191679-007

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 10 kohm operating range, for 20 mm models



43191679-008

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 10 kohm operating range, for 38 mm models



43191679-011

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Feedback potentiometer 10 kohm, operating range



43191679-012

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Feedback potentiometer 220 ohm operating range



43191680-002

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Dual end switches SPDT, adjustable (250 V~, 10 A)



43191680-005

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Dual end switches SPDT, adjustable (250 V~, 10 A)



43191680-205

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425
Accessories

Auxiliary switch (250 V~, 10 A)



43196000-001

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
High temperature kits for:

V5011R/S, V5013R/E; V5328A/V5329A DN15..32



43196000-002

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
High temperature kits for:

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80



43196000-038

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
High temperature kits for:

V5015A/V5016A/V5025A/V5049A/V5050A/B/V5328A 38 mm



43297431-001

Honeywell Pneumatic actuator, MP953
High Temperature Applications, the following bonnet extentions must be used with MP953 actuators when the flowing medium temperature is 150 to 220 degrees C, to give extra air circulation and less conduction of heat from the valve body to the actuator.

Used with V5011R,S, V5013R,E, V5328A 15mm to 32mm, V5329A 15mm to 32mm



45.002.208-001B

Honeywell Pressure switch for general gas- and air application C6045D


Mounting bracket with screws (20sets per carton)



45002041-001

Honeywell Thermocouple Q331-family
Features

A: Nut Thermocouple 7/16" Hex 11



45002120-001

Honeywell Thermocouple Q331-family
Features

B: Adapter ring 10 x 8.5 mm



45002379-001

Honeywell Thermocouple Q370-family
Features

C: Connector power unit M10 x 1 Hex 10



45002381-001

Honeywell Thermocouple Q370-family
Features

D: Knurl nut 9.5 x 8 mm



45002383-001

Honeywell Thermocouple Q370-family
Features

E: Bushing 10 x 20 mm



45002493-001

Honeywell Thermocouple Q370-family
Features

F: Connector power unit M10 x 1 Hex 12



45002746-001

Honeywell Thermocouple Q370-family
Features

G: Connector power unit M9 x 1 Hex 9



45002776-003

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl + screws + "O"-ring (Unit pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45002776-004

Honeywell Flanges Gas Control


Straight
Product description: 3/4" BSP. Pl + screws + "O"-ring (Unit pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45002776-005

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl + screws + "O"-ring (Unit pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45002776-006

Honeywell Flanges Gas Control


Elbow
Product description: 3/4" BSP. Pl + screws + "O"-ring (Unit pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45002776-018

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 6 mm 7/16


45002776-019

Honeywell Fittings and Adaptors


Ferrule (olive only)
Product description: Ferrule 4 mm; 7/16"-24NS-2A (Unit pack). FOR: Q334


45002776-037

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 6 mm M11x1, L=17.7 mm (Unit pack). FOR: Q349, Q359, Q371, Q385, Q389, Q395, V44../88, V46../86.., V5435, VK41../VK81..R, VR46../86, V(R)49../89


45002776-041

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl + screws + "O"-ring (Unit pack). FOR: VK41../81.., V(R)47../87


45002776-042

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl + screws + "O"-ring (Unit pack). FOR: VK41../81.., V(R)47../87


45006034-001

Honeywell Thermocouple Q370-family
Features

H: Compression nut M10 x 1 Hex 10



45006046-001

Honeywell Thermocouple Q331-family
Features

C: Spacer 8 x 23 mm



45006049-002

Honeywell Thermocouple Q331-family
Features

D: Spacer 6.5 x 12 mm



45900400-101

Honeywell Flanges Gas Control


Straight
Product description: 3/8" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-102

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-103

Honeywell Flanges Gas Control


Elbow
Product description: 3/8" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-104

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-106

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-108

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-122

Honeywell Flanges Gas Control


Straight
Product description: 1/2" NPT + screws + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-125

Honeywell Flanges Gas Control


Elbow
Product description: 3/4" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-129

Honeywell Flanges Gas Control


Elbow
Product description: 3/8" BSP. Pl + "O"-ring (Bulk pack). FOR: VK41../81..


45900400-130

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-131

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-132

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" NPT + screws + "O"-ring (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-133

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-134

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-135

Honeywell Flanges Gas Control


Straight
Product description: 1/2" BSP. Pl (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-136

Honeywell Flanges Gas Control


Straight
Product description: 1/2" NPT + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-137

Honeywell Flanges Gas Control


Straight
Product description: 3/4" BSP. Pl (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-138

Honeywell Flanges Gas Control


Straight
Product description: 3/4" NPT + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-139

Honeywell Flanges Gas Control


Straight
Product description: 3/4" BSP. Pl + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-141

Honeywell Flanges Gas Control


Elbow
Product description: M22 x 1 + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-142

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-143

Honeywell Flanges Gas Control


Elbow
Product description: 1/2" BSP. Pl (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-144

Honeywell Flanges Gas Control


Elbow
Product description: 3/4" NPT + screws + "O"-ring (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-145

Honeywell Flanges Gas Control


Elbow
Product description: 3/4" BSP. Pl (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V(R)49../89..


45900400-146

Honeywell Flanges Gas Control


Straight
Product description: 1/2" NPT + screws + "O"-ring. Left handed thread. (Bulk pack). FOR: VK41../81.., V(R)47../87


45900400-150

Honeywell Flanges Gas Control


Straight
Product description: 3/4" ISO- 228 + screws + "O"-ring + valve pressure tap (Bulk pack). FOR: VK41../81..


45900401-007

Honeywell Cover and Plug


Cover
Product description: Overall cover + conduitplate + screw (Bulk pack). FOR: V47..87..


45900401-008

Honeywell Cover and Plug


Cover
Product description: Overall cover + conduitplate + screw (Bulk pack). FOR: VR47../87..


45900401-032

Honeywell Cover and Plug


Cover
Product description: Overall cover (Bulk pack). FOR: V47..87..


45900401-044

Honeywell Cover and Plug


Cover
Product description: Cover red (without reset sticker) + screw (Bulk pack). FOR: S4565/4585


45900401-046

Honeywell Cover and Plug


Cover
Product description: Cover red (without reset sticker)+gasket+screw (for IP44) (Bulk pack). FOR: S4565/4585


45900402-001

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 1/4" M11x1, L=17.7 mm (Bulk pack). FOR: V44../88, V46../86.., VR46../86, V(R)49../89


45900402-002

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 6 mm M11x1, L=17.7 mm (Bulk pack). FOR: Q349, Q359, Q371, Q385, Q389, Q395, V44../88, V46../86.., V5435, V5475, VK41../VK81..R, VR46../86


45900402-003

Honeywell Fittings and Adaptors


Ferrule (olive only)
Product description: Ferrule 4 mm M11x1 (gland and ferrule) (Bulk pack). FOR: Q349, Q359, Q371, Q385, Q389, Q395, V44../88, V46../86.., VR46../86, V(R)49../89


45900402-004

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 4 mm M11x1, L=19.5 mm (Bulk pack). FOR: V(R)49../89


45900402-007

Honeywell Fittings and Adaptors


Ferrule (olive only)
Product description: Ferrule 4 mm M11x1 (stainless steel) (Bulk pack). FOR: Q349, Q359, Q371, Q385, Q389, Q395, V44../88, V46../86.., VR46../86, V(R)49../89


45900402-008

Honeywell Fittings and Adaptors


Gland
Product description: Gland 4 mm M11x1 (stainless steel) (Bulk pack). FOR: Q349, Q359, Q371, Q385, Q389, Q395, V44../88, V46../86.., VR46../86, V(R)49../89


45900402-009

Honeywell Fittings and Adaptors


Taper bush / pipe bushing
Product description: Taper-bush 5 mm for pressure feedback (Bulk pack). FOR: V44../88, V46../86.., VR46../86, V(R)49../89


45900402-010

Honeywell Fittings and Adaptors


Pressure feeback for tube
Product description: Pressure feedback fitting for tube D4 x 1 (Bulk pack). FOR: V44../88, V46../86.., VR46../86, V(R)49../89


45900402-011

Honeywell Fittings and Adaptors


Pressure feeback for tube
Product description: Pressure feedback fitting for tube D6 x 1 (Bulk pack). FOR: V44../88, V46../86.., VR46../86, V(R)49../89


45900402-014

Honeywell Fittings and Adaptors


Gland
Product description: Gland 4 mm M10x1 (brass) (Bulk pack). FOR: V5475


45900402-015

Honeywell Fittings and Adaptors


Ferrule (olive only)
Product description: Ferrule 4 mm (brass) (Bulk pack). FOR: V5475


45900402-019

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 4 mm M8x1, L=16.5 mm (Bulk pack). FOR: V5435, VK41../VK81..


45900402-031

Honeywell Fittings and Adaptors


Pressure feeback for tube
Product description: Pressure feedback fitting for tube D4 (Bulk pack). FOR: V46../86.., VK41../VK81.., VR46../86


45900402-033

Honeywell Fittings and Adaptors


Taper bush / pipe bushing
Product description: Taper-bush 4 mm for pressure feedback (Bulk pack). FOR: V44../88, V46../86.., VR46../86, V(R)49../89


45900402-034

Honeywell Fittings and Adaptors


Pressure feeback for tube
Product description: Pressure feedback fitting for tube D6 x 1 (Bulk pack). FOR: V46../86.., VK41../VK81.., VR46../86


45900402-040

Honeywell Fittings and Adaptors


Taper bush / pipe bushing
Product description: Pipe bushing 3/4" BSP.T x 1/2" BSP.PL (Unit pack). FOR: V44../88


45900402-041

Honeywell Fittings and Adaptors


Taper bush / pipe bushing
Product description: Pipe plug M11 x 1 (Unit pack). FOR: V44../88


45900402-042

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 6 mm M11x1, L=21.7 mm (Bulk pack). FOR: VR46../86, V(R)47../87


45900402-044

Honeywell Fittings and Adaptors


Compression fitting, with olive
Product description: Compression fitting 6 mm M10x1, L=21.7 mm (Bulk pack). FOR: V(R)49../89


45900402-045

Honeywell Fittings and Adaptors


Pressure feeback for tube
Product description: Pressure feedback connection CVI-m (Bulk pack). FOR: VK41../VK81..


45900405-002

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 21,9 (Bulk pack). FOR: VR47../87..


45900405-003

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 23.47 x 2.62 (used for Venturi orifice 45900450 serie) (Bulk pack). FOR: 45900450, VR46../86..


45900405-004

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 33 x 2 (used for mounting 45900450 serie) (Bulk pack). FOR: 45900450, VR46../86..


45900405-005

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 24 x 2 (Bulk pack). FOR: VK45../85..


45900405-008

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 17.1 x 0.3 (used for injector assy for pipe connection mini vent.) (Bulk pack). FOR: VK41../81..


45900405-009

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 44.04 x 0.4 (used for mounting mini venturi to fan) (Bulk pack). FOR: VK41../81..


45900405-010

Honeywell Gas valve accessories


O-ring
Product description: O-ring dia 17.7 x 4.2 (used for mini venturi pipe connection) (Bulk pack). FOR: VK41../81..


45900406-001U

Honeywell Gas valve accessories


Coil
Product description: Coil 24V for direct operator (Unit pack). FOR: VR47../87..


45900406-002U

Honeywell Gas valve accessories


Coil
Product description: Coil 220V for direct operator (Unit pack). FOR: VR47../87..


45900406-003U

Honeywell Gas valve accessories


Coil
Product description: Coil 240V for direct operator (Unit pack). FOR: VR47../87..


45900406-004U

Honeywell Gas valve accessories


Coil
Product description: Coil 220/240V for direct operator; med. capacity; bottom conn. (Unit pack). FOR: VR46../86..


45900406-008U

Honeywell Gas valve accessories


Coil
Product description: Coil 220/240V for direct operator; med. capacity; top conn. (Unit pack). FOR: VR46../86..


45900406-009U

Honeywell Gas valve accessories


Coil
Product description: Coil 220/240V for direct operator, top conn. (Unit pack). FOR: VR46../86..


45900406-010U

Honeywell Gas valve accessories


Coil
Product description: Coil 220/240V for direct operator, low capacity, bottom conn. (Unit pack). FOR: VR46../86..


45900411-001

Honeywell Electronic accessories


Ignition cable
Product description: Ignition cable 500 mm (Bulk pack). FOR: S4560, S4561, S4565, S4570, S4582


45900411-003

Honeywell Electronic accessories


Ignition cable
Product description: Ignition cable 1000 mm (Bulk pack). FOR: S4560, S4561, S4570, S4582


45900411-011

Honeywell Electronic accessories


Ignition cable
Product description: Ignition cable 500 mm (Bulk pack). FOR: S4560, S4561, S4565, S4570, S4582


45900411-012

Honeywell Electronic accessories


Ignition cable
Product description: Ignition cable 1000 mm (Bulk pack). FOR: S4560, S4561, S4570, S4582


45900419-002

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 3 Poles (Bulk pack). FOR: S4560


45900419-003

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 5 Poles (Bulk pack). FOR: S4560


45900419-004

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 6 Poles (Bulk pack). FOR: S4560


45900419-011

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 6 Poles (Bulk pack). FOR: S4570


45900419-020

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 2 Poles jumper (Bulk pack). FOR: S4570


45900419-021

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 2/3 Poles; potmeter (Bulk pack). FOR: S4582


45900419-022

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 12 Poles (Bulk pack). FOR: S4565


45900419-023

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 12 Poles (Bulk pack). FOR: S4565


45900419-024

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 12 Poles (Bulk pack). FOR: S4565


45900419-025

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 10 Poles (Bulk pack). FOR: S4565


45900419-026

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 3 Poles; potmeter (Bulk pack). FOR: S4582


45900419-033

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 12 Poles (Bulk pack). FOR: S4565


45900419-035

Honeywell Electronic accessories


Wiring accessories
Product description: Rectifier assembly (Bulk pack). FOR: W7075C


45900419-037

Honeywell Electronic accessories


Wiring accessories
Product description: Wiring accessory 4 Poles; potmeter (Bulk pack). FOR: S4962


45900419-039

Honeywell Electronic accessories


Wiring accessories
Product description: Cable assembly (Bulk pack). FOR: C7195A2/B/C


45900421-001

Honeywell Orifice for pilotburner


NATURAL GAS H
Product description: 0,38+0,36 A; 17 mbar (Bulk pack). FOR: Q359A


45900421-002

Honeywell Orifice for pilotburner


NATURAL GAS H
Product description: 0,56+0,41 A; 17 mbar (Bulk pack). FOR: Q359A


45900421-003

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,20+0,23 P; 28/37 mbar , Tubing 1/4"(4 mm) (Bulk pack). FOR: Q359A


45900421-006

Honeywell Orifice for pilotburner


NATURAL GAS H
Product description: 0,53+0,41 A; 20 mbar, Tubing 6 mm (4 mm) (Bulk pack). FOR: Q349C, Q359B


45900421-009

Honeywell Orifice for pilotburner


NATURAL GAS H/L
Product description: 0,56+0,42 A; -H:20mbar, -L:25mbar, Tubing 6 mm (4 mm) (Bulk pack). -H: FOR Q334A, Q349A, Q371A, Q389A, Q395A. -L: FOR Q389A


45900421-010

Honeywell Orifice for pilotburner


NATURAL GAS H/L
Product description: 0,38+0,36 A; -H:20mbar, -L:25mbar Tubing 6 mm (4 mm) (Bulk pack). -H: FOR Q389A, Q395A. -L: FOR Q359A, Q385A


45900421-011

Honeywell Orifice for pilotburner


NATURAL GAS H/L
Product description: 0,56+0,42 A; -H:20mbar, -L:25mbar, Tubing 6 mm (4 mm) (Bulk pack). -H: FOR Q334A, Q349A, Q371A, Q389A, Q395A. -L FOR Q334A, Q349A, Q389A


45900421-012

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,20 P3; 28/37 mbar, Tubing 6 mm (4 mm) (Bulk pack). FOR: Q359A, Q385A


45900421-014

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,25 P; 28/37 mbar, Tubing 1/4"(4 mm), Tendency to softer flame (Bulk pack). FOR: C7034A, Q334A, Q349A, Q371A


45900421-015

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,25 P; 28/37 mbar, Tubing 1/4"(4 mm), Tendency to harder flame (Bulk pack). FOR: C7034A, Q334A, Q349A, Q371A


45900421-016

Honeywell Orifice for pilotburner


NATURAL GAS L
Product description: 0,51 A; 9 mbar, Tubing 1/4"(4 mm), Tendency to harder flame (Bulk pack). FOR: C7034A, Q334A, Q349A, Q371A


45900421-018

Honeywell Orifice for pilotburner


NATURAL GAS L
Product description: 0,51 A; 9 mbar, Tubing 1/4"(4 mm) (Bulk pack). FOR: C7034A, Q334A, Q349A, Q371A


45900421-020

Honeywell Orifice for pilotburner


NATURAL GAS H
Product description: 0,46 A; 9 mbar, Tubing 1/4"(4 mm) (Bulk pack). FOR: C7034A, Q334A, Q349A, Q371A


45900421-024

Honeywell Orifice for pilotburner


NATURAL GAS L
Product description: 0,38+0,36 A; 25 mbar, Tubing 1/4"(4 mm) (Bulk pack). FOR: Q359A, Q385A


45900421-029

Honeywell Orifice for pilotburner


NATURAL GAS H/L
Product description: 0,38+0,36 A; -H:20mbar, -L:25mbar, Tubing 6 mm (4 mm) (Bulk pack). -H: FOR Q389A, Q395A. -L: FOR Q359A, Q385A


45900421-030

Honeywell Orifice for pilotburner


NATURAL GAS L
Product description: 0,56+0,46 A; 25 mbar, Tubing 6 mm (4 mm) (Bulk pack). FOR: Q334A, Q349A, Q371A


45900421-032

Honeywell Orifice for pilotburner


NATURAL GAS H
Product description: 0,38+0,33 A; 20 mbar, Tubing 6 mm (4 mm) (Bulk pack). FOR: Q359A, Q385A


45900421-033

Honeywell Orifice for pilotburner


NATURAL GAS H/L
Product description: 0,33+0,30 A; -H:20mbar, -L:25mbar (Bulk pack). FOR: Q385A


45900421-034

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,20 P; 28/37 mbar, Tubing 6 mm (4 mm), Tendency to harder flame (Bulk pack). FOR: Q359A, Q385A, Q389A, Q395A


45900421-036

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,23 P; 28/37 mbar, Tubing 6 mm (4 mm) (Bulk pack). FOR: Q334A, Q349A, Q371A, Q389A


45900421-037

Honeywell Orifice for pilotburner


L.P.GAS
Product description: 0,20+0,23 P; 28/37 mbar, Tubing 6 mm (4 mm), Tendency to softer flame (Bulk pack). FOR: Q359A, Q385A


45900424-001

Honeywell Cover and Plug


Cover
Product description: Cover assy for first coil (1 hole) (Unit pack). FOR: VR46../86..


45900427-001

Honeywell Gas valve accessories


Knob / cap
Product description: Knob set (grey) (Bulk pack). FOR: V46../86..


45900427-010

Honeywell Gas valve accessories


Knob / cap
Product description: Knob base (Bulk pack). FOR: V46../86..


45900427-011

Honeywell Gas valve accessories


Knob / cap
Product description: Knob retainer (Bulk pack). FOR: V46../86..


45900427-012

Honeywell Gas valve accessories


Knob / cap
Product description: Knob base (Bulk pack). FOR: V46../86..


45900428-001

Honeywell Fittings and Adaptors


Adaptor
Product description: Switchable softlite adaptor: orifice 0,28 dia (Bulk pack). FOR: VR46../86


45900428-002

Honeywell Fittings and Adaptors


Adaptor
Product description: Switchable softlite adaptor: orifice 0,23 dia (Bulk pack). FOR: VR46../86, V(R)47../87


45900428-003

Honeywell Fittings and Adaptors


Adaptor
Product description: Switchable softlite adaptor: orifice 0,20 dia (Bulk pack). FOR: VR46../86


45900428-004

Honeywell Fittings and Adaptors


Adaptor
Product description: Switchable softlite adaptor: orifice 0,165 dia (Bulk pack). FOR: VR46../86


45900429-001

Honeywell Cover and Plug


Cover
Product description: Operator cover (H = 36 mm), 2 holes top exit + screw (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-007

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) + screw, Cable: 500mm + stripped end: 35mm, Wires: 4, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-008

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit inlet side) + screw, Cable: 500mm + stripped end: 35mm, Wires: 4, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-014

Honeywell Cover and Plug


Plug / connector
Product description: Plug 9 o`clock + screw, Cable: 500mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-015

Honeywell Cover and Plug


Plug / connector
Product description: Plug 12 o`clock + screw, Cable: 500mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-016

Honeywell Cover and Plug


Plug / connector
Product description: Plug single male + screw, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-018

Honeywell Cover and Plug


Cover
Product description: Operator cover (H = 36 mm), 1 hole top exit + screw, DIN faced V404/V804 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-019

Honeywell Cover and Plug


Plug / connector
Product description: Plug cable for high-low,12 o`clock + screw, Cable: 500mm + stripped end: 35mm, Wires: 3 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-020

Honeywell Cover and Plug


Plug / connector
Product description: Plug cable for high-low, 6 o`clock + screw, Cable: 800mm + stripped end: 35mm, Wires: 3 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-022

Honeywell Cover and Plug


Plug / connector
Product description: Plug 12 o`clock + screw, Cable: 800mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-025

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) + screw, Cable: 715mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-026

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) + screw, Cable: 500mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-028

Honeywell Cover and Plug


Plug / connector
Product description: Plug 9 o`clock + screw, Cable: 800mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-030

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outl.side) + screw, Cable: 700mm + stripped end: 35mm, Wires: 4, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-031

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outl.side) + screw, Cable: 552mm + stripped end: 25mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-036

Honeywell Cover and Plug


Plug / connector
Product description: Plug 12 o`clock (special) + screw, Cable: 720mm + stripped end: 30mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-037

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) (special) + screw, Cable: 730mm + stripped end: 30mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-039

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit inlet side) + screw, Cable: 750mm + stripped end: 35mm, Wires: 4, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-040

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) + screw, Cable: 900mm + stripped end: 80mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-041

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) + screw, Cable: 1000mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-044

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outl.side) + screw, Cable: 1000mm + stripped end: 35mm, Wires: 4, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-048

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit inlet side) + screw, Cable: 330mm + stripped end: 50mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-050

Honeywell Cover and Plug


Plug / connector
Product description: Plug cable, Cable: 735mm + stripped end: 35mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-051

Honeywell Cover and Plug


Cover
Product description: Cover with screw for gas pressure switch 45.900.438-1.. (Bulk pack). FOR: VK41../81..


45900429-053

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) + screw; customer special, Cable: 900mm + stripped end: 20mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-057

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit outlet side) (special) + screw, Cable: 640mm + stripped end: 30mm, Wires: 4, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900429-058

Honeywell Cover and Plug


Plug / connector
Product description: Plug cable for high-low, 6 o`clock + screw, Cable: 590mm + stripped end: 30mm, Wires: 3 (Bulk pack). FOR: V/VR49../89


45900429-059

Honeywell Cover and Plug


Cover
Product description: Operator cover (H = 26 mm), top exit + screw (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-060

Honeywell Cover and Plug


Cover
Product description: Operator cover (H = 26 mm), top exit + screw (Bulk pack). FOR: V44../88.., V46../86.., VR46../86.., V/VR49../89


45900429-065

Honeywell Cover and Plug


Plug / connector
Product description: Plug single (exit inlet side) + screw, Cable: 550mm + stripped end: 50mm, Wires: 3, DIN faced V404/V804 (Bulk pack). FOR: VR46../86..


45900431-004

Honeywell Gas valve accessories


Knob / cap
Product description: Cap with screw (ABS) (Bulk pack). FOR: S4565/4585


45900431-005

Honeywell Gas valve accessories


Knob / cap
Product description: Cap with screw (flame ret.) (Bulk pack). FOR: S4565/4585


45900431-009

Honeywell Gas valve accessories


Knob / cap
Product description: Cap for moduplus (Bulk pack). FOR: V7335/V7435


45900431-011

Honeywell Gas valve accessories


Knob / cap
Product description: Cap for moduplus (Bulk pack). FOR: V7335/V7435


45900431-014

Honeywell Gas valve accessories


Knob / cap
Product description: Cover CVBC (new housing) (Bulk pack). FOR: S49..


45900431-015

Honeywell Gas valve accessories


Knob / cap
Product description: Cap dust for pressure feedback connection (Bulk pack). FOR: VR46../86.., VK41../81.., V46../86..


45900438-101

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V (Unit pack). FOR: VR46../86..


45900438-104

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 250V (Bulk pack). FOR: VR46../86..


45900438-107

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V (Bulk pack). FOR: VK41../81..


45900438-109

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V (Bulk pack). FOR: VK41../81..


45900438-110

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V (Bulk pack). FOR: VK41../81..


45900438-112

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V (for VK41../81.. with venturi), SPDT switch (Bulk pack). FOR: VK41../81..


45900438-203

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 250V, cover mounted (Bulk pack). FOR: VR46../86..


45900438-204

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 250V, cover mounted (Bulk pack). FOR: VR46../86..


45900438-209

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V, cover mounted (Bulk pack). FOR: VK41../81..


45900438-213

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 250V, cover mounted (Bulk pack). FOR: VK41../81..


45900438-214

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 24V, cover mounted (Bulk pack). FOR: VK41../81..


45900438-301

Honeywell Gas valve accessories


Gas pressure switch
Product description: Gas pressure switch 250V adjustable (Bulk pack). FOR: VR46../86..


45900440-001

Honeywell Gas valve accessories


Other parts
Product description: Strain relief assy (Bulk pack). FOR: S4565/4585


45900441-011

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 145mm + stripped end: 75mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-012

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 24 V with Molex connector, Cable: 500mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-013

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 500mm + stripped end: 50mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-015

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 24 V, Cable: 500mm + stripped end: 50mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-016

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 240mm + stripped end: 150mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-017

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 150mm + stripped end: 40mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-018

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 800mm + stripped end: 40mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-019

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 24 V with AMP fastons, Cable: 50mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-021

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 24 V, Cable: 720mm + stripped end: 80mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-023

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 24 V, Cable: 1260mm + stripped end: 80mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-024

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 24 V with RAST5 connector, Cable: 1260mm + stripped end: 80mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-026

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 1500mm + stripped end: 50mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-029

Honeywell Cover and Plug


Plug / connector
Product description: Plug without rectifier (molded) 24 V, Cable: 500mm + stripped end: 50mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900441-030

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) without screw, Cable: 500mm + stripped end: 50mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-031

Honeywell Cover and Plug


Plug / connector
Product description: Plug with double rectifier (molded) , Cable: 650mm + stripped end: 50mm, Wires: 4 (Bulk pack). FOR: VK41../81..


45900441-035

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded), Cable: 570mm + stripped end: 470mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-039

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier (molded) 110 V, Cable: 500mm + stripped end: 50mm, Wires: 3 (Bulk pack). FOR: VK41../81..


45900441-040

Honeywell Cover and Plug


Plug / connector
Product description: Plug straight version (molded) 230 V ; Molex connector, Cable: 240mm, Wires: 5 (Bulk pack). FOR: VK41../81..


45900441-042

Honeywell Cover and Plug


Plug / connector
Product description: Plug with rectifier(molded) 230V; 2 leads; Molex conn.(cust spec), Cable: 75mm, Wires: 2 (Bulk pack). FOR: VK41../81..


45900442-001

Honeywell Gas valve accessories


Other parts
Product description: Cable grommet with hole (Bulk pack). FOR: S4565/4585


45900442-003

Honeywell Gas valve accessories


Other parts
Product description: Sleeve for ign. cable (Bulk pack). FOR: S4565/4585


45900442-007

Honeywell Gas valve accessories


Other parts
Product description: Gasket coil connection (Bulk pack). FOR: S4565/4585


45900442-010

Honeywell Gas valve accessories


Other parts
Product description: Grommet / Wire feed (Bulk pack). FOR: S4565/4585


45900442-011

Honeywell Gas valve accessories


Other parts
Product description: Gasket coil connection (Bulk pack). FOR: S4565/4585


45900444-001

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 56 kW (Bulk pack). FOR: VK41../81..


45900444-002

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold Quick Connect 40 kW (Bulk pack). FOR: VK41../81.., VK42/VK82


45900444-003

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold Quick Connect 27 kW (Bulk pack). FOR: VK41../81.., VK42/VK82


45900444-101

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Connection set valve/venturi (side outlet) (Bulk pack). FOR: VK41../81..


45900444-102

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Connection set valve/venturi (end outlet) (Bulk pack). FOR: VK41../81..


45900444-103

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Sealing ring valve/venturi (side outlet) (Bulk pack). FOR: VK41../81..


45900444-104

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan (Bulk pack). FOR: VK41../81.., VK42/VK82


45900444-105

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan (Bulk pack). FOR: VK41../81.., VK42/VK82


45900444-106

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Screw for fan/venturi only (Bulk pack). FOR: VK41../81.., VK42/VK82


45900444-107

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (5.2 dia) for valve/venturi code x02 (LP gas applications) (Bulk pack). FOR: VK41../81.., VK42/VK82


45900444-108

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan (Unit pack). FOR: VK41../81..


45900444-109

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (4.15 dia) for valve/venturi code x03 (LP gas applications) (Bulk pack). FOR: VK41../81..


45900444-110

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (6.0 dia) for valve/venturi code x01 (LP gas applications) (Bulk pack). FOR: VK41../81..


45900444-111

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (6.8 dia) for valve/venturi code x50 and x51 (LP gas applications) (Bulk pack). FOR: VK41../81..


45900444-113

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (4.4 dia) for valve/venturi code x53 (LP gas applications) (Bulk pack). FOR: VK41../81..


45900444-120

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (3.4 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-121

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (5.55 dia) for valve/venturi (Customer special) (Bulk pack). FOR: VK41../81..


45900444-122

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (5.55 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-123

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan with adhesive tape on one side (Bulk pack). FOR: VK41../81..


45900444-124

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (6.2 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-125

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan (customer special) (Bulk pack). FOR: VK41../81..


45900444-126

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan (customer special) (Bulk pack). FOR: VK41../81..


45900444-127

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Gasket venturi/fan (Bulk pack). FOR: VK41../81..


45900444-128

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (7.6 dia) for valve/venturi code x01 (LP gas applications) (Bulk pack). FOR: VK41../81..


45900444-129

Honeywell Venturies and Orifices


Connection set / gasket
Product description: Screw for mounting valve/venturi (Bulk pack). FOR: VK41../81..


45900444-130

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (3.1 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-131

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (4.55 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-132

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (5.25 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-133

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (7.8 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-134

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (8.0 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-135

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (4.75 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-136

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (3.90 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-137

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (5.70 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-138

Honeywell Venturies and Orifices


Orifice for valve / venturie
Product description: Orifice (5.90 dia) for valve/venturi (Bulk pack). FOR: VK41../81..


45900444-201

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 56 kW (Bulk pack). FOR: VK41../81..


45900444-202

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 40 kW (Bulk pack). FOR: VK41../81..


45900444-203

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 27 kW (Bulk pack). FOR: VK41../81..


45900444-302

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 40 kW (Customer special) (Unit pack). FOR: VK41../81..


45900444-402

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 40 kW (Customer special) (Unit pack). FOR: VK41../81..


45900444-502

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 40 kW (Customer special) (Unit pack). FOR: VK41../81..


45900444-702

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 40 kW (Customer special) (Bulk pack). FOR: VK41../81..


45900444-703

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 27 kW (Customer special) (Bulk pack). FOR: VK41../81..


45900444-803

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 27 kW (Customer special) (Bulk pack). FOR: VK41../81..


45900444-903

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 27 kW, screw adjustment sealed (Bulk pack). FOR: VK41../81..


45900445-007

Honeywell Gas valve accessories


Other parts
Product description: Screw for plug rectifier (45900441-xxx) (Bulk pack). FOR: VK41../81..


45900445-018

Honeywell Cover and Plug


Cover screw
Product description: Screw for cover assy first coil (Bulk pack). FOR: VR46../86..


45900445-024

Honeywell Gas valve accessories


Other parts
Product description: Cover softlite for CVI (Bulk pack). FOR: VK41../81..


45900445-025

Honeywell Gas valve accessories


Other parts
Product description: Outletscreen (Bulk pack). FOR: V46../86..


45900445-026

Honeywell Gas valve accessories


Other parts
Product description: Pressure test nipple (Bulk pack). FOR: VR46../86..


45900445-027

Honeywell Gas valve accessories


Other parts
Product description: Seal plate Venturi (Bulk pack). FOR: VK41../81..


45900446-050

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 82 kW (Bulk pack). FOR: VK41../81..


45900446-051

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 72 kW (Bulk pack). FOR: VK41../81..


45900446-052

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 46 kW (Bulk pack). FOR: VK41../81..


45900446-053

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold Quick Connect 34 kW (Bulk pack). FOR: VK41../81.., VK42/VK82


45900446-055

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold Quick Connect 16 kW (Bulk pack). FOR: VK41../81.., VK42/VK82


45900446-058

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 6 kW (Bulk pack). FOR: VK41../81..


45900446-250

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 82 kW (Bulk pack). FOR: VK41../81..


45900446-251

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 72 kW (Bulk pack). FOR: VK41../81..


45900446-252

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 46 kW (Bulk pack). FOR: VK41../81..


45900446-253

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold without gasket and screws 34 kW (Bulk pack). FOR: VK41../81..


45900446-350

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 82 kW, screw adjustment sealed (Bulk pack). FOR: VK41../81..


45900446-351

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 72 kW, screw adjustment sealed (Bulk pack). FOR: VK41../81..


45900446-355

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 16 kW with plate adjusted (Bulk pack). FOR: VK41../81..


45900446-453

Honeywell Venturies and Orifices


Venturie Manifold
Product description: Venturi manifold 34 kW, screw adjustment sealed (Bulk pack). FOR: VK41../81..


45900450-010

Honeywell Venturies and Orifices


Venturie medium sized
Product description: Venturi medium sized (VMS) (Bulk pack). FOR: VR46../86..


45900450-020

Honeywell Venturies and Orifices


Venturie medium sized
Product description: Venturi medium sized (VMS) (Bulk pack). FOR: VR46../86..


45900450-030

Honeywell Venturies and Orifices


Venturie medium sized
Product description: Venturi medium sized (VMS) (Bulk pack). FOR: VR46../86..


45900450-101

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 9.4 mm dia+O ring (Customer special) (Bulk pack). FOR: VR46../86..


45900450-102

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 8.4 mm dia+O ring (Customer special) (Bulk pack). FOR: VR46../86..


45900450-103

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 7.2 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-104

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 10.7 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-105

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 8.0 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-106

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 6.2 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-107

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 8.6 mm dia+O ring (Customer special) (Bulk pack). FOR: VR46../86..


45900450-108

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 9.8 mm dia+O ring (Customer special) (Bulk pack). FOR: VR46../86..


45900450-109

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 9.6 mm dia+O ring (Customer special) (Bulk pack). FOR: VR46../86..


45900450-110

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 9.4 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-111

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 6.7 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-112

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 8.4 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-114

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 9.2 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-115

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 7.0 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-116

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 8.8 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-117

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 9.0 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-118

Honeywell Venturies and Orifices


Orifice Venturi medium sized (VMS)
Product description: Orifice Venturi medium sized (VMS) 7.4 mm dia+O ring (Bulk pack). FOR: VR46../86..


45900450-210

Honeywell Venturies and Orifices


Venturie medium sized
Product description: Venturi medium sized (VMS); customer special (Bulk pack). FOR: VR46../86..


45900450-230

Honeywell Venturies and Orifices


Venturie medium sized
Product description: Venturi medium sized (VMS); customer special (Bulk pack). FOR: VR46../86..


45900450-310

Honeywell Venturies and Orifices


Venturie medium sized
Product description: Venturi medium sized (VMS); customer special (Bulk pack). FOR: VR46../86..


45900451-015

Honeywell Venturies and Orifices


Mini Venturi
Product description: Mini Venturi 15 kW + clip + O ring + O-ring (gas control connection) (Bulk pack). FOR: VK41../81..


45900451-025

Honeywell Venturies and Orifices


Mini Venturi
Product description: Mini Venturi 25 kW + clip + O ring + O-ring (gas control connection) (Bulk pack). FOR: VK41../81..


45900451-040

Honeywell Venturies and Orifices


Mini Venturi
Product description: Mini Venturi 40 kW + clip + O ring + O-ring (gas control connection) (Bulk pack). FOR: VK41../81..


45900451-225

Honeywell Venturies and Orifices


Mini Venturi
Product description: Mini Venturi 25 kW + clip + O ring + seal (pipe connection) (Bulk pack). FOR: VK41../81..


45900451-240

Honeywell Venturies and Orifices


Mini Venturi
Product description: Mini Venturi 40 kW + clip + O ring + seal (pipe connection) (Bulk pack). FOR: VK41../81..


45900451-256

Honeywell Venturies and Orifices


Mini Venturi
Product description: Mini Venturi 56 kW + clip + O ring + seal (pipe connection) (Bulk pack). FOR: VK41../81..


45900452-340

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 3.40 dia brass (Bulk pack). FOR: VK41../81..


45900452-420

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 4.20 dia brass (Bulk pack). FOR: VK41../81..


45900452-435

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 4.35 dia brass (Bulk pack). FOR: VK41../81..


45900452-475

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 4.75 dia brass (Bulk pack). FOR: VK41../81..


45900452-505

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 5.05 dia brass (Bulk pack). FOR: VK41../81..


45900452-535

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 5.35 dia brass (Bulk pack). FOR: VK41../81..


45900452-595

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 5.95 dia brass (Bulk pack). FOR: VK41../81..


45900452-605

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 6.05 dia brass (Bulk pack). FOR: VK41../81..


45900452-630

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 6.30 dia brass (Bulk pack). FOR: VK41../81..


45900452-755

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 7.55 dia brass (Bulk pack). FOR: VK41../81..


45900453-535

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 5.35 dia composite (Bulk pack). FOR: VK41../81..


45900453-595

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 5.95 dia composite (Bulk pack). FOR: VK41../81..


45900453-605

Honeywell Venturies and Orifices


Injector assy
Product description: Injector assy for pipe connection 6.05 dia composite (Bulk pack). FOR: VK41../81..


45900454-335

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 3.35 dia brass (Bulk pack). FOR: VK41../81..


45900454-340

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 3.40 dia brass (Bulk pack). FOR: VK41../81..


45900454-385

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 3.85 dia brass (Bulk pack). FOR: VK41../81..


45900454-390

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 3.90 dia brass (Bulk pack). FOR: VK41../81..


45900454-420

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.20 dia brass (Bulk pack). FOR: VK41../81..


45900454-430

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.30 dia brass (Bulk pack). FOR: VK41../81..


45900454-435

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.35 dia brass (Bulk pack). FOR: VK41../81..


45900454-440

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.40 dia brass (Bulk pack). FOR: VK41../81..


45900454-445

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.45 dia brass (Bulk pack). FOR: VK41../81..


45900454-475

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.75 dia brass (Bulk pack). FOR: VK41../81..


45900454-480

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 4.80 dia brass (Bulk pack). FOR: VK41../81..


45900454-515

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 5.15 dia brass (Bulk pack). FOR: VK41../81..


45900454-530

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 5.30 dia brass (Bulk pack). FOR: VK41../81..


45900455-335

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 3.35 dia composite (Bulk pack). FOR: VK41../81..


45900455-520

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 5.20 dia composite (Bulk pack). FOR: VK41../81..


45900455-615

Honeywell Venturies and Orifices


Orifice assembly Quick Connect outlet
Product description: Orifice assembly Quick Connect outlet 6.15 dia composite (Bulk pack). FOR: VK41../81..


45900456-215

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 2.15 dia brass (Bulk pack). FOR: VK41../81..


45900456-255

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 2.55 dia brass (Bulk pack). FOR: VK41../81..


45900456-275

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 2.75 dia brass (Bulk pack). FOR: VK41../81..


45900456-285

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 2.85 dia brass (Bulk pack). FOR: VK41../81..


45900456-295

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 2.95 dia brass (Bulk pack). FOR: VK41../81..


45900456-325

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.25 dia brass (Bulk pack). FOR: VK41../81..


45900456-335

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.35 dia brass (Bulk pack). FOR: VK41../81..


45900456-355

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.55 dia brass (Bulk pack). FOR: VK41../81..


45900456-370

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.70 dia brass (Bulk pack). FOR: VK41../81..


45900456-375

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.75 dia brass (Bulk pack). FOR: VK41../81..


45900456-380

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.80 dia brass (Bulk pack). FOR: VK41../81..


45900456-390

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.90 dia brass (Bulk pack). FOR: VK41../81..


45900456-395

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.95 dia brass (Bulk pack). FOR: VK41../81..


45900456-400

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.00 dia brass (Bulk pack). FOR: VK41../81..


45900456-425

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.25 dia brass (Bulk pack). FOR: VK41../81..


45900456-430

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.30 dia brass (Bulk pack). FOR: VK41../81..


45900456-440

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.40 dia brass (Bulk pack). FOR: VK41../81..


45900456-465

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.65 dia brass (Bulk pack). FOR: VK41../81..


45900456-470

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.70 dia brass (Bulk pack). FOR: VK41../81..


45900456-485

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.85 dia brass (Bulk pack). FOR: VK41../81..


45900456-490

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.90 dia brass (Bulk pack). FOR: VK41../81..


45900456-495

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.95 dia brass (Bulk pack). FOR: VK41../81..


45900456-505

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.05 dia brass (Bulk pack). FOR: VK41../81..


45900456-510

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.10 dia brass (Bulk pack). FOR: VK41../81..


45900456-515

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.15 dia brass (Bulk pack). FOR: VK41../81..


45900456-520

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.20 dia brass (Bulk pack). FOR: VK41../81..


45900456-540

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.40 dia brass (Bulk pack). FOR: VK41../81..


45900456-545

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.45 dia brass (Bulk pack). FOR: VK41../81..


45900456-560

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.60 dia brass (Bulk pack). FOR: VK41../81..


45900456-570

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.70 dia brass (Bulk pack). FOR: VK41../81..


45900456-580

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.80 dia brass (Bulk pack). FOR: VK41../81..


45900456-590

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.90 dia brass (Bulk pack). FOR: VK41../81..


45900456-605

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 6.05 dia brass (Bulk pack). FOR: VK41../81..


45900456-615

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 6.15 dia brass (Bulk pack). FOR: VK41../81..


45900456-620

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 6.20 dia brass (Bulk pack). FOR: VK41../81..


45900456-645

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 6.45 dia brass (Bulk pack). FOR: VK41../81..


45900456-685

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 6.85 dia brass (Bulk pack). FOR: VK41../81..


45900456-790

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 7.90 dia brass (Bulk pack). FOR: VK41../81..


45900457-300

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 3.00 dia composit (Bulk pack). FOR: VK41../81..


45900457-400

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 4.00 dia composit (Bulk pack). FOR: VK41../81..


45900457-560

Honeywell Venturies and Orifices


Orifice assembly 3/4 outlet
Product description: Orifice assembly 3/4 outlet 5.60 dia composit (Bulk pack). FOR: VK41../81..


45900459-003

Honeywell Venturies and Orifices


Mini Venturi Accessories
Product description: Mini Venturi Clip (gas pipe) (Bulk pack). FOR: VK41../81..


45900461-256

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi 56 kW + O ring (Bulk pack). FOR: VK45../85..


45900462-467

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi Injector assy for pipe connection 4.67 dia (brass) (Bulk pack). FOR: VK45../85..


45900462-480

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi Injector assy for pipe connection 4.80 dia (brass) (Bulk pack). FOR: VK45../85..


45900462-605

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi Injector assy for pipe connection 6.05 dia (brass) (Bulk pack). FOR: VK45../85..


45900463-236

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi 36 kW + O ring (Bulk pack). FOR: VK45../85..


45900463-256

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi 56 kW + O ring (Bulk pack). FOR: VK45../85..


45900463-280

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi 80 kW + O ring (Bulk pack). FOR: VK45../85..


45900466-002

Honeywell Elga


ELGA mini Venturie
Product description: ELGA Mini Venturi Cap Throttle (Bulk pack). FOR: VK45../85..


45900467-380

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 3.80 dia (composite) (Bulk pack). FOR: VK45../85..


45900467-450

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 4.50 dia (composite) (Bulk pack). FOR: VK45../85..


45900467-480

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 4.80 dia (composite) (Bulk pack). FOR: VK45../85..


45900467-530

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 5.30 dia (composite) (Bulk pack). FOR: VK45../85..


45900467-531

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 5.30 dia (composite) (Bulk pack). FOR: VK45../85..


45900467-580

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 5.80 dia (composite) (Bulk pack). FOR: VK45../85..


45900468-480

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 4.80 dia (composite) (Bulk pack). FOR: VK45../85..


45900468-560

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 5.60 dia (composite) (Bulk pack). FOR: VK45../85..


45900468-605

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 6.05 dia (composite) (Bulk pack). FOR: VK45../85..


45900468-660

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 6.60 dia (composite) (Bulk pack). FOR: VK45../85..


45900468-670

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 6.70 dia (composite) (Bulk pack). FOR: VK45../85..


45900468-740

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 7.40 dia (composite) (Bulk pack). FOR: VK45../85..


45900469-100

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 10.0 dia (composite) (Bulk pack). FOR: VK45../85..


45900469-560

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 5.60 dia (composite) (Bulk pack). FOR: VK45../85..


45900469-660

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 6.60 dia (composite) (Bulk pack). FOR: VK45../85..


45900469-710

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 7.10 dia (composite) (Bulk pack). FOR: VK45../85..


45900469-780

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 7.80 dia (composite) (Bulk pack). FOR: VK45../85..


45900469-810

Honeywell Elga


Elga Mini Venturie Restrictor
Product description: ELGA Mini Venturi Restrictor 8.10 dia (composite) (Bulk pack). FOR: VK45../85..


45900471-216B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 16 kW without throttle (Bulk pack). FOR: VK41../81..


45900471-216U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 16 kW without throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900471-227B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 27 kW without throttle (Bulk pack). FOR: VK41../81..


45900471-227U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 27 kW without throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900471-234B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 34 kW without throttle (Bulk pack). FOR: VK41../81..


45900471-234U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 34 kW without throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900471-240B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 40 kW without throttle (Bulk pack). FOR: VK41../81..


45900471-240U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 40 kW without throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900471-256B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 56 kW without throttle (Bulk pack). FOR: VK41../81..


45900471-256U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 56 kW without throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900472-216B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 16 kW with throttle (Bulk pack). FOR: VK41../81..


45900472-216U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 16 kW with throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900472-227B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 27 kW with throttle (Bulk pack). FOR: VK41../81..


45900472-227U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 27 kW with throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900472-234B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 34 kW with throttle (Bulk pack). FOR: VK41../81..


45900472-234U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 34 kW with throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900472-240B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 40 kW with throttle (Bulk pack). FOR: VK41../81..


45900472-240U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 40 kW with throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900472-256B

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 56 kW with throttle (Bulk pack). FOR: VK41../81..


45900472-256U

Honeywell Premix Engine


Premix Engine
Product description: Premix Engine Venturi manifold 56 kW with throttle (+O-ring and clips) (Unit pack). FOR: VK41../81..


45900473-001

Honeywell Premix Engine


Premix Engine Accessories
Product description: Premix Engine Clip Venturi-Fan (Bulk pack). FOR: VK41../81..


45900474-001

Honeywell Premix Engine


Premix Engine Accessories
Product description: Premix Engine Clip Venturi-Valve (Bulk pack). FOR: VK41../81.., VK42/VK82


45900475-001

Honeywell Premix Engine


Premix Engine Accessories
Product description: Premix Engine Seal Venturi-Valve (Bulk pack). FOR: VK41../81.., VK42/VK82


45900477-001

Honeywell Premix Engine


Premix Engine Accessories
Product description: Premix Engine Seal Venturi-Appliance (Bulk pack). FOR: VK41../81..


46176612-501

Honeywell Flame relays R4348
Accessories

Mounting and wiring sub base for panel mount



50017460-001/U

Honeywell Modutrol IV servo motors
Accessories

Internal multi tap transformer for use on 120 or 230Vac voltage or to provide galvanic insulation. 24/120/230V to 24V.



50023821-001/U

Honeywell Burner Controls EC/RM7800-series
Parts

Nema 4 cover assembly for remote mounting of S7800 display.



50023821-002/U

Honeywell Burner Controls EC/RM7800-series
Parts

Nema 4 cover assembly for remote mounting of S7800 display. Incl. remote reset button and wiring.



5017600

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 3/4"



5018000

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 1"



5018500

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 1 1/4"



5019100

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 1 1/2"



5021400

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 2"



5112-19/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement stem assembly for VBG valve, DN15, DN20



5112-20/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement stem assembly for VBG valve, DN25, DN32



5112-21/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN40, DN50 valves

Replacement stem assembly for VBG valve, DN40, DN50



5112-51/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN40, DN50 valves

Linkage set for VBG valves DN40, DN50 to M6061, M7061



5163000

Honeywell Controllable anti-pollution check valve EA type with union connectors, RV281
Spare parts

Union seal washer, 1 1/2"



5163100

Honeywell Controllable anti-pollution check valve EA type with union connectors, RV281
Spare parts

Union seal washer, 2"



5350000

Honeywell Water station, HS10S-FA
Spare parts

Lip seal ring, DN65



5350300

Honeywell Water station, HS10S-FA
Spare parts

Lip seal ring, DN80



5350400

Honeywell Water station, HS10S-FA
Spare parts

Lip seal ring, DN100



5350500

Honeywell Water station, HS10S-FA
Spare parts

Seal ring, DN65-100



5351200

Honeywell Controllable anti-pollution check valve EA type with union connectors, RV281
Spare parts

Union seal washer, 1/2"



5531500

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Disc guide 1"



5534900

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Disc guide 1/2"



5535100

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Disc guide 3/4"



5535300

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Disc guide 1 1/4"



5535500

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Disc guide 1 1/2"



5535700

Honeywell Controllable anti-pollution check valve EA type with internal thread, RV280
Spare parts

Disc guide 2"



5536400

Honeywell Reverse rinsing fine filter with clear filter bowl, F76CS
Spare Parts

Flange seal for sizes 3/4" - 1 1/4"



5585100

Honeywell Two-way control valve PN16, conical sealing DN15/20, V5822A
Accessories

Spare adjustment cap (pack of 10)



5605800

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN40



5605900

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Valve disc guide, DN50



5622100

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Ball valve



5707300

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN50



5707400

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN65



5707500

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN80



5707600

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN100



5707700

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN125



5707800

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN150



5707900

Honeywell Standard pattern pressure reducing valve with balanced seat, D15P
Spare Parts

Diaphragm for size DN200



5708000

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN50



5708100

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN65



5708200

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN80



5708300

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN100



5708400

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN125



5708500

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN150



5708600

Honeywell Low pressure pattern pressure Reducing Valve with Balanced Seat, D15NP
Spare Parts

Diaphragm for connection size DN200



5726800

Honeywell Controllable anti-pollution check valve with flanges, RV283P
Spare Parts

Hexagonal blanking plug, DN40 - DN50



5782400

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 15



5782500

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 20



5782600

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 25



5782700

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 32



5782800

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 40



5782900

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 50



5783000

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 65



5783100

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 80



5783200

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 100



5783300

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 125



5783400

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 150



5783500

Honeywell Grey cast iron Y-strainer with flange connections, FY69P
Spare Parts

Cover plate seal for size DN 200



5783600

Honeywell Brass Y-strainer with threaded female connections, FY30
Spare Parts

Sealing ring for size 3/8"



5783800

Honeywell Cast steel Y-strainer with flange connections, FY71P
Spare Parts

Blanking plug seal ring, for size DN 100



5975900

Honeywell Reverse rinsing fine filter with rotatable connector piece, F74CS
Spare Parts

Flange seal for sizes 3/4" - 1 1/4"



600U

Honeywell Signal processors, single channel

Single channel input for S700/S800 viewing heads. And one model for flame detection with a flame rod.
Temperature range: 0...50C
Hardware outputs: Flame relay: 2 x SPDT
Self-check relay: 1 x SPDT
0..20 mA or 4..20 mA (selectable)

Model for flame detection by flame rod.
Product description: Flame monitoring system for use with a flame rod.
Supply voltage: 85..264 Vac


66-300

Honeywell Surge anticipating valve, PC300
Spare Parts

Replacement pilot valve for all sizes



70-550

Honeywell Filling valve, FV300
Accessories

Pilot float valve, level switching differential 5 - 160 cm, for all sizes



70-610

Honeywell Filling valve, FV300
Accessories

Pilot float valve, level switching differential 5 - 40 cm, for all sizes



700-1

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Swivel mount for S700/S800. 1" x 1/2" NPT



700-2

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Swivel mount for S700/S800. Flanged x 1/2" NPT



700-3

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Swivel mount for S700/S800. 1/2" x 1/2" NPT



700ACC

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

S700 cooling jacket for Vortex cooler



700ACSP

Honeywell Signal processors, single channel

Single channel input for S700/S800 viewing heads. And one model for flame detection with a flame rod.
Temperature range: 0...50C
Hardware outputs: Flame relay: 2 x SPDT
Self-check relay: 1 x SPDT
0..20 mA or 4..20 mA (selectable)

Standard models, 700xxSP series
Product description: Adjustable sensitivity signal processor for S700/S800
Supply voltage: 85..264 Vac


700CRLT

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Liquid tight cable restaint for S700/S800



700DA

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Delrin adapter replacement for S700. 1/2" NPT model



700DCSP

Honeywell Signal processors, single channel

Single channel input for S700/S800 viewing heads. And one model for flame detection with a flame rod.
Temperature range: 0...50C
Hardware outputs: Flame relay: 2 x SPDT
Self-check relay: 1 x SPDT
0..20 mA or 4..20 mA (selectable)

Standard models, 700xxSP series
Product description: Adjustable sensitivity signal processor for S700/S800
Supply voltage: 24 Vdc


700LTA

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Liquid tight cable adapter for S700/S800. 3/8" NPT model



700RAA

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Right angle adapter for S700/S800. 1/2" x 1/2" M/F



700UA

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Ultem heat insulating nipple for S700. 1/2" (view) - 1/4" air purge.



72710

Honeywell Electronic Spark Ignition generator, ZT93x-series
Accessories for ZT93x-series

High voltage silicone cable with 4 mm high voltage connector. Can be used with ZT93x-4 mm models. Diameter: 7 mm, standard length: 1000mm. Only available in pack size 25 pcs.



7271009

Honeywell Electronic Spark Ignition generator, ZT93x-series
Accessories for ZT93x-series

High voltage silicone cable for ZT93x-1 mm models with 1 mm clip. Diameter: 7 mm, standard length: 1000mm. Only available in pack size 25 pcs.



7283001

Honeywell Electronic Spark Ignition generator, ZT93x-series
Accessories for ZT93x-series

Power supply cable, with moulded connector. For all ZT93x models, standard length: 300mm. Only available in pack size 25 pcs.



74993U

Honeywell Electronic Spark Ignition generator, ZT93x-series
Accessories for ZT93x-series

Bag containing 100pcs high voltage insulation and fixation clips for ZT93x-1mm models, for use with universal 7 mm high voltage cable.



76-600

Honeywell Attitude control valve, FD300
Spare Parts

Replacement pilot valve for all sizes



7616BR/U

Honeywell Fluid power actuators for safety shut-off gas valve VE5000-series
Accessories

Damper Crank Arm (damper arm and clip)



7617ADW/U

Honeywell Modutrol IV servo motors
Accessories

Cranc arm assembly short



78-LKS160-81U

Honeywell Servo motors for industrial butterfly and throttle valves

The MT4000, MF4000 and LKS160 are non-spring return motors used to control dampers and valves.
The motors are used for damper and valve control in industrial burner applications.
Approvals: CE, AGA
Ambient temperature: -40...60C
Maximum humidity: 90%rh
Input signal: SPDT
Angle of rotation: 90o
End switches: 3

LKS160 for use with VT5000 throttle valves
Supply voltage: 230 Vac
Runtime: 34s
Torque: 3Nm
Model: A5-34 S8.P1.1
Setpoint potentiometer: 1k
Shaft mounting: 8 mm round
Protection class: IP40


800DA

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Delrin adapter replacement for S800. 1/2" model.



800UA

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Mounting

Ultem heat insulating nipple for S800. 1/2" (view) - 1/4" air purge.



A152-1/2AA

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 6 bar, for size 1/2"



A152-1/2AB

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 8 bar, for size 1/2"



A152-1/2AC

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 10 bar, for size 1/2"



A152-1AA

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 6 bar, for size 1"



A152-1AB

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 8 bar, for size 1"



A152-1AC

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 10 bar, for size 1"



A152-3/4AA

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 6 bar, for size 3/4"



A152-3/4AB

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 8 bar, for size 3/4"



A152-3/4AC

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 10 bar, for size 3/4"



A160-11/4AA

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 6 bar, for size 1 1/4"



A160-11/4AB

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 8 bar, for size 1 1/4"



A160-11/4AC

Honeywell Diaphragm safety valve for drinking water systems, SM152
Spare Parts

Valve insert, set pressure 10 bar, for size 1 1/4"



A162-BA

Honeywell SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162
Spare Parts

Safety valve exchange, set pressure 6 bar, for size 1/2"



A162-BC

Honeywell SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162
Spare Parts

Safety valve exchange, set pressure 10 bar, for size 1/2"



A4021A1002

Honeywell Valve proving system A4021

The A4021 is a self-checking microprocessor based Valve Proving System (VPS). The A4021 checks the effective closure of automatic shut-off valves by measuring the pressure. differential between two valves during the test sequence.
The A4021 is specially designed to be used as proving system to check the effective closure of the valves before burner start up (pre-configuration) or at the end of a heat demand (post-configuration).
Approvals: CE approved (50Hz) according EN1643 (PIN: CE-0063AS1822)
Protection class: IP40, only with subbase ZL030001
Ambient temperature: -10...60C
Maximum humidity: 95%rh
Remote reset.
Alarm output potential free NO contact.
Uses the NO contact of a standard gas pressure switch, that is set to 1/2x the nominal inlet pressure.
Suggested gas pressure switches: C6097 series C60VR40xxx series
Outputs: 1xSPST
Operation: Automatic
Runtime: 60s
Comment: Test time per valve 25sec.


A4021A1010

Honeywell Valve proving system A4021

The A4021 is a self-checking microprocessor based Valve Proving System (VPS). The A4021 checks the effective closure of automatic shut-off valves by measuring the pressure. differential between two valves during the test sequence.
The A4021 is specially designed to be used as proving system to check the effective closure of the valves before burner start up (pre-configuration) or at the end of a heat demand (post-configuration).
Approvals: CE approved (50Hz) according EN1643 (PIN: CE-0063AS1822)
Protection class: IP40, only with subbase ZL030001
Ambient temperature: -10...60C
Maximum humidity: 95%rh
Remote reset.
Alarm output potential free NO contact.
Uses the NO contact of a standard gas pressure switch, that is set to 1/2x the nominal inlet pressure.
Suggested gas pressure switches: C6097 series C60VR40xxx series
Outputs: 1xSPST
Operation: Automatic
Runtime: 60s
Comment: Test time per valve 25sec.


AA76-1/2A

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Drain connector for sizes 1/2" - 2"



AC-15FS

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

Soldering fitting for DN15 valve, pipe size 12 mm



AC-15FT

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN15 valve, pipe size R3/8"



AC-15TF

Honeywell Two-way control valve PN16, external threaded connections DN15-50, V5011E
Accessories

Internal threaded fitting for DN15 valve pipe size Rp 1/2"



AC-15TF-1

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Internal threaded fitting for VBG DN15 valve, pipe size Rp 1/2"



AC-20FS

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

Soldering fitting for DN20 valve, pipe size 15 mm



AC-20FT

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN20 valve, pipe size R1/2"



AC-20TF

Honeywell Two-way control valve PN16, external threaded connections DN15-50, V5011E
Accessories

Internal threaded fitting for DN20 valve pipe size Rp 3/4"



AC-25T

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN25 valve, pipe size R1"



AC-25TF

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN25 valve, pipe size Rp1"



AC-32T

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN32 valve, pipe size R11/4"



AC-32TF

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN32 valve, pipe size Rp11/4"



AC-40T

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN40 valve, pipe size R11/2"



AC-40TF

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN40 valve, pipe size Rp11/2"



AC-50TF

Honeywell Two-way control valve PN16, external threaded connections DN15-50, V5011E
Accessories

Internal threaded fitting for DN50 valve pipe size Rp 2"



ACC400

Honeywell Lyric T6 Smart Thermostat
Accessories for wall mounted Lyric

Large cover plate



ACC55XBE

Honeywell Industrial flame monitoring - Viewing Heads
Parts and accessories: Mounting

Air cooling canister for S550xBE viewing heads. 1/4 inch air inlet port. Use with vortex coolers. Not for older S5xx and S550BE-EX models.



ACC90

Honeywell TheraPro HR90 Electronic Radiator Controller
Accessories

Cable to copy time program HR90 to other HR90 devices



ACH28

Honeywell RF Electronic radiator controller HR92
Valve adapters

Comap/Herz M28x1,5



ACN-15C

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Compression fitting for DN15 valve, pipe size 15 mm



ACN-15S

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Soldering fitting for DN15 valve, pipe size 12 mm



ACN-15T

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN15 valve, pipe size R3/8"



ACN-20C

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Compression fitting for DN20 valve, pipe size 22 mm



ACN-20S

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Soldering fitting for DN20 valve, pipe size 15 mm



ACN-20T

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN20 valve, pipe size R1/2"



ACN-25T

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN25 valve, pipe size R1"



ACS-15T

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

External threaded fitting for DN15 valve, pipe size R1/2"



ACS-15W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN15 valve, pipe size 1/2"



ACS-20T

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

External threaded fitting for DN20 valve, pipe size R3/4"



ACS-20W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN20 valve, pipe size 3/4"



ACS-25T

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN25 valve, pipe size R1"



ACS-25W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN25 valve, pipe size 1"



ACS-32T

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

External threaded fitting for DN32 valve, pipe size R1 1/4"



ACS-32W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN32 valve, pipe size 1 1/4"



ACS90

Honeywell RF Electronic radiator controller HR92
Accessories

Cable for window contact HCA30



AD300-1/2

Honeywell Electronic refill unit, NK300T
Accessories

Adapter to fit the softening unit to a 3/4" male connection.



AE295D

Honeywell Backflow Preventer with integrated shut-off facility, BA295D-AS/ASC
Spare parts

Replacement unit - brass



AE295D-C

Honeywell Retrofit Backflow Preventer for tap fittings and armatures, BA295D-WH/WHS/WHD
Spare parts

Replacement unit - chrome plated



AE295STN-11/2A

Honeywell Backflow Preventer for standpipes, BA295STN-A
Spare parts

Shutoff facility complete



AEL-222200

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 0,7
Model: AEL 0.5


AEL-222201

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 1,0
Model: AEL 1.0


AEL-222202

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 2,0
Model: AEL 2.0


AEL-222203

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 3
Model: AEL 3.0


AEL-222204

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 3,5
Model: AEL 4.0


AEL-222210

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 0,7
Model: AEL 0.5


AEL-222211

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 1,0
Model: AEL 1.0


AEL-222212

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 2,0
Model: AEL 2.0


AEL-222213

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 3
Model: AEL 3.0


AEL-222214

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves without Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 3,5
Model: AEL 4.0


AEL-B2200

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 0,7
Model: AEL 0.5


AEL-B2201

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 1,0
Model: AEL 1.0


AEL-B2202

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 2,0
Model: AEL 2.0


AEL-B2204

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 6mm
Outlet ODF: 10mm
Evaporating pressure range: 1...7bar
Orifice size: 3,5
Model: AEL 4.0


AEL-B2210

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 0,7
Model: AEL 0.5


AEL-B2212

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 2,0
Model: AEL 2.0


AEL-B2213

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 3
Model: AEL 3.0


AEL-B2214

Honeywell Series AEL - Automatic Expansion Valves with fixed orifice and internal pressure equalisation

Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable evaporating pressure setting
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Maximum pressure PS 25.5 bar(a)
Maximum test pressure PF 28 bar(a)
Special versions (bypass, other refrigerants, etc.) on request
Series: AEL
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, head
Copper parts: connection tube
Max. ambient temperature: 100C
Thermal charge: All CFC, HCFC, HFC, not for ammonia.
Factory setting: 2.2bar
Download PDF with Series number in Table

Automatic Expansion Valves with Bypass
Inlet ODF: 1/4"
Outlet ODF: 3/8"
Evaporating pressure range: 1...7bar
Orifice size: 3,5
Model: AEL 4.0


AF00-B54

Honeywell Outdoor temperature sensor, Pt1000

Approvals: IEC751 class B
Temperature element: Pt1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2
Protection class: IP54


AF10-B54

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC10k
Protection class: IP54


AF11DS-1/2A

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Filter insert complete for filters with Double Spin Technology, filter mesh size 100 micron, for sizes 1/2" - 3/4"



AF11DS-1A

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Filter insert complete for filters with Double Spin Technology, filter mesh size 100 micron, for sizes 1" - 1 1/4"



AF11S-1/2A

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Filter insert complete, filter mesh size 100 micron, for sizes 1/2" - 3/4"



AF11S-1/2B

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 20 micron, for size 1/2" - 3/4"



AF11S-1/2C

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 50 micron, for size 1/2" - 3/4"



AF11S-1/2D

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 200 micron, for size 1/2" - 3/4"



AF11S-1/2E

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 300 micron, for size 1/2" - 3/4"



AF11S-1/2F

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 500 micron, for size 1/2" - 3/4"



AF11S-11/2A

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Filter insert complete, filter mesh size 100 micron, for sizes 1 1/2" - 2"



AF11S-11/2B

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 20 micron, for size 1 1/2" - 2"



AF11S-11/2C

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 50 micron, for size 1 1/2" - 2"



AF11S-11/2D

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 200 micron, for size 1 1/2" - 2"



AF11S-11/2E

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 300 micron, for size 1 1/2" - 2"



AF11S-11/2F

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 500 micron, for size 1 1/2" - 2"



AF11S-1A

Honeywell Reverse rinsing fine filter, F76S
Spare Parts

Filter insert complete, filter mesh size 100 micron, for sizes 1" - 1 1/4"



AF11S-1B

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 20 micron, for size 1" - 1 1/4"



AF11S-1C

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 50 micron, for size 1" - 1 1/4"



AF11S-1D

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 200 micron, for size 1" - 1 1/4"



AF11S-1E

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 300 micron, for size 1" - 1 1/4"



AF11S-1F

Honeywell Filter combination with reverse rinsable fine filter, clear filter bowl and balanced-seat pressure reducing valve, FK09S
Spare Parts

Filter insert complete, filter mesh size 500 micron, for size 1" - 1 1/4"



AF20-B54

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP54


AF20-B65

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP65


AF70-1A

Honeywell Retrofit fine filter for rotatable connector flange, FN70C
Spare Parts

Filter insert complete, filter mesh size 100 micron for sizes 3/4" - 1 1/4"



AF74-1A

Honeywell Reverse rinsing fine filter with rotatable connector piece, F74CS
Spare Parts

Filter insert complete, filter mesh size 100 micron for sizes 1/2" - 1 1/4"



AF74-1C

Honeywell Reverse rinsing fine filter with rotatable connector piece, F74CS
Spare Parts

Filter insert complete, filter mesh size 50 micron for sizes 1/2" - 1 1/4"



AF74-1D

Honeywell Reverse rinsing fine filter with rotatable connector piece, F74CS
Spare Parts

Filter insert complete, filter mesh size 200 micron for sizes 1/2" - 1 1/4"



AF78TS-065A

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 100 micron, for size DN 65



AF78TS-065C

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 50 micron, for size DN 65



AF78TS-065D

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 200 micron, for size DN 65



AF78TS-080A

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 100 micron, for size DN 80



AF78TS-080C

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 50 micron, for size DN 80



AF78TS-080D

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 200 micron, for size DN 80



AF78TS-100A

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 100 micron, for size DN 100



AF78TS-100C

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 50 micron, for size DN 100



AF78TS-100D

Honeywell Reverse rinsing fine filter with flanges, F78TS
Spare parts

Filter insert complete, filter mesh 200 micron, for size DN 100



AFA90

Honeywell RF Electronic radiator controller HR92
Accessories

Dial with chromed cap (3 pieces in one pack)



AGF1

Honeywell Flue gas temperature sensor

Steel plug in temperature sensor with mounting flange.
For flue gas temperature measurement.
Temperature element: Pt1000
Temperature range: 0...320C
Media temp. limit: temperatures up to 400 oC are allowable for short periods
Supplied with electrical cable with steel casing.
Mounting place: flue gas vent
Immersion depth: 120mm
Cable length: 1m


AK-NK300

Honeywell Refilling combination, NK300S
Accessories

Replacement kit NK300 Replacement kit when exchanging NK300 against NK300S



AKA3

Honeywell Heating, District Heating and Multi-Fuel OTC Controller, SMILE
Accessories for models with boiler burner output

Cable accessory



AMV-00002

Honeywell Series AMV - Automatic Expansion Valves with interchangeable orifice cartridges

Series AMV Automatic Expansion Valves Interchangeable orifice cartridge, adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AMV are used in general refrigeration and for original equipment. For plants like dehumidifiers, air driers, water coolers, icemaking machines or air conditioners.
AMV : with internal pressure equalisation; for single injection in installations with one or more cooling circuits
AMVX: with external pressure equalisation; for optimal evaporation effectiveness in all applications. Obligatory for multiple injection by liquid distributors
Adjustable evaporating pressure setting 0.5 bar within the evaporating pressure range
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Special versions (bypass, other refrigerants, etc.) on request
For capacities of orifices download attached engineering manual or check with our selection software Valve Tool
Series: AMVX
Orifice: interchangeable
Connections: flare x flare
Pressure equalizer: internal, X-model: external
Balanced port: no
Capillary tube length: 1.5m
Brass parts: body
Stainless steel parts: internals, thermal head
Copper parts: connection tubes, bulb
Max. ambient temperature: 100C
Thermal charge: all CFC, HCFC, HFC, not for ammonia
Download PDF with Series number in Table

AMV - Automatic Expansion Valves with internal pressure equalisation
Inlet UNF: 5/8"
Outlet UNF: 3/4"
Press equal: no
Evaporating pressure range: 2.5...3.5bar
Factory setting: 3bar


AMV-00003

Honeywell Series AMV - Automatic Expansion Valves with interchangeable orifice cartridges

Series AMV Automatic Expansion Valves Interchangeable orifice cartridge, adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AMV are used in general refrigeration and for original equipment. For plants like dehumidifiers, air driers, water coolers, icemaking machines or air conditioners.
AMV : with internal pressure equalisation; for single injection in installations with one or more cooling circuits
AMVX: with external pressure equalisation; for optimal evaporation effectiveness in all applications. Obligatory for multiple injection by liquid distributors
Adjustable evaporating pressure setting 0.5 bar within the evaporating pressure range
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Special versions (bypass, other refrigerants, etc.) on request
For capacities of orifices download attached engineering manual or check with our selection software Valve Tool
Series: AMVX
Orifice: interchangeable
Connections: flare x flare
Pressure equalizer: internal, X-model: external
Balanced port: no
Capillary tube length: 1.5m
Brass parts: body
Stainless steel parts: internals, thermal head
Copper parts: connection tubes, bulb
Max. ambient temperature: 100C
Thermal charge: all CFC, HCFC, HFC, not for ammonia
Download PDF with Series number in Table

AMV - Automatic Expansion Valves with internal pressure equalisation
Inlet UNF: 5/8"
Outlet UNF: 3/4"
Press equal: no
Evaporating pressure range: 3.5...4.5bar
Factory setting: 4bar


AMV-00004

Honeywell Series AMV - Automatic Expansion Valves with interchangeable orifice cartridges

Series AMV Automatic Expansion Valves Interchangeable orifice cartridge, adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AMV are used in general refrigeration and for original equipment. For plants like dehumidifiers, air driers, water coolers, icemaking machines or air conditioners.
AMV : with internal pressure equalisation; for single injection in installations with one or more cooling circuits
AMVX: with external pressure equalisation; for optimal evaporation effectiveness in all applications. Obligatory for multiple injection by liquid distributors
Adjustable evaporating pressure setting 0.5 bar within the evaporating pressure range
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Special versions (bypass, other refrigerants, etc.) on request
For capacities of orifices download attached engineering manual or check with our selection software Valve Tool
Series: AMVX
Orifice: interchangeable
Connections: flare x flare
Pressure equalizer: internal, X-model: external
Balanced port: no
Capillary tube length: 1.5m
Brass parts: body
Stainless steel parts: internals, thermal head
Copper parts: connection tubes, bulb
Max. ambient temperature: 100C
Thermal charge: all CFC, HCFC, HFC, not for ammonia
Download PDF with Series number in Table

AMV - Automatic Expansion Valves with internal pressure equalisation
Inlet UNF: 5/8"
Outlet UNF: 3/4"
Press equal: no
Evaporating pressure range: 4.5...5.5bar
Factory setting: 5bar


AMVX-00002

Honeywell Series AMV - Automatic Expansion Valves with interchangeable orifice cartridges

Series AMV Automatic Expansion Valves Interchangeable orifice cartridge, adjustable evaporating pressure
Automatic expansion valves (constant pressure valves) series AMV are used in general refrigeration and for original equipment. For plants like dehumidifiers, air driers, water coolers, icemaking machines or air conditioners.
AMV : with internal pressure equalisation; for single injection in installations with one or more cooling circuits
AMVX: with external pressure equalisation; for optimal evaporation effectiveness in all applications. Obligatory for multiple injection by liquid distributors
Adjustable evaporating pressure setting 0.5 bar within the evaporating pressure range
Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas
Special versions (bypass, other refrigerants, etc.) on request
For capacities of orifices download attached engineering manual or check with our selection software Valve Tool
Series: AMVX
Orifice: interchangeable
Connections: flare x flare
Pressure equalizer: internal, X-model: external
Balanced port: no
Capillary tube length: 1.5m
Brass parts: body
Stainless steel parts: internals, thermal head
Copper parts: connection tubes, bulb
Max. ambient temperature: 100C
Thermal charge: all CFC, HCFC, HFC, not for ammonia
Download PDF with Series number in Table

AMVX - Automatic Expansion Valves with external pressure equalisation
Inlet UNF: 5/8"
Outlet UNF: 3/4"
Press equal: 7/16"UNF
Evaporating pressure range: 2.5...3.5bar
Factory setting: 3bar


AOV30

Honeywell evohome, colour screen multi-zone controller with remote access
Radiator componenets

Valve adapter M30x1,0



APS90

Honeywell RF Electronic radiator controller HR92
Accessories

Power module for external power supply connection



AQS71-KAM-T

Honeywell Air duct CO2 and temperature transmitter

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Protection class: IP65 when probe mounted downwards, otherwise IP20
Output signal: The following output signals are applicable:
0..10 V for 0..2000 ppm CO2
0..10 V for 0..50 oC
Power supply: 24Vacdc
Mounting place: air duct
Wiring terminals: 5


AS06-1/2A

Honeywell Rinsable fine filter, MiniPlus-FF06
Spare Parts

Replacement sieve (5 pcs.), filter mesh 100 micron, for size 1/2"



AS06-1/2C

Honeywell Rinsable fine filter, MiniPlus-FF06
Spare Parts

Replacement sieve (5 pcs.), filter mesh 50 micron, for size 1/2"



AS06-1A

Honeywell Rinsable fine filter, MiniPlus-FF06
Spare Parts

Replacement sieve (5 pcs.), filter mesh 100 micron, for sizes 3/4" - 1 1/4"



AS06-1C

Honeywell Rinsable fine filter, MiniPlus-FF06
Spare Parts

Replacement sieve (5 pcs.), filter mesh 50 micron, for sizes 3/4" - 1 1/4"



AS100V

Honeywell T100V/T100VM Heavy-Duty Radiator Thermostat
Accessories

Screw lock, 5 pieces, for T100V-101 and T100V-241



AS100VM

Honeywell T100V/T100VM Heavy-Duty Radiator Thermostat
Accessories

Screw lock, 5 pieces, for T100VM-101 and T100VM-241



AS2

Honeywell Actuator for V5421B1090
Optional accessories

End switch



AS295D-C

Honeywell Backflow Preventer with integrated shut-off facility, BA295D-AS/ASC
Spare parts

Shutoff facility



AS60-Y

Honeywell Wellness water treatment, KaltecCool PW60
Accessories

Y-adapter for attachment to an already existing DA74C connection piece of a Honeywell filter; installation without having to open the pipe.



ASL453

Honeywell Electronical air flow switch for air (ASL)

Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit type ASL...
For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever flow processes in air or neutral gases have to be detected.
Protection class: sensor: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable from 0,1..20 m/s air speed
Media temperature at sensor: -20..100 oC.

Evaluation Unit
Mounting place: universal
Immersion depth: no
Power supply: 230Vac


ASL453/24

Honeywell Electronical air flow switch for air (ASL)

Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit type ASL...
For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever flow processes in air or neutral gases have to be detected.
Protection class: sensor: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable from 0,1..20 m/s air speed
Media temperature at sensor: -20..100 oC.

Evaluation Unit
Mounting place: universal
Immersion depth: no
Power supply: 24Vac


AST1

Honeywell Electronic thermostats (SmartTemp)
Accessories / Other

Wall mounting kit



ASW454

Honeywell Electronical flow switch for liquid (ASW)

The flow in fluids can be monitored reliably with flow sensors SWF62 and SWF62L and evaluation unit ASW454. The sensitivity can be adjusted accurately with a rough and fine potentiometer. The switching state is indicated by LED. The sensor element must be located in the flow.
Protection class: sensor: IP65; evaluation unit: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable, lowest 0,03 m/s fluid speed
For sensor:
media temperature 0..80 oC
sensing element steel

Evaluation unit
Power supply: 230Vac
Mounting place: universal
Immersion depth: no
Connection diameter: no


ASW454/24

Honeywell Electronical flow switch for liquid (ASW)

The flow in fluids can be monitored reliably with flow sensors SWF62 and SWF62L and evaluation unit ASW454. The sensitivity can be adjusted accurately with a rough and fine potentiometer. The switching state is indicated by LED. The sensor element must be located in the flow.
Protection class: sensor: IP65; evaluation unit: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable, lowest 0,03 m/s fluid speed
For sensor:
media temperature 0..80 oC
sensing element steel

Evaluation unit
Power supply: 24Vac
Mounting place: universal
Immersion depth: no
Connection diameter: no


ASY782

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Electrical

Connector cable with LED and 15-ft (4.5 m) cable with braided shield for S700/S800.



ASY784

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Electrical

Viewing head connector kit for S700/S800 without cable.



ASY785

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Electrical

Connector cable with LED and 50-ft (15 m)C330S cable with braided shield for S700/S800.



ASY785-200

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Electrical

Connector cable with LED and 200-ft (60 m)cable with braided shield for S700/S800.



ASYS55XBE

Honeywell Industrial flame monitoring - Viewing Heads
Parts and accessories: Electrical

C330S cable with connector for S55xBE series viewing heads, length 50 Ft / 15 m



ASYS55XBE-200

Honeywell Industrial flame monitoring - Viewing Heads
Parts and accessories: Electrical

C330S cable with connector for S55xBE series viewing heads, length 200 Ft / 60 m



ASYU2S

Honeywell Industrial flame monitoring - U2-101xS All-In-One Viewing head
Parts and accessories - 12 conductor C22S ITC/CIC approved cable for U2-S, with factory mounted R-518-10 connector

Cable length 50 Ft (15m )



ASYU2S-100

Honeywell Industrial flame monitoring - U2-101xS All-In-One Viewing head
Parts and accessories - 12 conductor C22S ITC/CIC approved cable for U2-S, with factory mounted R-518-10 connector

Cable length 100 Ft (30 m)



ASYU2S-200

Honeywell Industrial flame monitoring - U2-101xS All-In-One Viewing head
Parts and accessories - 12 conductor C22S ITC/CIC approved cable for U2-S, with factory mounted R-518-10 connector

Cable length 200 Ft (60 m)



ASYU2S-300

Honeywell Industrial flame monitoring - U2-101xS All-In-One Viewing head
Parts and accessories - 12 conductor C22S ITC/CIC approved cable for U2-S, with factory mounted R-518-10 connector

Cable length 50 Ft (90 m)



AT095

Honeywell Backflow preventer, BA095 BAmini
Spare Parts

Discharge connection



ATC928G2000

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Central controller (spare/system builder). Controller only.
Language option: EN/NL


ATC928G2019

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Central controller (spare/system builder). Controller only.
Language option: NL/FR


ATC928G2027

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Central controller (spare/system builder). Controller only.
Language option: DE/ES/IT


ATC928G3000

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Connected Central controller (spare/system builder).
Consists of: Controller ATC928
Language option: EN/NL/FR


ATC928G3026

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Connected Central controller (spare/system builder).
Consists of: Controller ATC928
Language option: CZ/HU/PL/RO/SK/DA


ATC928G3027

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Connected Central controller (spare/system builder).
Consists of: Controller ATC928
Language option: DE/IT/FR


ATF100

Honeywell evohome, colour screen multi-zone controller with remote access
Accessories for evohome

Table stand with power supply and EU power cord



ATF200

Honeywell evohome, colour screen multi-zone controller with remote access
Accessories for evohome

Table stand with power supply and UK power cord



ATF300

Honeywell evohome, colour screen multi-zone controller with remote access
Accessories for evohome

Wall pack with power supply



ATF400

Honeywell evohome, colour screen multi-zone controller with remote access
Accessories for evohome

3 interchangable front covers (polished black, brushed metal, high-gloss white)



ATF500DHW

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access
Stored hot water kit

Additional parts to add stored hot water to the system. It contains a Strap on sensor, Insertion sensor, RF- transmitter and BDR91 relay for valve control. This pack does not contain an evo controller.



ATF600

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access
Accessories for evohome

Evotouch wall mount kit (alternative to the table stand). Wall plate and power supply module



ATF700

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access
Accessories for evohome

Evotouch front covers. Three alternative colored covers.



ATF800

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access
Accessories for evohome

Evotouch Table stand. Table stand and power supply.



ATP921G2034

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Base pack (single zone chronotherm). Controller with BDR91 boiler relay, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP921G2042

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Base pack (single zone chronotherm). Controller with BDR91 boiler relay, table stand with plug.
Wiring connection: EU plug
Language option: DE/ES/IT


ATP921G2080

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Base pack (single zone chronotherm). Controller with BDR91 boiler relay, table stand with plug.
Wiring connection: UK plug
Language option: EN


ATP921R2100

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Connected pack (single zone with remote gateway). Controller with BDR91 boiler relay, remote gateway, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP921R2118

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Connected pack (single zone with remote gateway). Controller with BDR91 boiler relay, remote gateway, table stand with plug.
Wiring connection: EU plug
Language option: DE/ES/IT


ATP921R3052

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Base pack. Functions as a single zone programmable thermostat with connectivity (can be converted to zoning by adding system components).
Consists of: Controller ATC928, Table stand ATF800, RF Boiler relay BDR91
Language option: CZ/HU/PL/RO/SK/DA


ATP921R3100

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Base pack. Functions as a single zone programmable thermostat with connectivity (can be converted to zoning by adding system components).
Consists of: Controller ATC928, Table stand ATF800, RF Boiler relay BDR91
Language option: EN/NL/FR


ATP921R3118

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Base pack. Functions as a single zone programmable thermostat with connectivity (can be converted to zoning by adding system components).
Consists of: Controller ATC928, Table stand ATF800, RF Boiler relay BDR91
Language option: IT/ES


ATP921RM3118

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Connected pack OpenTherm, single zone
Consists of: Controller ATC928, Table stand ATF800, OpenTherm RF module R8810A108
Language option: NL/FR/EN


ATP924G2002

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone pack. Controller with 4x HR92, table stand with plug.
Wiring connection: EU plug
Language option: DE


ATP924G2010

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Base pack. Controller with BDR91 relay, 4x HR92WE, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP924G3002

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Heating pack
Consists of: Controller ATC928, 4x Radiator controller HR92, Table stand ATF800
Language option: DE/IT/ES


ATP924G3010

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Heating pack
Consists of: Controller ATC928, 4x Radiator controller HR92, RF Boiler relay BDR91, Table stand ATF800
Language option: NL/FR


ATP924G3020

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Heating pack
Consists of: Controller ATC928, 4x Radiator controller HR92WE, Table stand ATF800
Language option: DE/IT/ES


ATP924M3020

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Base pack OpenTherm pack
Consists of: Controller ATC928, 4x Radiator controller HR92, OpenTherm RF module R8810A1018, Table stand ATF800
Language option: NL/FR


ATP928G2074

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Underfloor pack (multi-zone). Controller with HCE80, HRA80, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP928G3074

Honeywell evohome, colour touch screen multi-zone central heating controller with remote access

The third generation of the Evotouch multi zone central heating control now with integrated Wifi allowing connectivity with the Total Connect Comfort Smart phone App.
The Evotouch central controller can operate twelve independent time and temperature controlled zones (rooms) plus a stored hot water system. Each zone has its own full seven day program with a range of overrides and One touch actions to make using the system fast and convenient.
The controller Evotouch is part of the evohome room control system and communicates wirelessly with radiator controllers, sensors and actuators with the proven 868 MHz wireless Ramses II RF technology. This allows the majority of heating systems to be upgraded with a minimum of disruption or re-wiring and is backward compatible with existing Honeywell Ramses II product.
Evohome can be remotely controlled via Android and Apple smartphones and linked to other Smart Home functionality using third party systems via IFTTT, Amazon Echo and Smartthings. It will control system with radiators, under floor heating, zone and mixing valves or a mixture of heating types in a home, office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive 11 language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers; available separately ATF700
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand allowing it to be used off the charging stand for a number of hours
http://getconnected.honeywell.com
ErP Class: VIII

Underfloor pack, multi-zone
Consists of: Controller ATC928, Controller floor heating HCE80, Antenna HRA80, Table stand ATF800
Language option: NL/FR


ATP951M2118

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Connected OpenTherm pack (single zone OpenTherm with gateway). Controller with RF bridge, Remote gateway, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP954M2020

Honeywell evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Base OpenTherm pack. Controller with RF bridge, 4x HR92WE, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATU2040A

Honeywell Rotary Actuator
Mounting kit for non-Honeywell valves

Universal kit for almost all valves



ATU2A

Honeywell Actuator for ZRK, and air-dampers
Mounting kit for Viessmann valves

Universal kit for Viessmann valves (DN50 or smaller; models 1965 or newer)



AVS90

Honeywell RF Electronic radiator controller HR92
Accessories

Vandalism protection



AVSOLAR-1/2

Honeywell Automatic air vent for solar installations, E121S
Accessories

Shutoff valve, Brass housing, high-grade, temperature-resistant plastic internal parts, hot water-resistant elastomer sealing ring, connection size 1/2"



AVSOLAR-3/8

Honeywell Automatic air vent for solar installations, E121S
Accessories

Shutoff valve, Brass housing, high-grade, temperature-resistant plastic internal parts, hot water-resistant elastomer sealing ring, connection size 3/8"



BA095-3/8E

Honeywell Backflow preventer, BA095 BAmini

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used mainly for OEM-applications, but can also be used for commercial and industrial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: ACS-certified, NF-certified
Optimal protection of the drinking water supply system
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass
Port connection: external threads
DN size: 10mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with external threads 1/2" on housing
Port diameter: 1/2inch


BA095-3/8EZ

Honeywell Backflow preventer, BA095 BAmini

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used mainly for OEM-applications, but can also be used for commercial and industrial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: ACS-certified, NF-certified
Optimal protection of the drinking water supply system
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass
Port connection: external threads
DN size: 10mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Special version with external threads 3/4" on housing
Port diameter: 3/4inch


BA195-1/2A

Honeywell Backflow preventer, BA195 miniBA

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used mainly for OEM-applications, but can also be used for commercial and industrial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Port diameter: 3/4inch
DN size: 10mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal


BA195-3/8E

Honeywell Backflow preventer, BA195 miniBA

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used mainly for OEM-applications, but can also be used for commercial and industrial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Port diameter: 3/4inch
DN size: 10mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal


BA295CS-1/2A

Honeywell Backflow preventer compact construction with integrated shut-off valves, BA295CS

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW, NF and WRAS approval requested for BA295S
Approved according to EN12729
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Integrated shut-off valves on inlet and outlet
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.5


BA295CS-11/2A

Honeywell Backflow preventer compact construction with integrated shut-off valves, BA295CS

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW, NF and WRAS approval requested for BA295S
Approved according to EN12729
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Integrated shut-off valves on inlet and outlet
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 14


BA295CS-11/4A

Honeywell Backflow preventer compact construction with integrated shut-off valves, BA295CS

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW, NF and WRAS approval requested for BA295S
Approved according to EN12729
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Integrated shut-off valves on inlet and outlet
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 9


BA295CS-1B

Honeywell Backflow preventer compact construction with integrated shut-off valves, BA295CS

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW, NF and WRAS approval requested for BA295S
Approved according to EN12729
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Integrated shut-off valves on inlet and outlet
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with threaded connections
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3.8


BA295CS-2A

Honeywell Backflow preventer compact construction with integrated shut-off valves, BA295CS

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW, NF and WRAS approval requested for BA295S
Approved according to EN12729
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Integrated shut-off valves on inlet and outlet
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 22


BA295CS-3/4A

Honeywell Backflow preventer compact construction with integrated shut-off valves, BA295CS

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW, NF and WRAS approval requested for BA295S
Approved according to EN12729
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Integrated shut-off valves on inlet and outlet
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.8


BA295D-1/2AS

Honeywell Backflow Preventer with integrated shut-off facility, BA295D-AS/ASC

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the water tapping of houshould outside garden taps or filling taps installations. They protect drinking water against fluids up to and including liquid category 4 acc. EN 1717.
Approvals: DVGW
Media: Drinking water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port diameter: 1/2inch
DN size: 10mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

rotatable, with integrated shutoff facility; with R1/2" (ISO 2999) threaded connection on inlet and G1" (ISO 228-1) threaded connection on outlet , 1" IG to 3/4" AG threaded adapter included
Body finishing: no


BA295D-1/2ASC

Honeywell Backflow Preventer with integrated shut-off facility, BA295D-AS/ASC

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the water tapping of houshould outside garden taps or filling taps installations. They protect drinking water against fluids up to and including liquid category 4 acc. EN 1717.
Approvals: DVGW
Media: Drinking water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port diameter: 1/2inch
DN size: 10mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

rotatable, with integrated shutoff facility and position indicator with R1/2" (ISO 2999)
Body finishing: chrome plated


BA295D-3/4WH

Honeywell Retrofit Backflow Preventer for tap fittings and armatures, BA295D-WH/WHS/WHD

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the water tapping of houshould taps, outside garden taps or filling taps. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approval for BA295D-WH/WHS. DVGW-approval for BA295D-WHD requested.
Highspeed maintenance: replacement kit, all BA functional parts in one housing, replacement/maintenance without time-consuming test procedure
Highspeed installation: easy and quick installation/ retrofit
Optimized outlet position, thereby bending of the connected flexible tube is prevented
Integral inlet strainer
Optimal protection of the drinking water supply system
Inlet check valve and discharge valve are combined in one cartridge
Rotatable housing - connection always in the right position
Minimal maintenance required, because the valve cartridge is completely replaceable
Low maintenance effort, because the strainer and the valve cartridge are completely replaceable without draining the system
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve sepa-rate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Each tapping can be protected separately
Media: Drinking water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port diameter: 3/4inch
DN size: 15mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

Standard version with G3/4" (ISO 228-1) threaded connection on inlet and G1" (ISO 228-1) threaded connection on outlet , 1" IG to 3/4" AG threaded adapter included, chrome plated, with discharge pipe connection
Outlet pressure: no


BA295D-3/4WHD

Honeywell Retrofit Backflow Preventer for tap fittings and armatures, BA295D-WH/WHS/WHD

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the water tapping of houshould taps, outside garden taps or filling taps. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approval for BA295D-WH/WHS. DVGW-approval for BA295D-WHD requested.
Highspeed maintenance: replacement kit, all BA functional parts in one housing, replacement/maintenance without time-consuming test procedure
Highspeed installation: easy and quick installation/ retrofit
Optimized outlet position, thereby bending of the connected flexible tube is prevented
Integral inlet strainer
Optimal protection of the drinking water supply system
Inlet check valve and discharge valve are combined in one cartridge
Rotatable housing - connection always in the right position
Minimal maintenance required, because the valve cartridge is completely replaceable
Low maintenance effort, because the strainer and the valve cartridge are completely replaceable without draining the system
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve sepa-rate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Each tapping can be protected separately
Media: Drinking water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port diameter: 3/4inch
DN size: 15mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

Standard Version with integrated pressure reducing valve, with G3/4" (ISO 228-1) threaded connection on inlet and G1" (ISO 228-1) threaded connection on outlet , 1" IG to 3/4" AG threaded adapter included, chrome plated, with discharge pipe connection
Outlet pressure: 1...4bar


BA295D-3/4WHS

Honeywell Retrofit Backflow Preventer for tap fittings and armatures, BA295D-WH/WHS/WHD

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the water tapping of houshould taps, outside garden taps or filling taps. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approval for BA295D-WH/WHS. DVGW-approval for BA295D-WHD requested.
Highspeed maintenance: replacement kit, all BA functional parts in one housing, replacement/maintenance without time-consuming test procedure
Highspeed installation: easy and quick installation/ retrofit
Optimized outlet position, thereby bending of the connected flexible tube is prevented
Integral inlet strainer
Optimal protection of the drinking water supply system
Inlet check valve and discharge valve are combined in one cartridge
Rotatable housing - connection always in the right position
Minimal maintenance required, because the valve cartridge is completely replaceable
Low maintenance effort, because the strainer and the valve cartridge are completely replaceable without draining the system
Optimized design prevents water stagnation
Compact construction
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve sepa-rate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Each tapping can be protected separately
Media: Drinking water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port diameter: 3/4inch
DN size: 15mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

Standard version with G1" (ISO 228-1) threaded connection on inlet and G1" (ISO 228-1) threaded connection on outlet
Outlet pressure: no


BA295I-1/2A

Honeywell Stainless Steel Backflow Preventer, BA295I

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DIN/DVGW-certified
Stainless steel construction
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version
Port diameter: 1inch
DN size: 15mm


BA295I-11/2A

Honeywell Stainless Steel Backflow Preventer, BA295I

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DIN/DVGW-certified
Stainless steel construction
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version
Port diameter: 2inch
DN size: 40mm


BA295I-11/4A

Honeywell Stainless Steel Backflow Preventer, BA295I

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DIN/DVGW-certified
Stainless steel construction
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version
Port diameter: 2inch
DN size: 32mm


BA295I-1A

Honeywell Stainless Steel Backflow Preventer, BA295I

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DIN/DVGW-certified
Stainless steel construction
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version
Port diameter: 1inch
DN size: 25mm


BA295I-2A

Honeywell Stainless Steel Backflow Preventer, BA295I

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DIN/DVGW-certified
Stainless steel construction
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version
Port diameter: 2inch
DN size: 50mm


BA295I-3/4A

Honeywell Stainless Steel Backflow Preventer, BA295I

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DIN/DVGW-certified
Stainless steel construction
Optimal protection of the drinking water supply network
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version
Port diameter: 1inch
DN size: 20mm


BA295S-1/2A

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1/2inch
DN size: 15mm
Max. media temperature: 65C
Flow capacity Kvs: 2.5


BA295S-1/2AGB

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (WRAS) with threaded connections
Port diameter: 1/2inch
DN size: 15mm
Max. media temperature: 60C
Flow capacity Kvs: 2.5


BA295S-11/2A

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1 1/2inch
DN size: 40mm
Max. media temperature: 65C
Flow capacity Kvs: 14


BA295S-11/2AGB

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (WRAS) with threaded connections
Port diameter: 11/2inch
DN size: 40mm
Max. media temperature: 60C
Flow capacity Kvs: 14


BA295S-11/4A

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1 1/4inch
DN size: 32mm
Max. media temperature: 65C
Flow capacity Kvs: 9


BA295S-11/4AGB

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (WRAS) with threaded connections
Port diameter: 11/4inch
DN size: 32mm
Max. media temperature: 60C
Flow capacity Kvs: 9


BA295S-1A

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 1inch
DN size: 25mm
Max. media temperature: 65C
Flow capacity Kvs: 6


BA295S-1AGB

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (WRAS) with threaded connections
Port diameter: 1inch
DN size: 25mm
Max. media temperature: 60C
Flow capacity Kvs: 6


BA295S-1B

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with threaded connections
Port diameter: 1inch
DN size: 25mm
Max. media temperature: 65C
Flow capacity Kvs: 3.8


BA295S-2A

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 2inch
DN size: 50mm
Max. media temperature: 65C
Flow capacity Kvs: 22


BA295S-2AGB

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (WRAS) with threaded connections
Port diameter: 2inch
DN size: 50mm
Max. media temperature: 60C
Flow capacity Kvs: 22


BA295S-3/4A

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (DVGW, NF) with threaded connections
Port diameter: 3/4inch
DN size: 20mm
Max. media temperature: 65C
Flow capacity Kvs: 3.8


BA295S-3/4AGB

Honeywell Backflow preventer compact construction with threaded connectors, BA295S

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approved
NF, WRAS, Belaqua, Kiwa, VA approval requested
Approved according to EN12729 except BA295S-1B
Optimal protection of the drinking water supply network
Integrated inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Low maintenance effort - cartridge insert and outlet check valve are completely replaceable
Optimized design prevents water stagnation
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Noise tested to class 2
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version (WRAS) with threaded connections
Port diameter: 3/4inch
DN size: 20mm
Max. media temperature: 60C
Flow capacity Kvs: 3.8


BA295STN-11/2A

Honeywell Backflow Preventer for standpipes, BA295STN-A

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the temporary water tapping of stand-pipes on events or construction sites.Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW-approval requested
Optimal protection of the drinking water supply system
Brass housing, lead-free
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construct
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Each tapping can be protected separately
Media: Water
Liquid category (EN1717): class 4
Body material: brass
Port connection: external threads
Port diameter: 1 1/2inch
DN size: 40mm
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal


BA295STN-3/4A

Honeywell Retrofit Backflow Preventer for standpipes, BA295STN

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used to protect the temporary water tapping of standpipes on events or construction sites. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW approved
Pivoted top connection
Optimal protection of the drinking water supply system
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construct
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Easy and quick installation
Each tapping can be protected separately
Seal-jacket to protect against manipulations
Easy maintenance due to upstream shut-off
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

Standard version, with threaded connections
Port diameter: 1inch
DN size: 20mm


BA295STN-3/4AC12

Honeywell Retrofit Backflow Preventer for standpipes, BA295STN

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used to protect the temporary water tapping of standpipes on events or construction sites. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW approved
Pivoted top connection
Optimal protection of the drinking water supply system
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construct
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Easy and quick installation
Each tapping can be protected separately
Seal-jacket to protect against manipulations
Easy maintenance due to upstream shut-off
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Port connection: external threads
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical

Housing chromium plated, with threaded connections
Port diameter: 3/4inch
DN size: 15mm


BA295STN-3/4WH

Honeywell Chromed Backflow Preventer for standpipes, BA295STN-WH

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
They are used to protect the water tapping of houshould taps, outside garden taps or filling taps. Fluids up to and including liquid category 4 to EN 1717 are protected.
Approvals: DVGW approved
Pivoted top connection
Optimal protection of the drinking water supply system
Integral inlet strainer
Inlet check valve and discharge valve are combined in one cartridge
Minimal maintenance required, because the valve cartridge is completely replaceable
Optimized design prevents water stagnation
Compact construct
Easy access to all internal components
Low pressure loss and high flow rate
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW recommendations for potable water
Easy and quick installation/retrofit
Each tapping can be protected separately
Easy maintenance due to upstream shut-off
Media: Water
Liquid category (EN1717): class 4
Body material: brass, dezincification resistant
Body finishing: chrome plated
Port connection: external threads
Port diameter: 3/4inch
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: vertical


BA298I-100FA

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. The stainless steel housing provides increased corrosion protection.
Approvals: DVGW, SVGW, WRC
European approvals in all connection sizes
Optimum protection of the drinking water supply system
Easy access to all inner components
Easy Maintenance due to optimized construction
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with PN 10 flanges
DN size: 100mm
Flow capacity Kvs: 85


BA298I-150FA

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. The stainless steel housing provides increased corrosion protection.
Approvals: DVGW, SVGW, WRC
European approvals in all connection sizes
Optimum protection of the drinking water supply system
Easy access to all inner components
Easy Maintenance due to optimized construction
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with PN 10 flanges
DN size: 150mm
Flow capacity Kvs: 191


BA298I-65FA

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. The stainless steel housing provides increased corrosion protection.
Approvals: DVGW, SVGW, WRC
European approvals in all connection sizes
Optimum protection of the drinking water supply system
Easy access to all inner components
Easy Maintenance due to optimized construction
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with PN 10 flanges
DN size: 65mm
Flow capacity Kvs: 45


BA298I-80FA

Honeywell Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. The stainless steel housing provides increased corrosion protection.
Approvals: DVGW, SVGW, WRC
European approvals in all connection sizes
Optimum protection of the drinking water supply system
Easy access to all inner components
Easy Maintenance due to optimized construction
Media: Water
Liquid category (EN1717): class 4
Body material: stainless steel
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with PN 10 flanges
DN size: 80mm
Flow capacity Kvs: 54


BA300-100A

Honeywell Backflow preventer with flanged connections, BA300

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.The powder coated ductile iron housing provides increased corrosion protection.
Approvals: DVGW, SVGW, ACS, NF, KIWA, WRAS, Belgaqua certification for all sizes.
Optimal protection of the drinking water supply system
Easy access to all internal components
Powder coated ductile iron housing gives increased corrosion protection
Easy Maintenance due to optimized construction
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Few individual parts
Light weight
Standardised discharge connection
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: ductile iron
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Mounting position: horizontal
Minimum inlet pressure: 1.5bar

Standard version with PN 10 flanges
DN size: 100mm
Flow capacity Kvs: 108


BA300-150A

Honeywell Backflow preventer with flanged connections, BA300

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.The powder coated ductile iron housing provides increased corrosion protection.
Approvals: DVGW, SVGW, ACS, NF, KIWA, WRAS, Belgaqua certification for all sizes.
Optimal protection of the drinking water supply system
Easy access to all internal components
Powder coated ductile iron housing gives increased corrosion protection
Easy Maintenance due to optimized construction
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Few individual parts
Light weight
Standardised discharge connection
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: ductile iron
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Mounting position: horizontal
Minimum inlet pressure: 1.5bar

Standard version with PN 10 flanges
DN size: 150mm
Flow capacity Kvs: 190.9


BA300-200A

Honeywell Backflow preventer with flanged connections, BA300

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.The powder coated ductile iron housing provides increased corrosion protection.
Approvals: DVGW, SVGW, ACS, NF, KIWA, WRAS, Belgaqua certification for all sizes.
Optimal protection of the drinking water supply system
Easy access to all internal components
Powder coated ductile iron housing gives increased corrosion protection
Easy Maintenance due to optimized construction
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Few individual parts
Light weight
Standardised discharge connection
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: ductile iron
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Mounting position: horizontal
Minimum inlet pressure: 1.5bar

Standard version with PN 10 flanges
DN size: 200mm
Flow capacity Kvs: 339.3


BA300-65A

Honeywell Backflow preventer with flanged connections, BA300

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.The powder coated ductile iron housing provides increased corrosion protection.
Approvals: DVGW, SVGW, ACS, NF, KIWA, WRAS, Belgaqua certification for all sizes.
Optimal protection of the drinking water supply system
Easy access to all internal components
Powder coated ductile iron housing gives increased corrosion protection
Easy Maintenance due to optimized construction
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Few individual parts
Light weight
Standardised discharge connection
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: ductile iron
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Mounting position: horizontal
Minimum inlet pressure: 1.5bar

Standard version with PN 10 flanges
DN size: 65mm
Flow capacity Kvs: 35.8


BA300-80A

Honeywell Backflow preventer with flanged connections, BA300

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.
Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.The powder coated ductile iron housing provides increased corrosion protection.
Approvals: DVGW, SVGW, ACS, NF, KIWA, WRAS, Belgaqua certification for all sizes.
Optimal protection of the drinking water supply system
Easy access to all internal components
Powder coated ductile iron housing gives increased corrosion protection
Easy Maintenance due to optimized construction
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Few individual parts
Light weight
Standardised discharge connection
Meets KTW recommendations for potable water
Media: Water
Liquid category (EN1717): class 4
Body material: ductile iron
Port connection: flanges
Max. media temperature: 65C
Nominal pressure: PN10
Mounting position: horizontal
Minimum inlet pressure: 1.5bar

Standard version with PN 10 flanges
DN size: 80mm
Flow capacity Kvs: 54.3


BACA-A

Honeywell Room Controller ComfortPoint Open
Tools for Commissioning

Wireless Adapter



BB051102DIN

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB051105DIN

Honeywell Solenoid gas valve, normally closed VE4000A3
Replacement coils

Replacement coil



BB051125

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB051126DIN

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB051152DIN

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB051154DIN

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB051181DIN

Honeywell Solenoid gas valve, normally closed VE4000A3
Replacement coils

Replacement coil



BB052301

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052302

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052303

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052306DIN

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052325

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052326DIN

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052340

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052365

Honeywell Solenoid gas valve, normally closed VE4000A1
Replacement coils

Replacement coil



BB052381DIN

Honeywell Solenoid gas valve, normally closed VE4000A3
Replacement coils

Replacement coil



BB052382DIN

Honeywell Solenoid gas valve, normally closed VE4000A3
Replacement coils

Replacement coil



BB151101

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB151104

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB151107

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB151107DIN

Honeywell Solenoid gas valve, normally closed, with characterized opening VE4000C1
Replacement coils

Replacement coil



BB151108

Honeywell Solenoid gas valve, normally closed, flanged connections VE4000B3
Replacement coils

Replacement coil



BB151125

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB151153

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB151180

Honeywell Solenoid gas valve, normally closed, flanged connections VE4000B3
Replacement coils

Replacement coil



BB152300

Honeywell Solenoid gas valve, normally closed VE4000A3
Replacement coils

Replacement coil



BB152301

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152302

Honeywell Solenoid gas valve, normally open VE4000S
Replacement coils

Replacement coil



BB152303

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152305

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152307

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152307DIN

Honeywell Solenoid gas valve, normally closed, with characterized opening VE4000C1
Replacement coils

Replacement coil



BB152324

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152325

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152326

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152340

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152342DIN

Honeywell Solenoid gas valve, normally closed, with characterized opening VE4000C1
Replacement coils

Replacement coil



BB152365

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152380

Honeywell Solenoid gas valve, normally closed, with flow rate adjustment VE4000B1
Replacement coils

Replacement coil



BB152382

Honeywell Solenoid gas valve, normally closed, flanged connections VE4000B3
Replacement coils

Replacement coil



BC1000A0110F

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

115Vac versions
Outputs: 1xSPST
Operation: Manual stop/start
Flame failure response time: 2s
Flame detector: Rectification
Supply voltage: 110..120 Vac
Comment: Flame rod (or C7012A/G)


BC1000A0110U

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

115Vac versions
Outputs: 1xSPST
Operation: Manual stop/start
Flame failure response time: 2s
Flame detector: UV
Supply voltage: 110..120 Vac
Comment: C7027, C7035, C7044


BC1000A0220F

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

230Vac versions
Outputs: 1xSPST
Operation: Manual stop/start
Flame failure response time: 2s
Flame detector: Rectification
Supply voltage: 220..240 Vac
Comment: Flame rod (or C7012A/G)


BC1000A0220U

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

230Vac versions
Outputs: 1xSPST
Operation: Manual stop/start
Flame failure response time: 2s
Flame detector: UV
Supply voltage: 220..240 Vac
Comment: C7027, C7035, C7044


BC1000B1000

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

115Vac versions
Outputs: 1xSPDT
Operation: Flame switch
Flame failure response time: <1s
Flame detector: Rectification
Supply voltage: 110..120 Vac
Comment: Flame rod (or C7012A/G)


BC1000B1018

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

230Vac versions
Outputs: 1xSPDT
Operation: Flame switch
Flame failure response time: <1s
Flame detector: Rectification
Supply voltage: 220..240 Vac
Comment: Flame rod (or C7012A/G)


BC1000B2001

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

115Vac versions
Outputs: 1xSPDT
Operation: Flame switch
Flame failure response time: <1s
Flame detector: UV
Supply voltage: 110..120 Vac
Comment: C7027, C7035, C7044


BC1000B2019

Honeywell Flame relays BC1000

The BC1000A/B series is a flame switch for intermittent operation to indicate presence or absence of a flame and to be applied in commercial or industrial burner installations.
The BC1000A is specially designed to be used as manual start/stop burnercontroller. For all type of burners with unlimited capacity.
Approvals: CE approved according EN298 (for intermittent operation), AGA
Protection class: IP00
Ambient temperature: -20...60C
Maximum humidity: 90%rh
BC1000A/B provides a Safe Start function which checks if a flame signal is present when applying power to the device.
BC1000A1/B1 models are for use with rectification type flame sensors, such as flame rods and C7012A/G UV sensors.
BC1000A2/B2 models are for use with Honeywell UV sensor models C7027, C7035 and C7044.
Note: The BC1000A1/B1 models will operate also with the "Satronic" IRD820/1020 range of infrared sensors. Note that this combination is NOT CE approved for use on installations that fall under the GAD (Gas Appliances Directive).

230Vac versions
Outputs: 1xSPDT
Operation: Flame switch
Flame failure response time: <1s
Flame detector: UV
Supply voltage: 220..240 Vac
Comment: C7027, C7035, C7044


BDR91A1000

Honeywell Single Zone Thermostat, TPI Control On/Off, Wireless, T87RF
For replacement or extension

Relay box



BDR91T1004

Honeywell Single Zone Thermostat, TPI Control On/Off, Wireless, T87RF
For replacement or extension

Relay box for UK



BS295STN-11/2A

Honeywell Backflow Preventer for standpipes, BA295STN-A
Accessories

Blind plug C-coupling with integrated test socket for checking standpipe-BA



BS300-1/2A

Honeywell Heatwater treatment unit, VE300S
Accessories

Blind plug for operating the system without a cartridge



BV10S-A

Honeywell Softening device KaltecSoft, KS10S
Spare parts

Bypass/blending valve for KS10S



BV300-100A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 100mm
Flow capacity Kvs: 167


BV300-150A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 150mm
Flow capacity Kvs: 407


BV300-200A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 200mm
Flow capacity Kvs: 676


BV300-250A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 250mm
Flow capacity Kvs: 1160


BV300-300A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 300mm
Flow capacity Kvs: 1600


BV300-350A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 350mm
Flow capacity Kvs: 1600


BV300-400A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 400mm
Flow capacity Kvs: 3300


BV300-450A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 450mm
Flow capacity Kvs: 3300


BV300-50A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 50mm
Flow capacity Kvs: 43


BV300-65A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 65mm
Flow capacity Kvs: 43


BV300-80A

Honeywell Basic valve, BV300

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.
High flow rate
Light weight and compact construction
Powder coated inside and outside - Powder used is physiologically and toxicologically safe
Media: Water
Body material: spherulitic cast iron GGG40
Body finishing: powder coating
Port connection: flanges
Max. media temperature: 80C
Nominal pressure: PN16
Minimum inlet pressure: 0.7bar

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request
DN size: 80mm
Flow capacity Kvs: 103


C22S

Honeywell Industrial flame monitoring - U2-101xS All-In-One Viewing head
Parts and accessories - 12 conductor C22S ITC/CIC approved cable for U2-S, with factory mounted R-518-10 connector

12 Conductor cable with braided shield. Orderable in 1 Ft (30.48 cm) incrementals, minimum length is 15 Ft.



C330S

Honeywell Industrial flame monitoring - S700/S800 Viewing Heads
Parts and accessories: Electrical

4 Conductor cable with braided shield, excl. connector. Orderable in 1 Ft (30.48 cm) incrementals, minimum length is 15 Ft.



C4065F1006

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065F.., SPST switch
Shape: C-C
Setting ON: 59+/-9Pa
Setting OFF: 44+/-12Pa
Setting Diff.: no
Micro Switch model: V-5620R-047


C4065FH1008

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: R-R
Setting ON: 101+/-10Pa
Setting OFF: 86+/-6Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5620RK-058


C4065FH1024

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: C-C
Setting ON: 52+/-8Pa
Setting OFF: min.36Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5620RK-058


C4065FH1032

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: R-R
Setting ON: 121+/-10Pa
Setting OFF: 106+/-6Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5620RK-058


C4065FH1040

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: R-R
Setting ON: 136+/-10Pa
Setting OFF: 121+/-6Pa
Setting Diff.: 15Pa
Micro Switch model: V-5620RK-058


C4065FH1065

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: C-C
Setting ON: 121+/-10Pa
Setting OFF: 105+/-6Pa
Setting Diff.: 16Pa
Micro Switch model: V-5620RK-058


C4065FH1099

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: C-C
Setting ON: 64+/-10Pa
Setting OFF: 48+/-6Pa
Setting Diff.: 16Pa
Micro Switch model: V-5620RK-058


C4065FH1131

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: R-R
Setting ON: 110+/-13Pa
Setting OFF: 95+/-10Pa
Setting Diff.: 15Pa
Micro Switch model: V-5620R-047


C4065FH2042

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: C-R
Setting ON: 108+/-10Pa
Setting OFF: 92+/-6Pa
Setting Diff.: Pa
Micro Switch model: V-5620RK-058


C4065FH2050

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: no
Setting ON: Pa
Setting OFF: Pa
Setting Diff.: Pa
Micro Switch model: no


C4065FH2066

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C4065FH.., SPST switch, enhanced setting accuracy
Shape: C-C
Setting ON: 90+/-13Pa
Setting OFF: 74+/-10Pa
Setting Diff.: 16Pa
Micro Switch model: V-5620RK-058


C6045D1019

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Direct mount on G1/4" connection
Pressure adjustment range: 5...50mbar
Max. pressure: 200mbar


C6045D1027

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Direct mount on G1/4" connection
Pressure adjustment range: 15...150mbar
Max. pressure: 300mbar


C6045D1043

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Direct mount on G1/4" connection
Pressure adjustment range: 0.2...3mbar
Max. pressure: 100mbar


C6045D1050

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Direct mount on G1/4" connection
Pressure adjustment range: 1...10mbar
Max. pressure: 100mbar


C6045D1068

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Including mounting bracket with screws
Pressure adjustment range: 0.2...3mbar
Max. pressure: 100mbar


C6045D1076

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Including mounting bracket with screws
Pressure adjustment range: 5...50mbar
Max. pressure: 200mbar


C6045D1084

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Including mounting bracket with screws
Pressure adjustment range: 15...150mbar
Max. pressure: 300mbar


C6045D1092

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Including mounting bracket with screws
Pressure adjustment range: 1...10mbar
Max. pressure: 100mbar


C6045D1100

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Including mounting bracket with screws and 2m (L) x 4mm (ID) tubing and nipples for air duct applications
Pressure adjustment range: 1...10mbar
Max. pressure: 100mbar


C6045D1118

Honeywell Pressure switch for general gas- and air application C6045D

For monitoring pressure of air and non-aggressive (fuel)gases.
Kind of pressure: differential pressure, relative
Pressure connection: positive pressure: G1/4"
negative pressure: G1/8"
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...70C
Ambient temperature: -15...70C
Switch function/capacity: SPDT Microswitch 250Vac; capacity: 2 A (inductive); 10 A resistive
Approvals: CE (EN1854) - PIN: 0063AR3085/2
Mounting position: horizontal or vertical
Large mambrane for maximum accuracy

Including mounting bracket with screws and 2m (L) x 4mm (ID) tubing and nipples for air duct applications
Pressure adjustment range: 0.2...3mbar
Max. pressure: 100mbar


C6065A1002

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 59+/-9Pa
Setting OFF: 44+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1010

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 88+/-9Pa
Setting OFF: 74+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1028

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: adj.39..98Pa
Setting OFF: no
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1036

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: adj.89..390Pa
Setting OFF: no
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065A1085

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 74+/-12Pa
Setting OFF: 59+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1093

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: L-C
Setting ON: 69+/-9Pa
Setting OFF: 54+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1135

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 51+/-12Pa
Setting OFF: 39+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1150

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 45+/-12Pa
Setting OFF: 30+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1168

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 39+/-9Pa
Setting OFF: 24+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1176

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: max.85Pa
Setting OFF: 62+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1192

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: L-C
Setting ON: 39+/-9Pa
Setting OFF: 24+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1226

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 78+/-12Pa
Setting OFF: 64+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1234

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 64+/-12Pa
Setting OFF: 49+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1267

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 121+/-22Pa
Setting OFF: 98+/-18Pa
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065A1275

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 78+/-15Pa
Setting OFF: 42+/-12Pa
Setting Diff.: adj.29..59Pa
Micro Switch model: V-5610RK


C6065A1291

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 118+/-18Pa
Setting OFF: 95+/-22Pa
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065A1309

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 74+/-12Pa
Setting OFF: 59+/-9Pa
Setting Diff.: 15Pa
Micro Switch model: V-5610R-041


C6065A1317

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: R-R
Setting ON: 78+/-9Pa
Setting OFF: 64+/-12Pa
Setting Diff.: 14Pa
Micro Switch model: V-5610R-041


C6065A1366

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: R-R
Setting ON: 59+/-9Pa
Setting OFF: 44+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1374

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: R-C
Setting ON: max.280Pa
Setting OFF: 220+/-20Pa
Setting Diff.: 55Pa
Micro Switch model: V-5610RK


C6065A1390

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: L-C
Setting ON: 49+/-12Pa
Setting OFF: 34+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1440

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 95+/-9Pa
Setting OFF: 81+/-12Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1473

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 110+/-12Pa
Setting OFF: 95+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065A1499

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: adj.98..290Pa
Setting OFF: no
Setting Diff.: 59Pa
Micro Switch model: V-5610RK


C6065A1507

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065A.., SPDT switch
Shape: C-C
Setting ON: 92+/-12Pa
Setting OFF: 78+/-9Pa
Setting Diff.: 14Pa
Micro Switch model: V-5610R-041


C6065AH1012

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.112Pa
Setting OFF: 82+/-6Pa
Setting Diff.: 15Pa
Micro Switch model: V-5610R-041


C6065AH1020

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 89+/-10Pa
Setting OFF: 74+/-6Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065AH1038

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 81+/-10Pa
Setting OFF: 66+/-6Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065AH1061

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 133+/-22Pa
Setting OFF: 110+/-15Pa
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065AH1079

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 73+/-10Pa
Setting OFF: 61+/-6Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065AH1087

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 103+/-10Pa
Setting OFF: 91+/-8Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065AH1095

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 214+/-12Pa
Setting OFF: 200+/-10Pa
Setting Diff.: 14Pa
Micro Switch model: V-5610R-041


C6065AH1103

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 49+/-10Pa
Setting OFF: 37+/-6Pa
Setting Diff.: 12Pa
Micro Switch model: V-5610R-041


C6065AH1111

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065AH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 68+/-10Pa
Setting OFF: 56+/-6Pa
Setting Diff.: 12Pa
Micro Switch model: V-5610R-041


C6065F1050

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: max.73Pa
Setting OFF: min.39Pa
Setting Diff.: adj.10..22Pa
Micro Switch model: V-5610R-041


C6065F1068

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: R-L
Setting ON: 64+/-12Pa
Setting OFF: 49+/-9Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065F1076

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: 88+/-9Pa
Setting OFF: 74+/-12Pa
Setting Diff.: 14Pa
Micro Switch model: V-5610R-041


C6065F1092

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: 54+/-12Pa
Setting OFF: 39+/-9Pa
Setting Diff.: adj.10..22Pa
Micro Switch model: V-5610R-041


C6065F1100

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: max.140Pa
Setting OFF: min.90Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065F1175

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: adj.39..98Pa
Setting OFF: no
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065F1183

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: adj.98..390Pa
Setting OFF: no
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065F1225

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: nom.100Pa
Setting OFF: min.66Pa
Setting Diff.: 24+/-8Pa
Micro Switch model: V-5610RK-061


C6065F1233

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: 160+/-15Pa
Setting OFF: 147+/-13Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065F1241

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: 165+/-15Pa
Setting OFF: 150+/-13Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065F1340

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: 30+/-9Pa
Setting OFF: min.10Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065F1357

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065F.., SPDT switch
Shape: C-C
Setting ON: 304+/-19Pa
Setting OFF: 281+/-15Pa
Setting Diff.: no
Micro Switch model: V-5610R-041


C6065FH1003

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.130Pa
Setting OFF: 105+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610D-045


C6065FH1011

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 139+/-10Pa
Setting OFF: 128+/-8Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1037

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: R-C
Setting ON: 73+/-15Pa
Setting OFF: 28+/-6Pa
Setting Diff.: 45Pa
Micro Switch model: V-5610RK


C6065FH1052

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 60+/-10Pa
Setting OFF: 48+/-6Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1078

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 118+/-22Pa
Setting OFF: 95+/-15Pa
Setting Diff.: 23Pa
Micro Switch model: V-5610R-041


C6065FH1086

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 48+/-10Pa
Setting OFF: 36+/-6Pa
Setting Diff.: 12Pa
Micro Switch model: V-5610R-041


C6065FH1094

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 213+/-22Pa
Setting OFF: 190+/-15Pa
Setting Diff.: 23Pa
Micro Switch model: V-5610R-041


C6065FH1102

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 53+/-10Pa
Setting OFF: 41+/-6Pa
Setting Diff.: 12Pa
Micro Switch model: V-5610R-041


C6065FH1128

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.176Pa
Setting OFF: 135+/-10Pa
Setting Diff.: 28+/-8Pa
Micro Switch model: V-5610RK-061


C6065FH1136

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.108Pa
Setting OFF: 72+/-6Pa
Setting Diff.: 27+/-7Pa
Micro Switch model: V-5610RK-061


C6065FH1144

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.96Pa
Setting OFF: 74+/-6Pa
Setting Diff.: 12+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1151

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 48+/-10Pa
Setting OFF: 36+/-6Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1185

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 138+/-13Pa
Setting OFF: 125+/-10Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1193

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 112+/-10Pa
Setting OFF: 100+/-6Pa
Setting Diff.: no
Micro Switch model: V-5610R-041


C6065FH1201

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-R
Setting ON: no
Setting OFF: 80+/-6Pa
Setting Diff.: 12+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1227

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 133+/-13Pa
Setting OFF: 120+/-10Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1235

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 153+/-13Pa
Setting OFF: 140+/-10Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1243

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 115+/-13Pa
Setting OFF: 102+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1250

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.176Pa
Setting OFF: 150+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1268

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 48+2/-10Pa
Setting OFF: 36+/-6Pa
Setting Diff.: 12Pa
Micro Switch model: V-5610R-041


C6065FH1292

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.130Pa
Setting OFF: min.100Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1375

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.55Pa
Setting OFF: min.35Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1383

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.74Pa
Setting OFF: min.54Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1391

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 152+/-13Pa
Setting OFF: 140+/-10Pa
Setting Diff.: 12Pa
Micro Switch model: V-5610R-041


C6065FH1417

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.128Pa
Setting OFF: min.100Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1474

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 68+/-10Pa
Setting OFF: 56+/-6Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1482

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 104+/-11Pa
Setting OFF: 92+/-8Pa
Setting Diff.: 13+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1516

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 48+/-10Pa
Setting OFF: 36+/-6Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1532

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 183+/-13Pa
Setting OFF: 170+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1540

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: R-C
Setting ON: 54+/-15Pa
Setting OFF: 16+/-8Pa
Setting Diff.: 38Pa
Micro Switch model: V-5610RK


C6065FH1557

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 367+/-19Pa
Setting OFF: 344+/-15Pa
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065FH1573

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 73+/-10Pa
Setting OFF: 61+/-6Pa
Setting Diff.: no
Micro Switch model: V-5610R-041


C6065FH1581

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-R
Setting ON: no
Setting OFF: 78+/-6Pa
Setting Diff.: 12+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1599

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-R
Setting ON: no
Setting OFF: 68+/-6Pa
Setting Diff.: 12+/-8Pa
Micro Switch model: V-5610R-041


C6065FH1623

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: L-C
Setting ON: 54+/-6Pa
Setting OFF: 42+/-10Pa
Setting Diff.: adj.7..22Pa
Micro Switch model: V-5610R-041


C6065FH1656

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 50+3/-10Pa
Setting OFF: 38+/-6Pa
Setting Diff.: adj.7..17Pa
Micro Switch model: V-5610R-041


C6065FH1664

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 470+/-22Pa
Setting OFF: 445+/-15Pa
Setting Diff.: adj.11..34Pa
Micro Switch model: V-5610R-041


C6065FH1698

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: max.192Pa
Setting OFF: 167+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610D-045


C6065FH1706

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 68+/-10Pa
Setting OFF: 56+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1714

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 650+/-60Pa
Setting OFF: min.550Pa
Setting Diff.: 44Pa
Micro Switch model: V-5610R-044


C6065FH1730

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 133+/-10Pa
Setting OFF: 120+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1748

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 328+/-19Pa
Setting OFF: 305+/-15Pa
Setting Diff.: 25Pa
Micro Switch model: V-5610R-041


C6065FH1755

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 65+/-10Pa
Setting OFF: 52+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1763

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 98+/-10Pa
Setting OFF: 85+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1771

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 103+/-10Pa
Setting OFF: 90+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1789

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 208+/-10Pa
Setting OFF: 195+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1797

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 45+/-10Pa
Setting OFF: 32+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1805

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 163+/-13Pa
Setting OFF: 150+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1813

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-R
Setting ON: 89+/-10Pa
Setting OFF: 74+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1821

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-R
Setting ON: 104+/-11Pa
Setting OFF: 92+/-8Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1839

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 213+/-13Pa
Setting OFF: 200+/-10Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH1854

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 60+/-10Pa
Setting OFF: 48+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065FH2010

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: no
Setting ON: no
Setting OFF: no
Setting Diff.: no
Micro Switch model: no


C6065FH2026

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065FH.., SPDT switch, enhanced setting accuracy
Shape: C-C
Setting ON: 133+/-10Pa
Setting OFF: 120+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065P1041

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065P..
Shape: C-C
Setting ON: 90+/-10Pa
Setting OFF: 77+/-6Pa
Setting Diff.: 13Pa
Micro Switch model: V-5610R-041


C6065P1098

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065P..
Shape: C-C
Setting ON: 214+/-12Pa
Setting OFF: 200+/-10Pa
Setting Diff.: no
Micro Switch model: V-5610R-041


C6065P1106

Honeywell Air Pressure Switch

Differential air pressure switch for forced flue combustion type burner system functions as a (combustion) airflow supervision with a safe start interlock.
Features:
Suitable for positive or negative pressure applications
Senses positive or negative differences from atmospheric
Pressure or in differential pressure up to 400 Pa
C6065 series can be used up to 90OC
The B at the end of the Typenumber may be replaced with a U, for a smaller amount of pieces.

C6065P..
Shape: C-C
Setting ON: 328+/-19Pa
Setting OFF: 305+/-15Pa
Setting Diff.: no
Micro Switch model: V-5610R-041


C6097A1004/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for pipe mount, G1/4" connection. Auto recycle. Break on pressure fall.
Pressure adjustment range: 1...12.5mbar
Differential pressure setpoint range: 6...10.5mbar
Max. pressure: 300mbar
Comment: CSA/UL/FM Approved


C6097A1012/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for pipe mount, G1/4" connection. Manual reset. Break on pressure fall.
Pressure adjustment range: 7...52mbar
Differential pressure setpoint range: 6...10.5mbar
Max. pressure: 500mbar
Comment: CSA/UL/FM Approved


C6097A1053/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for pipe mount, G1/4" connection. Auto recycle. Break on pressure fall.
Pressure adjustment range: 7...52mbar
Differential pressure setpoint range: 0.6...1.2mbar
Max. pressure: 600mbar
Comment: CSA/UL/FM Approved


C6097A1061/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for flange mount. Manual reset. Break on pressure fall.
Pressure adjustment range: 7...52mbar
Differential pressure setpoint range: 0.6...1.2mbar
Max. pressure: 600mbar
Comment: CSA/UL/FM Approved


C6097A1079/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for pipe mount, G1/4" connection. Auto recycle. Break on pressure fall.
Pressure adjustment range: 30...150mbar
Differential pressure setpoint range: 2.7...6mbar
Max. pressure: 600mbar
Comment: CSA/UL/FM Approved


C6097A2110

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for pipe mount, G1/4" connection. Uses PG11 cable gland.
Pressure adjustment range: 1...10mbar
Differential pressure setpoint range: ...0.4mbar
Max. pressure: 200mbar
Comment: CE Approved


C6097A2200

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for flange mount on valve body. Uses DIN connector (not included).
Pressure adjustment range: 2.5...50mbar
Differential pressure setpoint range: ...0.6mbar
Max. pressure: 300mbar
Comment: CE Approved


C6097A2210

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for pipe mount, G1/4" connection. Uses PG11 cable gland.
Pressure adjustment range: 2.5...50mbar
Differential pressure setpoint range: ...0.6mbar
Max. pressure: 300mbar
Comment: CE Approved


C6097A2300

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for flange mount on valve body. Uses DIN connector (not included).
Pressure adjustment range: 30...150mbar
Differential pressure setpoint range: ...2.8mbar
Max. pressure: 500mbar
Comment: CE Approved


C6097A2310

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for pipe mount, G1/4" connection. Uses PG11 cable gland.
Pressure adjustment range: 30...150mbar
Differential pressure setpoint range: ...2.8mbar
Max. pressure: 500mbar
Comment: CE Approved


C6097A2400

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for flange mount on valve body. Uses DIN connector (not included).
Pressure adjustment range: 100...500mbar
Differential pressure setpoint range: ...7mbar
Max. pressure: 600mbar
Comment: CE Approved


C6097A2410

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

European models for pipe mount, G1/4" connection. Uses PG11 cable gland.
Pressure adjustment range: 100...500mbar
Differential pressure setpoint range: ...7mbar
Max. pressure: 600mbar
Comment: CE Approved


C6097B1002/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for pipe mount, G1/4" connection. Manual reset. Break on pressure rise.
Pressure adjustment range: 30...150mbar
Differential pressure setpoint range: 25...30mbar
Max. pressure: 600mbar
Comment: CSA/UL/FM Approved


C6097B1101/U

Honeywell Pressure switch for general gas- and air application C6097

The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
Kind of pressure: differential pressure, relative
Pressure connection: Two models are available: pipe mount or flange mount on valve body.
Pipe mount models: positive pressure: G1/4"
Pipe mount models: negative pressure: G1/8"
Flange mount models: direct mount on valve body
Electrical connection: PG11 or DIN plug
Protection class: IP54
Housing material: Bottom part: aluminium die cast
Case: blue coloured polybutylene terephthalate
Cover: transparent polycarbonate
Media temp.: -15...80C
Ambient temperature: -15...60C
Switch function/capacity: Switch action: SPDT
Max voltage: 250Vac
Min voltage: 24Vac
Max resistive load: 5 A
Max inductive load (pf=0.6): 3 A
Min load: 50 mA
Approvals: C6097A1/B1 models: UL (US+C), CSA (US+C), FM
C6097A2 models: CE (EN1854) - PIN: 0063AR1571
Mounting position: horizontal or vertical
C6097A1 models are calibrated for pressure fall (approved for use as minimum pressure limiter in NA) and have psi or in.wc scale
C6097B1 models are calibrated for pressure rise (approved for use as maximum pressure limiter in NA) and have psi or in.wc scale
C6097A2 models are calibrated for nominal pressure (CE approved for use as minimum or maximum pressure limiter in EU) and have mbar scale

American models for pipe mount, G1/4" connection. Auto recycle. Break on pressure rise.
Pressure adjustment range: 103...480mbar
Differential pressure setpoint range: 7...21mbar
Max. pressure: 600mbar
Comment: CSA/UL/FM Approved


C60VR40040

Honeywell Pressure switch for gas application C60VR

Pressure switch for gas application to be mounted on VQ400 dual valves and VRB00/VR400/V4730 combination gas valves.
The C60VR40xxx has an adjustable setpoint and performs minimum gas pressure supervision in a safe start interlock circuit.
The C60VR40xxx is designed to be fitted directly on the valve body of the applicable gas valve body, using two mounting screws and an O-ring.
Kind of pressure: overpressure, relative
Pressure connection: Flanged, directly on valve body.
Electrical connection: DIN plug
Protection class: IP00 (IP54 with DIN plug mounted)
Housing material: Body: aluminium
Cover: reinforced PBT glassfibre
Ambient temperature: -10...70C
End switch function/capacity: Switch action: 1x SPDT
Resistive: 5A
Inductive (COS PHI = 0.6): 0.5A
Approvals: C60VR40 models: CE (EN 1854)
C60VRT40 models: UL
Mounting position: horizontal
DIN plug not included.
Comment: Max. pressure: 2 bar < 15 min

Models for Europe
Pressure adjustment range: 5...40mbar
Differential pressure: 1.5...2.5mbar
Max. pressure: 100mbar


C60VR40110

Honeywell Pressure switch for gas application C60VR

Pressure switch for gas application to be mounted on VQ400 dual valves and VRB00/VR400/V4730 combination gas valves.
The C60VR40xxx has an adjustable setpoint and performs minimum gas pressure supervision in a safe start interlock circuit.
The C60VR40xxx is designed to be fitted directly on the valve body of the applicable gas valve body, using two mounting screws and an O-ring.
Kind of pressure: overpressure, relative
Pressure connection: Flanged, directly on valve body.
Electrical connection: DIN plug
Protection class: IP00 (IP54 with DIN plug mounted)
Housing material: Body: aluminium
Cover: reinforced PBT glassfibre
Ambient temperature: -10...70C
End switch function/capacity: Switch action: 1x SPDT
Resistive: 5A
Inductive (COS PHI = 0.6): 0.5A
Approvals: C60VR40 models: CE (EN 1854)
C60VRT40 models: UL
Mounting position: horizontal
DIN plug not included.
Comment: Max. pressure: 2 bar < 15 min

Models for Europe
Pressure adjustment range: 30...110mbar
Differential pressure: 4...12mbar
Max. pressure: 600mbar


C60VRT40040

Honeywell Pressure switch for gas application C60VR

Pressure switch for gas application to be mounted on VQ400 dual valves and VRB00/VR400/V4730 combination gas valves.
The C60VR40xxx has an adjustable setpoint and performs minimum gas pressure supervision in a safe start interlock circuit.
The C60VR40xxx is designed to be fitted directly on the valve body of the applicable gas valve body, using two mounting screws and an O-ring.
Kind of pressure: overpressure, relative
Pressure connection: Flanged, directly on valve body.
Electrical connection: DIN plug
Protection class: IP00 (IP54 with DIN plug mounted)
Housing material: Body: aluminium
Cover: reinforced PBT glassfibre
Ambient temperature: -10...70C
End switch function/capacity: Switch action: 1x SPDT
Resistive: 5A
Inductive (COS PHI = 0.6): 0.5A
Approvals: C60VR40 models: CE (EN 1854)
C60VRT40 models: UL
Mounting position: horizontal
DIN plug not included.
Comment: Max. pressure: 2 bar < 15 min

Models for USA
Pressure adjustment range: 5...40mbar
Differential pressure: 1.5...2.5mbar
Max. pressure: 600mbar


C7008A1018/U

Honeywell Signal processors, single channel
Rectifying flame rod for 600U

Flame rod assembly. Electrode length: 305 mm (12")



C7008A1034/U

Honeywell Signal processors, single channel
Rectifying flame rod for 600U

Flame rod assembly. Electrode length: 610 mm (24")



C7012A1145/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for intermittent operation
Mechanical connection: 3/4" NPT
Ambient temperature: -4...79C
Protection class: IP66
Supply voltage: 110..120 Vac


C7012A1194/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for intermittent operation
Mechanical connection: 3/4" NPT
Ambient temperature: -4...79C
Protection class: IP66
Supply voltage: 240 Vac


C7012C1042/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

UL listed explosion proof models for intermittent operation
Mechanical connection: 1" NPT
Ambient temperature: -29...79C
Protection class: NEMA 7
Supply voltage: 110..120 Vac
Comment: Ex approved in USA only


C7012E1104/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for continuous operation (with mechanical shutter)
Mechanical connection: 3/4" NPT
Ambient temperature: -29...79C
Protection class: IP66
Supply voltage: 110..120 Vac
Note: Shutter coil voltage: 120V only


C7012E1120/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for continuous operation (with mechanical shutter)
Mechanical connection: 1" NPT
Ambient temperature: -40...79C
Protection class: IP66
Supply voltage: 110..120 Vac
Note: Shutter coil voltage: 120V only


C7012E1153/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for continuous operation (with mechanical shutter)
Mechanical connection: 3/4" NPT
Ambient temperature: -29...79C
Protection class: IP66
Supply voltage: 240 Vac
Note: Shutter coil voltage: 120V only


C7012E1187/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for continuous operation (with mechanical shutter)
Mechanical connection: 3/4" NPT
Ambient temperature: -29...79C
Protection class: IP66
Supply voltage: 220 Vac
Comment: "DIN" version
Note: Shutter coil voltage: 120V only


C7012E1195/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for continuous operation (with mechanical shutter)
Mechanical connection: 3/4" NPT
Ambient temperature: -29...79C
Protection class: IP66
Supply voltage: 110 Vac
Comment: "DIN" version
Note: Shutter coil voltage: 120V only


C7012F1052/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

UL listed explosion proof models for continuous operation (with mechanical shutter)
Mechanical connection: 1" NPT
Ambient temperature: -29...79C
Protection class: NEMA 7
Supply voltage: 110..120 Vac
Comment: Ex approved in USA only
Note: Shutter coil voltage: 120V only


C7012G1019/U

Honeywell UV flame sensors C7012A/C/E/F/G

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7012E/F models are approved for use in continuous operation, by using dynamic self-check.
C7012C/F models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models 1" NPT).
The "DIN" models have an additional grounding wire (green/yellow)
Cable length: 2.4m

Standard models for intermittent operation
Mechanical connection: 3/4" NPT
Ambient temperature: -4...79C
Protection class: IP66
Supply voltage: 220 Vac
Comment: "DIN" version


C7027A1023/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7027 with clamp type connector
Mechanical connection: 1/2"
Cable length: 2.4m
Ambient temperature: -18...102C
Protection class: IP54


C7027A1031/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7027 with clamp type connector
Mechanical connection: 1/2"
Cable length: 2.4m
Ambient temperature: -40...102C
Protection class: IP54


C7027A1049/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7027 with 1/2" NPT threaded spud connector
Mechanical connection: 1/2"
Cable length: 2.4m
Ambient temperature: -18...102C
Protection class: IP54


C7027A1056/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7027 with clamp type connector
Mechanical connection: 1/2"
Cable length: 2.4m
Ambient temperature: -18...102C
Protection class: IP54
Comment: "DIN/BG" model


C7027A1064/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7027 with 1/2" NPT threaded spud connector
Mechanical connection: 1/2"
Cable length: 7.3m
Ambient temperature: -40...102C
Protection class: IP54


C7035A1023/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7035 with field replaceable UV tube
Mechanical connection: 1"
Cable length: 1.8m
Ambient temperature: -18...121C
Protection class: IP67


C7035A1031/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7035 with field replaceable UV tube
Mechanical connection: 1"
Cable length: 1.8m
Ambient temperature: -40...121C
Protection class: IP67


C7035A1049/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7035 with field replaceable UV tube
Mechanical connection: 1" BSP
Cable length: 1.8m
Ambient temperature: -18...121C
Protection class: IP67
Comment: "DIN/BG" model


C7035A1056/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7035 with field replaceable UV tube
Mechanical connection: 1"
Cable length: 1.8m
Ambient temperature: -40...121C
Protection class: IP67


C7035A1064/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7035 with field replaceable UV tube
Mechanical connection: 1" BSP
Cable length: 1.8m
Ambient temperature: -40...121C
Protection class: IP67
Comment: "DIN/BG" model


C7035A1080/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7035 with field replaceable UV tube
Mechanical connection: 1"
Cable length: 1.8m
Ambient temperature: -18...121C
Protection class: IP67
Comment: High temp. wires (315C)


C7044A1006/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7044 for side or end viewing
Mechanical connection: mounting bracket
Cable length: 1.8m
Ambient temperature: -18...102C
Protection class: IP54


C7061A1004/U

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

European models for continuous operation, with mechanical shutter
Mechanical connection: 3/4" NPT
Cable length: 2.4m
Protection class: IP66
Comment: "DIN" model, with 5-wire cable
Note: Single shutter coil voltage: 120V only


C7061A1012/U

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

American models for continuous operation, with mechanical shutter
Mechanical connection: 3/4" NPT
Cable length: 2.4m
Protection class: IP66
Note: Single shutter coil voltage: 120V only


C7061A1020/U

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

European models for continuous operation, with mechanical shutter
Mechanical connection: 3/4" NPT
Cable length: 0m
Protection class: IP66
Note: Dual shutter coil voltage: 120/230V


C7061A1061/U

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

American models for continuous operation, with mechanical shutter
Mechanical connection: 3/4" NPT
Cable length: 2.4m
Protection class: IP66
Comment: With focussing lens
Note: Single shutter coil voltage: 120V only


C7061A1079/U

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

European models for continuous operation, with mechanical shutter
Mechanical connection: 3/4" NPT
Cable length: 0m
Protection class: IP66
Comment: With focussing lens
Note: Dual shutter coil voltage: 120/230V


C7061F1003

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

ATEX certified Ex-proof European models for continuous operation, with mechanical shutter (Ex: CENELEC II G Ex d IIC T6; zone 1&2)
Mechanical connection: 1" NPT
Cable length: 0m
Protection class: IP67
Comment: Incl. cable gland
Note: Dual shutter coil voltage: 120/230V


C7061F1011

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

KOSHA approved Ex-proof Korean models for continuous operation, with mechanical shutter (Ex: Ex d IIC T6 IP65)
Mechanical connection: 1" NPT
Cable length: 0m
Protection class: IP65
Comment: Ex-proof in Korea only
Note: Dual shutter coil voltage: 120/230V


C7061F2001/U

Honeywell UV flame sensors C7061A/F

Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
C7061-series models are approved for use in continuous operation, by using dynamic self-check.
C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2.
C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G.
Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
Quick and easy installation on standard 3/4" NPT sight pipe (Ex-proof models: 1" NPT).
Uses the same UV sensing ("Power") tube as used with C7027/35/44 series "MiniPeeper": no external power supply.
The "DIN" models have an additional grounding wire (green/yellow)
Ambient temperature: -40...80C

UL listed Ex-proof American models for continuous operation, with mechanical shutter (Ex: Class I, gr.C/D and Class II, gr.E/F/G)
Mechanical connection: 1" NPT
Cable length: 2.4m
Protection class: NEMA 7
Comment: Ex-proof in Americas only
Note: Single shutter coil voltage: 120V only


C7076A1007/U

Honeywell UV flame sensors C7076

UV flame sensor to detect ultraviolet radiation emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications, that use solid fuel or heavy oil, dirty gas, hydrogen, sulphur, etc. as fuel.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
Approved for use in continuous operation, by using dynamic self-check.
Integrated air purge connection.
Quick and easy installation on standard 1" NPT sight pipe.
Note: The C7076F models for use in hazardous areas are to be discontinued soon. Functional replacement is the Honeywell U2-101xS-PF series of combination flame sensors. For details, refer to the Industrial Flame Monitoring section from the start of the "Industrial Combustion" pages.
Spare parts for C7076F models remain available.
Mechanical connection: 1" NPT
Ambient temperature: -40...70C
Protection class: IP65
Note: Shutter coil voltage: 120V only

Standard enclosure (IP65)
Supply voltage: 110..120 Vac


C7076A1031/U

Honeywell UV flame sensors C7076

UV flame sensor to detect ultraviolet radiation emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications, that use solid fuel or heavy oil, dirty gas, hydrogen, sulphur, etc. as fuel.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
Approved for use in continuous operation, by using dynamic self-check.
Integrated air purge connection.
Quick and easy installation on standard 1" NPT sight pipe.
Note: The C7076F models for use in hazardous areas are to be discontinued soon. Functional replacement is the Honeywell U2-101xS-PF series of combination flame sensors. For details, refer to the Industrial Flame Monitoring section from the start of the "Industrial Combustion" pages.
Spare parts for C7076F models remain available.
Mechanical connection: 1" NPT
Ambient temperature: -40...70C
Protection class: IP65
Note: Shutter coil voltage: 120V only

Standard enclosure (IP65)
Supply voltage: 220..240 Vac


C7076F1006

Honeywell UV flame sensors C7076

UV flame sensor to detect ultraviolet radiation emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications, that use solid fuel or heavy oil, dirty gas, hydrogen, sulphur, etc. as fuel.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
Approved for use in continuous operation, by using dynamic self-check.
Integrated air purge connection.
Quick and easy installation on standard 1" NPT sight pipe.
Note: The C7076F models for use in hazardous areas are to be discontinued soon. Functional replacement is the Honeywell U2-101xS-PF series of combination flame sensors. For details, refer to the Industrial Flame Monitoring section from the start of the "Industrial Combustion" pages.
Spare parts for C7076F models remain available.
Mechanical connection: 1" NPT
Ambient temperature: -40...70C
Protection class: IP65
Note: Shutter coil voltage: 120V only

Ex-proof enclosure (ATEX: II G Ex d IIC T6 Zone 1&2)
Supply voltage: 220..240 Vac
Comment: Functional repl. U2-1016S-PF


C7076F1014

Honeywell UV flame sensors C7076

UV flame sensor to detect ultraviolet radiation emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications, that use solid fuel or heavy oil, dirty gas, hydrogen, sulphur, etc. as fuel.
Approvals: CE approved according to EN298 only in combination with matching Honeywell flame amplifiers and burner controls.
Approved for use in continuous operation, by using dynamic self-check.
Integrated air purge connection.
Quick and easy installation on standard 1" NPT sight pipe.
Note: The C7076F models for use in hazardous areas are to be discontinued soon. Functional replacement is the Honeywell U2-101xS-PF series of combination flame sensors. For details, refer to the Industrial Flame Monitoring section from the start of the "Industrial Combustion" pages.
Spare parts for C7076F models remain available.
Mechanical connection: 1" NPT
Ambient temperature: -40...70C
Protection class: IP65
Note: Shutter coil voltage: 120V only

Ex-proof enclosure (ATEX: II G Ex d IIC T6 Zone 1&2)
Supply voltage: 110..120 Vac
Comment: Functional repl. U2-1016S-PF


C7085A1006

Honeywell Air duct temperature sensor, average measurement

Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four rod clips with screws.
For application in ducts where large temperature gradients can occur.
The 3 meters flexible rod has four sensors positioned along the length of the rod.
Temperature element: 4 x Pt1000
Temperature range: -30...70C
Mounting place: air duct
Wiring terminals: 2


C7085A1014

Honeywell Air duct temperature sensor, average measurement, NTC

Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four rod clips with screws.
For application in ducts where large temperature gradients can occur.
The 3 meters flexible rod has four sensors positioned along the length of the rod.
Temperature element: 4 x NTC20k
Temperature range: -30...70C
Mounting place: air duct
Wiring terminals: 2


C7110A1010

Honeywell Air quality sensor

For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as furniture, carpets, paint, glue, etc.
Protection class: III as per EN60730-1I IP30 as per EN60529
Output signal: 0..10Vdc
Adjustable output offset and LED display
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7110C1001A

Honeywell Room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration in buildings.
LED functions: operation as CO2 indicator
Output signal: CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm
temperature: 0..10 V
Automatic baseline calibration, and quick calibration options.
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7110D1009A

Honeywell Room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
LED functions: operation as occupancy indicator
Output signal: CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm
Temperature setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.
Automatic baseline calibration, and quick calibration options.
Temperature element: NTC20k
Temperature range: 10...35C
Setpoint knob: -5...5C
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7927A1016/U

Honeywell UV flame sensors C7027/35/44 ("MiniPeeper")

Compact analogue UV flame sensor to detect ultraviolet radiations emitted by combustion flames.
Used with Honeywell burner controls to provide flame supervision for commercial and industrial burner applications.
Approvals: CE approved according to EN298, only in combination with matching Honeywell flame amplifiers and burner controls.
UL/CSA approved for USA, only in combination with matching Honeywell flame amplifiers and burner controls.
AGA approved for Australia, only in combination with matching Honeywell flame amplifiers and burner controls.
Only for intermittent operation. The burner has to recycle at least once per 24 hours.
Models marked "DIN Approved Model" have no CSA/UL marking on the product label and have an insulated cable instead of wires.
Maximum recommended cable length: ca. 50m
Features: Rugged, compact, with encapsulated sensing tube for maximum protection.
Quick and easy installation on standard sight pipe.
Detects UV radiation in the 310nm range of the spectrum.

C7927 solid state UV sensor (for EC/RM78xx only)
Mechanical connection: 1/2"
Cable length: 1.8m
Ambient temperature: -18...102C
Protection class: IP54
Comment: Not CE (EN298) approved.


CA295-1/2A

Honeywell Backflow preventer compact construction with threaded connectors, CA295

Backflow preventers are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 3 to EN 1717 are protected.
Approvals: KIWA-UK, KIWA, WRAS, BELGAQUA, NF, tested to EN 14367
Integral strainer
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate performance
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Media: Water
Liquid category (EN1717): class 3
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with threaded connections
Port diameter: 1/2inch
DN size: 15mm
Max. media temperature: 65C


CA295-1/2AGB

Honeywell Backflow preventer compact construction with threaded connectors, CA295

Backflow preventers are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 3 to EN 1717 are protected.
Approvals: KIWA-UK, KIWA, WRAS, BELGAQUA, NF, tested to EN 14367
Integral strainer
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate performance
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Media: Water
Liquid category (EN1717): class 3
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard Version acc. EN14367, all materials acc. WRAS
Port diameter: 1/2inch
DN size: 15mm
Max. media temperature: 60C


CA295-3/4A

Honeywell Backflow preventer compact construction with threaded connectors, CA295

Backflow preventers are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 3 to EN 1717 are protected.
Approvals: KIWA-UK, KIWA, WRAS, BELGAQUA, NF, tested to EN 14367
Integral strainer
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate performance
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Media: Water
Liquid category (EN1717): class 3
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard version with threaded connections
Port diameter: 3/4inch
DN size: 20mm
Max. media temperature: 65C


CA295-3/4AGB

Honeywell Backflow preventer compact construction with threaded connectors, CA295

Backflow preventers are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 3 to EN 1717 are protected.
Approvals: KIWA-UK, KIWA, WRAS, BELGAQUA, NF, tested to EN 14367
Integral strainer
Compact construction
Easy access to all internal components
Low pressure loss and high flow rate performance
Triple security - two check valves and a discharge valve separate the backflow preventer into three pressure zones
Meets KTW regulations for potable water
Media: Water
Liquid category (EN1717): class 3
Body material: brass, dezincification resistant
Port connection: external threads
Nominal pressure: PN10
Minimum inlet pressure: 1.5bar
Mounting position: horizontal

Standard Version acc. EN14367, all materials acc. WRAS
Port diameter: 3/4inch
DN size: 20mm
Max. media temperature: 60C


CARE-80-BASIC

Honeywell CARE software

Excel Computer Aided Regulation Engineering ('CARE') software provides graphic tools to create data files and control programs for Excel 50, Excel 80, Excel 100, Excel 500, Excel 600, EXCEL 800, Excel-WEB and Open Point Server Controllers. CARE is additionally capable to replace a LON Engineering Tool for all LonMark compliant devices.
CARE can be used to program any application with the free programmable Controllers from Honeywell.
CARE supports:
For C-Bus System: XL50, Excel 80, Excel 100, XL500 (to be programmed as EXCEL 500), XL500, Excel 600 and XL800 Controllers.
For BACnet System: XLWeb and XLWEB II Controllers

CARE New Licenses (delivered with protection plug)
Product description: CARE 10 Basic Version for XL5000 System engineering (XL50, XL100, XC5010C, XCL8010, XCL5010, EXCEL-WEB) with LON engineering


CARE-80-FULL

Honeywell CARE software

Excel Computer Aided Regulation Engineering ('CARE') software provides graphic tools to create data files and control programs for Excel 50, Excel 80, Excel 100, Excel 500, Excel 600, EXCEL 800, Excel-WEB and Open Point Server Controllers. CARE is additionally capable to replace a LON Engineering Tool for all LonMark compliant devices.
CARE can be used to program any application with the free programmable Controllers from Honeywell.
CARE supports:
For C-Bus System: XL50, Excel 80, Excel 100, XL500 (to be programmed as EXCEL 500), XL500, Excel 600 and XL800 Controllers.
For BACnet System: XLWeb and XLWEB II Controllers

CARE New Licenses (delivered with protection plug)
Product description: CARE 10 All Features including RACL and ASPECD Support


CARE-80-LNS

Honeywell CARE software

Excel Computer Aided Regulation Engineering ('CARE') software provides graphic tools to create data files and control programs for Excel 50, Excel 80, Excel 100, Excel 500, Excel 600, EXCEL 800, Excel-WEB and Open Point Server Controllers. CARE is additionally capable to replace a LON Engineering Tool for all LonMark compliant devices.
CARE can be used to program any application with the free programmable Controllers from Honeywell.
CARE supports:
For C-Bus System: XL50, Excel 80, Excel 100, XL500 (to be programmed as EXCEL 500), XL500, Excel 600 and XL800 Controllers.
For BACnet System: XLWeb and XLWEB II Controllers

CARE New Licenses (delivered with protection plug)
Product description: CARE 10 additionally with LNS Turbo License with one device credit


CBU140-25A-043

Honeywell Compact Booster Unit - single pump, CBU140

Fully automatic, ready-for-connection compact booster unit consisting of a single pump unit and a supply container for hygienic separation of drinking water and liquids of category 5 (agricultural businesses, slaughter houses, biological laboratories, sub-surface sprinkling systems) according to EN 1717.
The system has a mechanical floating valve in the inlet and can be switched on and off as required. The compact construction allows for installation in narrow supply rooms. The system comes ready to plug in and is equipped with a pump control and additionally a pressure gauge. A membrane-based pressure expansion vessel, included in delivery, must be installed in the pressure lines and serves to reduce the frequency of operation. The compact booster unit is a separation of systems as a means to protect drinking water from being contaminated by liquids of category 5 according to EN 1717.
Max. ambient temperature: 40C
Max. media temperature: 35C
Pump: Single
Consists of: Plug-in ready compact booster unit, consisting of:
self-priming multi-stage centrifugal pump
monitoring and control unit for the centrifugal pump
system control
backfeed tank with integrated drinking water backfeed via mechanical floating valve and free outlet according to EN 1717
fastening set for wall mounting, consisting of screws, wall plugs and mounting bracket
flexible expansion joint connection PN10 with DVGW-/TV approval and 10-year guarantee for the pressure side as well as the drinking water connection (length approx. 30/50cm)
Membrane pressure expansion vessel
Installation manual with mounting template
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Power consumption: max. 800W
Volumetric flow: 4m3/h
Pumping height: 43m


CBU144-50A-042

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 42m


CBU144-50A-052

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 52m


CBU144-50A-063

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 63m


CBU144-50A-074

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 74m


CBU144-50A-085

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 85m


CBU144-50A-095

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 95m


CBU144-50A-105

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 105m


CBU144-65A-128

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 18m3/h
Pumping height: 125m


CBU144-80B-052

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 51m


CBU144-80B-063

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 62m


CBU144-80B-073

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 72m


CBU144-80B-084

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 82m


CBU144-80B-094

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 92m


CBU144-80B-104

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 102m


CBU144-80B-114

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 112m


CBU144-80B-125

Honeywell Compact Booster Unit - single pump, CBU144

Honeywell Compact Booster Unit - single pump CBU144 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications acc. to DIN 14462 and DIN1988-600 with free outlet type AB and a vertical high-pressure pump.
Fully automatic, fully wired Compact Booster Unit-single pump with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and cate-gory 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The single pump booster unit has a pump, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - single pump
Volumetric flow: 36m3/h
Pumping height: 122m


CBU145-50A-042

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 42m


CBU145-50A-052

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 52m


CBU145-50A-063

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 63m


CBU145-50A-074

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 74m


CBU145-50A-085

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 85m


CBU145-50A-095

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 95m


CBU145-50A-105

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 105m


CBU145-65A-128

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 18m3/h
Pumping height: 125m


CBU145-80B-052

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 51m


CBU145-80B-063

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 62m


CBU145-80B-073

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 72m


CBU145-80B-084

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 82m


CBU145-80B-094

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 92m


CBU145-80B-104

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 102m


CBU145-80B-114

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 112m


CBU145-80B-125

Honeywell Compact Booster Unit - double pump, CBU145

Honeywell Compact Booster Unit - double pump CBU145 as a safety device to separate potable water from category 5 fluids according to DIN EN 1717 for fire extinguisher applications according to DIN 14462 and DIN1988-600 with free outlet type AB and vertical high-pressure pumps.
Fully automatic, fully wired Compact Booster Unit-double pump with modular design comprising a double pump system with redundant operation and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Double
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
The double pump booster unit has two pumps, a control unit, valves and connected piping. The pressure switch and temperature sensor are installed, wired and preset with standard default values in the factory.
Buffer tank with inlet and flushing apparatus as well as level, overflow and dry running monitor. The components are assembled and preset in the factory. The electrical components are connected to the control unit of the booster station with plug connections. Thus if required an electric separation can be made.
A common base frame for the double pump booster unit and the buffer tank that allows tranportation with a standard pallet hand forklift.The pumps and base frame are equipped with vibration dampers.
Highest protection level for category 5 fluids
Compact Booster Unit - double pump with redundant operation
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Hygienically non-hazardous due to DVGW-certified automatic flushing valve and refilling valve materials acc. KTW & W270
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to DIN 1988-500
Safe operation in case of fire due to construction and function according to DIN 14462: 2011-08

Compact Booster Unit - double pump
Volumetric flow: 36m3/h
Pumping height: 122m


CBU146-32A-060

Honeywell Compact Booster Unit - single pump, CBU146

Speed controlled compact booster unit with a vertical high-pressure pump as a safety device to separate potable water from category 5 fluids according to EN 1717 .
Fully automatic, fully wired Compact Booster Unit with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure, the flow rate is controlled via frequency inverter.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
Speed-controlled compact buster unit with: a normal sucking, vertical high-pressure rotary pump with all components in contact with the medium made of stainless steel; Check valve; Shut-off valve on the inlet and outlet sides; Diaphragm expansion vessel on the outlet side as vessel; Pressure sensor on the pressure side; Vibration damper between pump and base frame; Pressure gauge display; Shut-off valve, lockable; Piping made of stainless steel; The system is connected to the installation pipeline with G1 1/4", G2" or G2 1/2" (depending on version) ; Base frame made of coated steel
Self-cooled frequency converter adapted on the motor
Buffer tank made of polyethylene with: Non-circular, free overflow according to DIN EN 13077, Type AB; Drainage connection DN 150 (nozzles) with integrated siphon trap; Tank volume according to DIN 1988-500 or individual approved; Potable water backfeed via floating valve, suitable for potable water
Switch cabinet consists of: Power supply connection via 3/N/PE, AC 400V, 50Hz; LED, green for normal function, yellow for warning, red for alarm and description text in the Display, Terminal strip/clamps with labels for all connections; Plug connectors to connect easily with the electrical equip-ment fitted to the supply container.
Messages sent via potential-free contact for alarms, warnings and pump run indicator
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Flow rate regulation per frequency inverter
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Pumping height: 60m

Compact Booster Unit - single pump
Volumetric flow: 7m3/h


CBU146-40A-060

Honeywell Compact Booster Unit - single pump, CBU146

Speed controlled compact booster unit with a vertical high-pressure pump as a safety device to separate potable water from category 5 fluids according to EN 1717 .
Fully automatic, fully wired Compact Booster Unit with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure, the flow rate is controlled via frequency inverter.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
Speed-controlled compact buster unit with: a normal sucking, vertical high-pressure rotary pump with all components in contact with the medium made of stainless steel; Check valve; Shut-off valve on the inlet and outlet sides; Diaphragm expansion vessel on the outlet side as vessel; Pressure sensor on the pressure side; Vibration damper between pump and base frame; Pressure gauge display; Shut-off valve, lockable; Piping made of stainless steel; The system is connected to the installation pipeline with G1 1/4", G2" or G2 1/2" (depending on version) ; Base frame made of coated steel
Self-cooled frequency converter adapted on the motor
Buffer tank made of polyethylene with: Non-circular, free overflow according to DIN EN 13077, Type AB; Drainage connection DN 150 (nozzles) with integrated siphon trap; Tank volume according to DIN 1988-500 or individual approved; Potable water backfeed via floating valve, suitable for potable water
Switch cabinet consists of: Power supply connection via 3/N/PE, AC 400V, 50Hz; LED, green for normal function, yellow for warning, red for alarm and description text in the Display, Terminal strip/clamps with labels for all connections; Plug connectors to connect easily with the electrical equip-ment fitted to the supply container.
Messages sent via potential-free contact for alarms, warnings and pump run indicator
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Flow rate regulation per frequency inverter
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Pumping height: 60m

Compact Booster Unit - single pump
Volumetric flow: 11m3/h


CBU146-50A-060

Honeywell Compact Booster Unit - single pump, CBU146

Speed controlled compact booster unit with a vertical high-pressure pump as a safety device to separate potable water from category 5 fluids according to EN 1717 .
Fully automatic, fully wired Compact Booster Unit with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure, the flow rate is controlled via frequency inverter.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
Speed-controlled compact buster unit with: a normal sucking, vertical high-pressure rotary pump with all components in contact with the medium made of stainless steel; Check valve; Shut-off valve on the inlet and outlet sides; Diaphragm expansion vessel on the outlet side as vessel; Pressure sensor on the pressure side; Vibration damper between pump and base frame; Pressure gauge display; Shut-off valve, lockable; Piping made of stainless steel; The system is connected to the installation pipeline with G1 1/4", G2" or G2 1/2" (depending on version) ; Base frame made of coated steel
Self-cooled frequency converter adapted on the motor
Buffer tank made of polyethylene with: Non-circular, free overflow according to DIN EN 13077, Type AB; Drainage connection DN 150 (nozzles) with integrated siphon trap; Tank volume according to DIN 1988-500 or individual approved; Potable water backfeed via floating valve, suitable for potable water
Switch cabinet consists of: Power supply connection via 3/N/PE, AC 400V, 50Hz; LED, green for normal function, yellow for warning, red for alarm and description text in the Display, Terminal strip/clamps with labels for all connections; Plug connectors to connect easily with the electrical equip-ment fitted to the supply container.
Messages sent via potential-free contact for alarms, warnings and pump run indicator
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Flow rate regulation per frequency inverter
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Pumping height: 60m

Compact Booster Unit - single pump
Volumetric flow: 19m3/h


CBU146-65A-060

Honeywell Compact Booster Unit - single pump, CBU146

Speed controlled compact booster unit with a vertical high-pressure pump as a safety device to separate potable water from category 5 fluids according to EN 1717 .
Fully automatic, fully wired Compact Booster Unit with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure, the flow rate is controlled via frequency inverter.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
Speed-controlled compact buster unit with: a normal sucking, vertical high-pressure rotary pump with all components in contact with the medium made of stainless steel; Check valve; Shut-off valve on the inlet and outlet sides; Diaphragm expansion vessel on the outlet side as vessel; Pressure sensor on the pressure side; Vibration damper between pump and base frame; Pressure gauge display; Shut-off valve, lockable; Piping made of stainless steel; The system is connected to the installation pipeline with G1 1/4", G2" or G2 1/2" (depending on version) ; Base frame made of coated steel
Self-cooled frequency converter adapted on the motor
Buffer tank made of polyethylene with: Non-circular, free overflow according to DIN EN 13077, Type AB; Drainage connection DN 150 (nozzles) with integrated siphon trap; Tank volume according to DIN 1988-500 or individual approved; Potable water backfeed via floating valve, suitable for potable water
Switch cabinet consists of: Power supply connection via 3/N/PE, AC 400V, 50Hz; LED, green for normal function, yellow for warning, red for alarm and description text in the Display, Terminal strip/clamps with labels for all connections; Plug connectors to connect easily with the electrical equip-ment fitted to the supply container.
Messages sent via potential-free contact for alarms, warnings and pump run indicator
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Flow rate regulation per frequency inverter
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Pumping height: 60m

Compact Booster Unit - single pump
Volumetric flow: 24m3/h


CBU146-65B-060

Honeywell Compact Booster Unit - single pump, CBU146

Speed controlled compact booster unit with a vertical high-pressure pump as a safety device to separate potable water from category 5 fluids according to EN 1717 .
Fully automatic, fully wired Compact Booster Unit with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure, the flow rate is controlled via frequency inverter.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
Speed-controlled compact buster unit with: a normal sucking, vertical high-pressure rotary pump with all components in contact with the medium made of stainless steel; Check valve; Shut-off valve on the inlet and outlet sides; Diaphragm expansion vessel on the outlet side as vessel; Pressure sensor on the pressure side; Vibration damper between pump and base frame; Pressure gauge display; Shut-off valve, lockable; Piping made of stainless steel; The system is connected to the installation pipeline with G1 1/4", G2" or G2 1/2" (depending on version) ; Base frame made of coated steel
Self-cooled frequency converter adapted on the motor
Buffer tank made of polyethylene with: Non-circular, free overflow according to DIN EN 13077, Type AB; Drainage connection DN 150 (nozzles) with integrated siphon trap; Tank volume according to DIN 1988-500 or individual approved; Potable water backfeed via floating valve, suitable for potable water
Switch cabinet consists of: Power supply connection via 3/N/PE, AC 400V, 50Hz; LED, green for normal function, yellow for warning, red for alarm and description text in the Display, Terminal strip/clamps with labels for all connections; Plug connectors to connect easily with the electrical equip-ment fitted to the supply container.
Messages sent via potential-free contact for alarms, warnings and pump run indicator
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Flow rate regulation per frequency inverter
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Pumping height: 60m

Compact Booster Unit - single pump
Volumetric flow: 36m3/h


CBU146-80B-060

Honeywell Compact Booster Unit - single pump, CBU146

Speed controlled compact booster unit with a vertical high-pressure pump as a safety device to separate potable water from category 5 fluids according to EN 1717 .
Fully automatic, fully wired Compact Booster Unit with modular design comprising a single pump system and a buffer tank for the hygienic separation of potable water and category 5 fluids according to DIN EN 1717, on a common base frame. The modular design makes it possible to disconnect modules for installation in buildings with limited space. The system is switched on and off regulated by pressure, the flow rate is controlled via frequency inverter.
Max. ambient temperature: 40C
Max. media temperature: 30C
Pump: Single
Consists of: The Compact Booster Unit consists of the following modules, that can be disassembled (for example for transport purposes)
Speed-controlled compact buster unit with: a normal sucking, vertical high-pressure rotary pump with all components in contact with the medium made of stainless steel; Check valve; Shut-off valve on the inlet and outlet sides; Diaphragm expansion vessel on the outlet side as vessel; Pressure sensor on the pressure side; Vibration damper between pump and base frame; Pressure gauge display; Shut-off valve, lockable; Piping made of stainless steel; The system is connected to the installation pipeline with G1 1/4", G2" or G2 1/2" (depending on version) ; Base frame made of coated steel
Self-cooled frequency converter adapted on the motor
Buffer tank made of polyethylene with: Non-circular, free overflow according to DIN EN 13077, Type AB; Drainage connection DN 150 (nozzles) with integrated siphon trap; Tank volume according to DIN 1988-500 or individual approved; Potable water backfeed via floating valve, suitable for potable water
Switch cabinet consists of: Power supply connection via 3/N/PE, AC 400V, 50Hz; LED, green for normal function, yellow for warning, red for alarm and description text in the Display, Terminal strip/clamps with labels for all connections; Plug connectors to connect easily with the electrical equip-ment fitted to the supply container.
Messages sent via potential-free contact for alarms, warnings and pump run indicator
Pre-assembled, ready for installation
No risk of microbial contamination due to hygienic separation of potable water from non-potable water
Flow rate regulation per frequency inverter
Easy installation due to modular construction and draining with integrated siphon trap
Reliable operation due to buffer tank with usable volume according to EN 806-2
Pumping height: 60m

Compact Booster Unit - single pump
Volumetric flow: 43m3/h


CE10S-A

Honeywell Softening device KaltecSoft, KS10S
Spare parts

Control panel for KS10S



CK70HN-3/4A

Honeywell PrimusCenter DWC7000
Accessories

Connection set for refilling combination for direct connection of refilling combinations



CK70WS-3/4A

Honeywell PrimusCenter DWC7000
Accessories

Connection set for softening unit. Installation components for additional connection of softening units



CLMERL2

Honeywell Controllers with ROHS II Certificate


BACNET MS/TP HVAC CONTR.



CLMERL8

Honeywell Controllers with ROHS II Certificate


BACNET MS/TP HVAC CONTR.



CLMERS4

Honeywell Controllers with ROHS II Certificate


BACNET MS/TP HVAC CONTR.



CLSE1L230

Honeywell Controllers with ROHS II Certificate


CL FCU 230 VAC



CLSE1L24

Honeywell Controllers with ROHS II Certificate


CL FCU 24 VAC



CLSE2L230

Honeywell Controllers with ROHS II Certificate


CL FCU CTR. VAR. FANSPEED



CLSE2L24

Honeywell Controllers with ROHS II Certificate


CL FCU CTR. VAR. FANSPEED



CLSE3L230

Honeywell Controllers with ROHS II Certificate


SERVAL RM CONTR.



CM31I

Honeywell 1-day analogue Chronotherm with unique wave design CM31

Analogue programmable thermostat with 1 day program.
For general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 1 year typical
Switch function/capacity: SPDT, 24..230V, 50..60Hz, 0,5..8A resistive, 0,5..3A inductive (0.6 pf)
Approvals: CE
Protection class: IP30
Terminal max. wire size: 2.5mm2
ErP Class: IV
Temperature setpoint range comfort: 10...30C
Temperature setpoint range economy: 5...25C
Temperature control accuracy: 0.5C
Control functions: proportional + integral (PI) temperature control
Time setting resolution: 15 minutes, minimum setpoint change interval 15 minutes
Heating /Cooling application: Heating only
Manual operation functions: override switch with: comfort, economy and auto positions
Housing (HxWxD): 90mm|135mm|29mm


Product literature language: Italian
Model: for Italy only


CM37I

Honeywell 7-day analogue Chronotherm with unique wave design CM37

Analogue programmable thermostat with 7 day program.
For general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 1 year typical
Switch function/capacity: SPDT, 24..230V, 50..60Hz, 0,5..8A resistive, 0,5..3A inductive (0.6 pf)
Approvals: CE
Protection class: IP30
Terminal max. wire size: 2.5mm2
ErP Class: IV
Temperature setpoint range comfort: 10...30C
Temperature setpoint range economy: 5...25C
Temperature control accuracy: 0.5C
Control functions: proportional + integral (PI) temperature control
Time setting resolution: 1 hour, minimum setpoint change interval 2 hours
Heating /Cooling application: Heating only
Manual operation functions: override switch with: comfort, economy and auto positions
Housing (HxWxD): 90mm|135mm|29mm


Product literature language: Italian
Model: for Italy only


CM67RFMV

Honeywell Universal controller for mixing circuit
Additional products for HM80

Chronotherm room thermostat



CM901I

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Party timer: no
Day off function: no
TRV-mode: no
Product literature language: I
Display: Italian


CM907I

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: I
Display: Italian


CMS921B1018

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (Belgian version)



CMS921B1026

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (French version)



CMS921B1042

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (UK version)



CMS927B1015

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (Belgian version)



CMS927B1023

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (French version)



CMS927B1031

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (Spanish version)



CMS927B1049

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (UK/English version)



CMS927B1056

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (Italian version)



CMS927B1064

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (German/Hungarian version)



CMS927B1072

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921
CM920 Room unit; ErP Class V

7-day Room unit spare (Cz, Sk, Pol version)



CMT507A1007

Honeywell Chronotherm with subtle, unobtrusive styling and compact design CM507

The CM507 is a modern 7-day programmable room thermostat with a large LCD and clear temperature display.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPST, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...28C
Temperature control accuracy: 0.5C
Control functions: adaptive dead band
Time setting resolution: time of day - 1 minute, program - 1 hour steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN)
Housing (HxWxD): 75mm|127mm|27mm
user program stored in non-volatile memory
installers set-up mode
time-line bar graph
ErP Class: I
Default time display format: AM/PM
User panel language: English
Product literature language: I, PO, E, F, RO, SK, CZ, PL, EN, HU


CMT701A1006

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Holiday mode: no
Temperature setpoints per day: 4
Product literature language: I, PO, E, F, D, NL


CMT701A1014

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

1-day program
Default time display format: AM/PM
Holiday mode: no
Temperature setpoints per day: 4
Product literature language: UK


CMT702A1004

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

1+1-day program
Default time display format: 24 h
Holiday mode: no
Temperature setpoints per day: 4
Product literature language: I, PO, E, F, D, NL


CMT702A1012

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

1+1-day program
Default time display format: 24 h
Holiday mode: no
Temperature setpoints per day: 6
Product literature language: I, PO, E, F, D, NL


CMT707A1003

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Holiday mode: yes
Temperature setpoints per day: 4
Product literature language: I, PO, E, F, D, NL


CMT707A1011

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Holiday mode: yes
Temperature setpoints per day: 4
Product literature language: CZ, PL, SK, HU, RO, RU


CMT707A1029

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

7-day program
Default time display format: AM/PM
Holiday mode: yes
Temperature setpoints per day: 4
Product literature language: UK


CMT707A1037

Honeywell Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: Heating only
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 88.5mm|133mm|26mm
user program stored in non-volatile memory
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Holiday mode: yes
Temperature setpoints per day: 6
Product literature language: UK, GR, TU, CR, SL


CMT901A1010

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Party timer: no
Day off function: no
TRV-mode: no
Product literature language: NL, F
Display: Dutch/French


CMT901A1028

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Party timer: no
Day off function: no
TRV-mode: no
Product literature language: F
Display: French


CMT901A1036

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Party timer: no
Day off function: no
TRV-mode: no
Product literature language: E
Display: Spanish


CMT901A1044

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

1-day program
Default time display format: AM/PM
Party timer: no
Day off function: no
TRV-mode: no
Product literature language: UK
Display: English


CMT907A1017

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: NL, F
Display: Dutch/French


CMT907A1025

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: F
Display: French


CMT907A1033

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: E
Display: Spanish


CMT907A1041

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: AM/PM
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: UK
Display: English


CMT907A1066

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: HU, D, PO
Display: German/Hungarian/Portugese


CMT907A1074

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
TRV-mode: no
Product literature language: CZ, SK, PL
Display: Czech/Slovak/Polish


CMT907A1082

Honeywell Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.
Power source: battery powered, 2 x 1,5 V AA Alkaline cells supplied
Battery life: 2 years typical for applications with loads smaller than 3 A
Switch function/capacity: SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 5...35C
Temperature control accuracy: 0.5C
Control functions: Proportional + Integral (PI) temperature control
Temperature setpoints per day: 6 independent temperature setpoints
Time setting resolution: time of day - 1 minute, program - 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Housing (HxWxD): 89mm|133mm|26mm
Holiday mode: yes
Optimisation: yes
LCD backlight
automatic summer/winter time change
user program stored in non-volatile memory
input for remote temperature sensor or outside temperature sensor
input for telephone interface connection
installers set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: no
TRV-mode: yes
Product literature language: NL, F
Display: Dutch/French


CMT921A1018

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Party timer: no
Day off function: no
Product literature language: NL, F
Display: Dutch/French


CMT921A1026

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

1-day program
Default time display format: 24 h
Party timer: no
Day off function: no
Product literature language: F
Display: French


CMT921A1042

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

1-day program
Default time display format: AM/PM
Party timer: no
Day off function: no
Product literature language: UK
Display: English


CMT927A1015

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
Product literature language: NL, F
Display: Dutch/French


CMT927A1023

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
Product literature language: F
Display: French


CMT927A1031

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
Product literature language: E
Display: Spanish


CMT927A1049

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: AM/PM
Party timer: yes
Day off function: yes
Product literature language: UK
Display: English


CMT927A1056

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
Product literature language: I
Display: Italian


CMT927A1064

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
Product literature language: D, HU, PO
Display: German/Hungarian/Portugese


CMT927A1072

Honeywell RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.
Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.
Power source: transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz
Battery life: 2 years typical
Switch function/capacity: SPDT, 24..230 Vac, 10 A resistive, 3 A inductive
Protection class: IP30 (receiver and transmitter)
RF frequency range: 868...868.6MHz
Blocking immunity: Receiver class 2 (ETSI EN300220-1 version 1.3.1)
Terminal max. wire size: 2.5mm2
Temp. setpoint range: 0...35C
Control functions: Fuzzy Logic Algorithm
Temperature setpoints per day: 6
Time setting resolution: time of day 1 minute, program 10 minute steps
Heating /Cooling application: H or C
Manual operation functions: manual setpoint setting (MAN) and frost protection (OFF) modes available
Holiday mode: yes
Optimisation: yes
LCD backlighting
automatic summer/winter time change
user program stored in non-volatile memory
factory pre-set RF link between the room unit and the relay box
installer set-up mode
ErP Class: IV

7-day program
Default time display format: 24 h
Party timer: yes
Day off function: yes
Product literature language: CZ, SK, PL
Display: Czech/Slovak/Polish


CO020012

Honeywell Solenoid gas valve, normally closed VE400AA
Electrical connection

DIN Plug



COMP-IP21-KIT1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive COMPACT IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive Compact size MI1
NXL HVAC: no
NXS: no
SmartDrive HVAC: yes
SmartDrive Compact: no


COMP-IP21-KIT2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive COMPACT IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive Compact size MI2
NXL HVAC: no
NXS: no
SmartDrive HVAC: yes
SmartDrive Compact: no


COMP-IP21-KIT3

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive COMPACT IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive Compact size MI3
NXL HVAC: no
NXS: no
SmartDrive HVAC: yes
SmartDrive Compact: no


COMP-LOADER

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive PC connection tools and cables
Product description: SmartDrive Compact Parameter download/upload and PC interface tool with cable for USB connection to PC
NXL HVAC: no
NXS: no
SmartDrive HVAC: no
SmartDrive Compact: yes


COMP-LOADER-NC

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive PC connection tools and cables
Product description: SmartDrive Compact Parameter download/upload and PC interface tool without cable
NXL HVAC: no
NXS: no
SmartDrive HVAC: no
SmartDrive Compact: yes


COMP-NEMA1-KIT1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive COMPACT IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive Compact size MI1
NXL HVAC: no
NXS: no
SmartDrive HVAC: yes
SmartDrive Compact: no


COMP-NEMA1-KIT2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive COMPACT IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive Compact size MI2
NXL HVAC: no
NXS: no
SmartDrive HVAC: yes
SmartDrive Compact: no


COMP-NEMA1-KIT3

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive COMPACT IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive Compact size MI3
NXL HVAC: no
NXS: no
SmartDrive HVAC: yes
SmartDrive Compact: no


COMP230-1P1-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 4.8A
High overload (for Machines): 1.1kW
High overload Icont: 4.8A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-1P5-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 7A
High overload (for Machines): 1.5kW
High overload Icont: 7A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-2P2-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 9.6A
High overload (for Machines): 2.2kW
High overload Icont: 9.6A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-P37-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 0.37kW
Low overload Icont: 2.4A
High overload (for Machines): 0.37kW
High overload Icont: 2.4A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-P75-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 0.75kW
Low overload Icont: 3.7A
High overload (for Machines): 0.75kW
High overload Icont: 3.7A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP400-1P1-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.3A
High overload (for Machines): 1.1kW
High overload Icont: 3.3A
Brake chopper: no
1 phase input: no
3 phases input: yes


COMP400-1P5-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4.3A
High overload (for Machines): 1.5kW
High overload Icont: 4.3A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-2P2-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.6A
High overload (for Machines): 2.2kW
High overload Icont: 5.6A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-3P0-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 3kW
Low overload Icont: 7.6A
High overload (for Machines): 3kW
High overload Icont: 7.6A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-4P0-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9A
High overload (for Machines): 4kW
High overload Icont: 9A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-5P5-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
High overload (for Machines): 5.5kW
High overload Icont: 12A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-P55-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 0.55kW
Low overload Icont: 1.9A
High overload (for Machines): 0.55kW
High overload Icont: 1.9A
Brake chopper: no
1 phase input: no
3 phases input: yes


COMP400-P75-20

Honeywell Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 0.75kW
Low overload Icont: 2.4A
High overload (for Machines): 0.75kW
High overload Icont: 2.4A
Brake chopper: no
1 phase input: no
3 phases input: yes


CP10S-A

Honeywell Softening device KaltecSoft, KS10S
Spare parts

Stainless steel corrugated pipe for KS10S



CPO-CORE

Honeywell Controllers with ROHS II Certificate


BACNET ROUTER



CPO-DIO

Honeywell Controllers with ROHS II Certificate


CPO EXIO EXP BRD/MSTP CONTR. 8UI 8DI 16DO



CPO-EXPIO

Honeywell Controllers with ROHS II Certificate


CPO EXIO EXP BRD 8UI 6DI 6AO 4DO



CPO-FTCL

Honeywell Controllers with ROHS II Certificate


CPO FCU TERM. COVER BULK PCK.



CPO-IO830A

Honeywell Controllers with ROHS II Certificate


Mixed I/O Module



CPO-IPC

Honeywell Controllers with ROHS II Certificate


CPO IPC PLANT CONTR. 8UI 6DI 6AO 4DO



CPO-PC-6A

Honeywell Controllers with ROHS II Certificate


CPO Plant Controller



CPO-RL1

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 2
UI: 6
Relay outputs: 1
Triac: 2
Control software: config/free progr.


CPO-RL2

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 2
UI: 6
Relay outputs: 4
Triac: 4
Control software: config/free progr.


CPO-RL3

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 2
UI: 6
Relay outputs: 4
Triac: 4
Control software: config/free progr.


CPO-RL4

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h


CPO-RL5

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h; removable terminals


CPO-RL6

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h


CPO-RL7U

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h; watchdog relay; ambient temp. -40..65C


CPO-RL8

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: with lighting support


CPO-RS1

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 3
UI: 3
Relay outputs: 0
Triac: 0
Control software: config/free progr.


CPO-RS2

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 1
UI: 3
Relay outputs: 0
Triac: 0
Control software: conf. only


CPO-RS3

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 0
UI: 3
Relay outputs: 3
Triac: 2
Control software: conf. only


CPO-RS4

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 4
UI: 4
Relay outputs: 4
Triac: 2
Control software: config/free progr.


CPO-RS5

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 4
UI: 4
Relay outputs: 4
Triac: 2
Control software: config/free progr.


CPO-RS6

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 1
UI: 3
Relay outputs: 0
Triac: 2
Control software: conf. only


CPO-SPC

Honeywell Controllers with ROHS II Certificate


CPO SM POINT CONTR. 6UI 4DI 3AO 8DO



CPO-VAV

Honeywell Controllers with ROHS II Certificate


CPO VAV CONTR. 6UI 4DI 3AO 8DO



CPO-VAV2A

Honeywell Controllers with ROHS II Certificate


CPO VAV CONTR. INTEGRAL ACT.



CRT12

Honeywell Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 288 VA


CRT2

Honeywell Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 48 VA


CRT6

Honeywell Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 144 VA


CRT6-12

Honeywell Transformer, 2 secondary windings

Protection class: IP00
Input voltage: 230 V, 50Hz
Output voltage: 2 x 24Vac, separated
With mains fuse. VDE0551 mark.


Model: 150/250 VA


CRT6-6

Honeywell Transformer, 2 secondary windings

Protection class: IP00
Input voltage: 230 V, 50Hz
Output voltage: 2 x 24Vac, separated
With mains fuse. VDE0551 mark.


Model: 144/144 VA


CS92A1007

Honeywell Wireless Heating and Hot Water Control Systems, Sundial RF2
Spare units

Wireless DHW thermostat



CVC-Y29110

Honeywell Series CVC, HLE - Hot gas bypass valves with fixed orifice, internal pressure equalisation and adjustable suction pressure limitation

Series CVC, HLE Hot gas bypass valves with fixed orifice, internal pressure equalisation and adjustable suction pressure limitation.
Hot gas bypass valves series CVC and HLE are used to adjust the compressor capacity to the actual evaporator capacity in a refrigerating plant. The hot gas bypass valve can be installed in a bypass tube between the hot gas line and suction line. The suction pressure is downward limited by flowing hot gas from the high pressure to the low pressure side. For plants in general refrigeration and for original equipment such as dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable suction pressure limitation
Extreme durability thanks to welded stainless steel head and stainless steel diaphragm
Special versions (bypass, other refrigerants, etc.) on request
For capacities of orifices download attached engineering manual or check with our selection software Valve Tool
Series: CVC
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, power head
Copper parts: connection tube
Max. ambient temperature: 100C
Max. pressure PS: 25.5bar
Max. test pressure: 28bar
Thermal charge: all CFC, HCFC, HFC, not for ammonia
Download PDF with Series number in Table

CVC
Orifice size: 4
Adjusting range: 1...6bar
Factory setting: 3.2bar
Inlet ODF: 6mm
Outlet ODF: 12mm


CVC-Y29210

Honeywell Series CVC, HLE - Hot gas bypass valves with fixed orifice, internal pressure equalisation and adjustable suction pressure limitation

Series CVC, HLE Hot gas bypass valves with fixed orifice, internal pressure equalisation and adjustable suction pressure limitation.
Hot gas bypass valves series CVC and HLE are used to adjust the compressor capacity to the actual evaporator capacity in a refrigerating plant. The hot gas bypass valve can be installed in a bypass tube between the hot gas line and suction line. The suction pressure is downward limited by flowing hot gas from the high pressure to the low pressure side. For plants in general refrigeration and for original equipment such as dehumidifiers, air driers, water coolers or ice-making machines.
Smallest dimensions
High performance
Hermetic construction
Adjustable suction pressure limitation
Extreme durability thanks to welded stainless steel head and stainless steel diaphragm
Special versions (bypass, other refrigerants, etc.) on request
For capacities of orifices download attached engineering manual or check with our selection software Valve Tool
Series: CVC
Orifice: solid built-in
Connections: solder
Pressure equalizer: internal
Balanced port: no
Brass parts: body
Stainless steel parts: internals, power head
Copper parts: connection tube
Max. ambient temperature: 100C
Max. pressure PS: 25.5bar
Max. test pressure: 28bar
Thermal charge: all CFC, HCFC, HFC, not for ammonia
Download PDF with Series number in Table

CVC
Orifice size: 4
Adjusting range: 1...6bar
Factory setting: 3.2bar
Inlet ODF: 1/4"
Outlet ODF: 1/2"


CX-FR

Honeywell Flow rate regulator, VR300
Spare Parts

Replacement pilot valve for all sizes



CX-PR

Honeywell Pressure regulator, DR300
Spare Parts

Replacement pilot valve for sizes DN 50 - DN 450



CX-PS

Honeywell Pressure sustaining valve, DH300
Spare Parts

Replacement pilot valve for all sizes



D03-1/2C

Honeywell Standard pattern pressure reducing valve, D03

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Outlet pressure adjustable with adjusting screw
The adjustment spring is not in contact with the drinking water
Compact construction
Medium type: drinking water
Max. operating temp.: 40C
Body material: brass
Spring bonnet material: brass
Body finishing: nickel plated
Flow capacity Kvs: 1.73
Outlet pressure: 1.5...6bar
Balanced seat design: yes
Max. inlet pressure: 10bar
Min. pressure drop: 1bar

Internal threads on both sides
Connection Inlet/Outlet: internal thread
Port diameter: 1/2inch
DN size: 15mm


D03-3/4C

Honeywell Standard pattern pressure reducing valve, D03

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Outlet pressure adjustable with adjusting screw
The adjustment spring is not in contact with the drinking water
Compact construction
Medium type: drinking water
Max. operating temp.: 40C
Body material: brass
Spring bonnet material: brass
Body finishing: nickel plated
Flow capacity Kvs: 1.73
Outlet pressure: 1.5...6bar
Balanced seat design: yes
Max. inlet pressure: 10bar
Min. pressure drop: 1bar

Internal threads on both sides
Connection Inlet/Outlet: internal thread
Port diameter: 3/4inch
DN size: 20mm


D03-3/4ZA

Honeywell Standard pattern pressure reducing valve, D03

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Outlet pressure adjustable with adjusting screw
The adjustment spring is not in contact with the drinking water
Compact construction
Medium type: drinking water
Max. operating temp.: 40C
Body material: brass
Spring bonnet material: brass
Body finishing: nickel plated
Flow capacity Kvs: 1.73
Outlet pressure: 1.5...6bar
Balanced seat design: yes
Max. inlet pressure: 10bar
Min. pressure drop: 1bar

Inlet with external thread, outlet with threaded male connection
Connection Inlet/Outlet: IN:ext.thread; OUT:conn.set,ext.thread
Port diameter: 3/4inch
DN size: 20mm


D04FM-1/2A

Honeywell Standard pattern pressure reducing valve with balanced seat, D04FM

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
Outlet pressure adjustable with adjustment knob
The adjustment spring is not in contact with the drinking water
With internal and external threads 3/8" - 3/4"
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Min. pressure drop: 1bar

Standard pattern
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4


D04FM-3/4A

Honeywell Standard pattern pressure reducing valve with balanced seat, D04FM

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
Outlet pressure adjustable with adjustment knob
The adjustment spring is not in contact with the drinking water
With internal and external threads 3/8" - 3/4"
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Min. pressure drop: 1bar

Standard pattern
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 2.6


D04FM-3/8A

Honeywell Standard pattern pressure reducing valve with balanced seat, D04FM

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
Outlet pressure adjustable with adjustment knob
The adjustment spring is not in contact with the drinking water
With internal and external threads 3/8" - 3/4"
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Min. pressure drop: 1bar

Standard pattern
Port diameter: 3/8inch
DN size: 10mm
Flow capacity Kvs: 1.8


D04FMA-1/2

Honeywell Refilling combination, NK300S
Spare Parts

Valve insert complete for size 1/2"



D05F-1/2A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2" and 3/4" with external threads 1"
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.6


D05F-1/2E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2" and 3/4" with external threads 1"
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.6


D05F-1/2EF

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05F-EF

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: NF EN 1567 approved
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...5.5bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.6


D05F-1A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2" and 3/4" with external threads 1"
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3


D05F-1E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2" and 3/4" with external threads 1"
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3


D05F-3/4A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2" and 3/4" with external threads 1"
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 2.8


D05F-3/4E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2" and 3/4" with external threads 1"
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 2.8


D05F-3/4EF

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05F-EF

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: NF EN 1567 approved
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...5.5bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 2.8


D05FA-1/2B

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale , D05F
Spare Parts

Valve insert complete (without filter) for sizes 1/2" - 1"



D05FA-1/2T

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT
Spare Parts

Valve insert complete for sizes 1/2"- 1"



D05FA-11/4B

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS
Spare Parts

Valve insert complete (without filter) for sizes 1 1/4"- 2"



D05FA-11/4T

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT
Spare Parts

Valve insert complete for sizes 1 1/4"- 2"



D05FAM-1/2B

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05F-EF
Spare Parts

Valve insert complete (without filter) for sizes 1/2"- 3/4"



D05FS-1/2A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 3


D05FS-1/2E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 3


D05FS-1/2EF

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS-EF

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: NF EN 1567 approved (1/2" and 3/4")
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 30C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...5.5bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 3


D05FS-11/2A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 7.5


D05FS-11/2E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 7.5


D05FS-11/4A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 7.3


D05FS-11/4E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 7.3


D05FS-1A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3.7


D05FS-1E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3.7


D05FS-1EF

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS-EF

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: NF EN 1567 approved (1/2" and 3/4")
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 30C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...5.5bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3.7


D05FS-2A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 7.7


D05FS-2E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 7.7


D05FS-3/4A

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.5


D05FS-3/4E

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 40C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Outlet pressure: 1.5...6bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.5


D05FS-3/4EF

Honeywell Standard pattern pressure reducing valve with balanced seat and setting scale, D05FS-EF

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: NF EN 1567 approved (1/2" and 3/4")
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1", with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 30C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: external thread
Outlet pressure: 1.5...5.5bar
Max. inlet pressure: 25bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.5


D05FT-1/2A

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 3


D05FT-1/2E

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 3


D05FT-11/2A

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 7.5


D05FT-11/2E

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 7.5


D05FT-11/4A

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 7.3


D05FT-11/4E

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 7.3


D05FT-1A

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3.7


D05FT-1E

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 3.7


D05FT-2A

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 7.7


D05FT-2E

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 7.7


D05FT-3/4A

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern with threaded male connections
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.5


D05FT-3/4E

Honeywell Hot water pattern pressure reducing valve with balanced seat and setting scale, D05FT

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS in progress
Suitable for hot water systems
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
The valve insert is made of dezincification resistant brass and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
With internal and external threads 1/2"- 1"; with external threads 1 1/4"- 2"
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 80C (95C short term)
Body material: brass, dezincification resistant
Spring bonnet material: brass
Outlet pressure: 1.5...6bar
Max. inlet pressure: 16bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Standard pattern without fittings
Connection Inlet/Outlet: external thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.5


D06F-1/2A

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-1/2B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, brass filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4
Max. inlet pressure: 25bar
Filter bowl: brass
Max. operating temp.: 70C


D06F-1/2E

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-1/2LFA

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
All materials are UBA conform
Medium type: drinking water
Body material: leadfree brass
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Nominal pressure: PN16
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Filter bowl: clear
Max. operating temp.: 40C

With leadfree brass threaded male connections, clear filter bowl
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4


D06F-11/2A

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-11/2B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, brass filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6
Max. inlet pressure: 25bar
Filter bowl: brass
Max. operating temp.: 70C


D06F-11/2E

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-11/2LFA

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
All materials are UBA conform
Medium type: drinking water
Body material: leadfree brass
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Nominal pressure: PN16
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Filter bowl: clear
Max. operating temp.: 40C

With leadfree brass threaded male connections, clear filter bowl
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6


D06F-11/4A

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-11/4B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, brass filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9
Max. inlet pressure: 25bar
Filter bowl: brass
Max. operating temp.: 70C


D06F-11/4E

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-11/4LFA

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
All materials are UBA conform
Medium type: drinking water
Body material: leadfree brass
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Nominal pressure: PN16
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Filter bowl: clear
Max. operating temp.: 40C

With leadfree brass threaded male connections, clear filter bowl
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9


D06F-1A

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-1B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, brass filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8
Max. inlet pressure: 25bar
Filter bowl: brass
Max. operating temp.: 70C


D06F-1E

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-1LFA

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
All materials are UBA conform
Medium type: drinking water
Body material: leadfree brass
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Nominal pressure: PN16
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Filter bowl: clear
Max. operating temp.: 40C

With leadfree brass threaded male connections, clear filter bowl
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8


D06F-2A

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-2B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, brass filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12
Max. inlet pressure: 25bar
Filter bowl: brass
Max. operating temp.: 70C


D06F-2E

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-2LFA

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
All materials are UBA conform
Medium type: drinking water
Body material: leadfree brass
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Nominal pressure: PN16
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Filter bowl: clear
Max. operating temp.: 40C

With leadfree brass threaded male connections, clear filter bowl
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12


D06F-3/4A

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.1
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-3/4B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

With threaded male connections, brass filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.1
Max. inlet pressure: 25bar
Filter bowl: brass
Max. operating temp.: 70C


D06F-3/4E

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.1
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06F-3/4LFA

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
SINTEF
VA (ETA)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
All materials are UBA conform
Medium type: drinking water
Body material: leadfree brass
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Nominal pressure: PN16
Filter mesh: 0.16mm
Setpoint scale: yes
Balanced seat design: yes
Outlet pressure: 1.5...6bar
Filter bowl: clear
Max. operating temp.: 40C

With leadfree brass threaded male connections, clear filter bowl
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.1


D06FA-1/2

Honeywell Filling valve, VF06
Spare parts

Valve insert complete /without filter) for sizes 1/2" + 3/4"



D06FA-11/2

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Valve insert complete (without filter) for sizes 1 1/2"+ 2"



D06FA-1A

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH
Spare Parts

Valve insert complete (without filter) for sizes 1"+ 1 1/4"



D06FA-1B

Honeywell Pressure reducing valve with balanced seat and set point scale, D06F
Spare Parts

Valve insert complete (without filter) for sizes 1"+ 1 1/4"



D06FA-A

Honeywell Retrofit reverse rinsing fine filter with clear filter bowl, FN76CS
Accessories

Retrofit pressure reducing valve to upgrade to a filter combination



D06FH-1/2B

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 60C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Filter mesh: 0.16mm
Outlet pressure: 1.5...12bar
Max. inlet pressure: 25bar
Preset outlet pressure: 5bar
Min. pressure drop: 1bar
Balanced seat design: yes
Filter bowl: brass

With threaded male connections, brass filter bowl
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4


D06FH-11/2B

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 60C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Filter mesh: 0.16mm
Outlet pressure: 1.5...12bar
Max. inlet pressure: 25bar
Preset outlet pressure: 5bar
Min. pressure drop: 1bar
Balanced seat design: yes
Filter bowl: brass

With threaded male connections, brass filter bowl
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6


D06FH-11/4B

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 60C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Filter mesh: 0.16mm
Outlet pressure: 1.5...12bar
Max. inlet pressure: 25bar
Preset outlet pressure: 5bar
Min. pressure drop: 1bar
Balanced seat design: yes
Filter bowl: brass

With threaded male connections, brass filter bowl
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 9.1


D06FH-1B

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 60C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Filter mesh: 0.16mm
Outlet pressure: 1.5...12bar
Max. inlet pressure: 25bar
Preset outlet pressure: 5bar
Min. pressure drop: 1bar
Balanced seat design: yes
Filter bowl: brass

With threaded male connections, brass filter bowl
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 7.6


D06FH-2B

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 60C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Filter mesh: 0.16mm
Outlet pressure: 1.5...12bar
Max. inlet pressure: 25bar
Preset outlet pressure: 5bar
Min. pressure drop: 1bar
Balanced seat design: yes
Filter bowl: brass

With threaded male connections, brass filter bowl
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12


D06FH-3/4B

Honeywell High pressure reducing valve with balanced seat and set point scale, D06FH

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Easily retrofittable to convert valve to a reverse-rinsing filter combination
Can be retrofitted with an inlet check valve
Also available without fittings
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Max. operating temp.: 60C (70C with max. press. 10bar)
Body material: brass, dezincification resistant
Spring bonnet material: synthetic material
Connection Inlet/Outlet: conn. set, ext. thread
Filter mesh: 0.16mm
Outlet pressure: 1.5...12bar
Max. inlet pressure: 25bar
Preset outlet pressure: 5bar
Min. pressure drop: 1bar
Balanced seat design: yes
Filter bowl: brass

With threaded male connections, brass filter bowl
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.1


D06FI-1

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA
Spare Parts

Valve insert complete (without filter) for sizes 1"+ 1 1/4"



D06FI-1/2

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA
Spare Parts

Valve insert complete (without filter) for sizes 1/2"+ 3/4"



D06FI-1/2A

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-1/2B

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, stainless steel filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4
Max. inlet pressure: 25bar
Filter bowl: stainless steel
Max. operating temp.: 70C


D06FI-1/2E

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1/2inch
DN size: 15mm
Flow capacity Kvs: 2.4
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-11/2

Honeywell Leadfree pressure reducing valve with balanced seat and set point scale, standard pattern, D06F-LFA
Spare Parts

Valve insert complete (without filter) for sizes 1 1/2"+ 2"



D06FI-11/2A

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-11/2B

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, stainless steel filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6
Max. inlet pressure: 25bar
Filter bowl: stainless steel
Max. operating temp.: 70C


D06FI-11/2E

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1 1/2inch
DN size: 40mm
Flow capacity Kvs: 12.6
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-11/4A

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-11/4B

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, stainless steel filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9
Max. inlet pressure: 25bar
Filter bowl: stainless steel
Max. operating temp.: 70C


D06FI-11/4E

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1 1/4inch
DN size: 32mm
Flow capacity Kvs: 5.9
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-1A

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-1B

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, stainless steel filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8
Max. inlet pressure: 25bar
Filter bowl: stainless steel
Max. operating temp.: 70C


D06FI-1E

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 1inch
DN size: 25mm
Flow capacity Kvs: 5.8
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-2A

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-2B

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, stainless steel filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12
Max. inlet pressure: 25bar
Filter bowl: stainless steel
Max. operating temp.: 70C


D06FI-2E

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

Without fittings, clear filter bowl
Connection Inlet/Outlet: external thread
Port diameter: 2inch
DN size: 50mm
Flow capacity Kvs: 12
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-3/4A

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scale
The adjustment spring is not in contact with the drinking water
Integral fine filter
Also available without fittings
Conforms to BSEN 1567
All materials are UBA conform
All materials are ACS approved
Medium type: drinking water
Body material: stainless steel
Spring bonnet material: synthetic material
Filter mesh: 0.16mm
Outlet pressure: 1.5...6bar
Preset outlet pressure: 3bar
Min. pressure drop: 1bar
Setpoint scale: yes
Balanced seat design: yes

With threaded male connections, clear filter bowl
Connection Inlet/Outlet: conn. set, ext. thread
Port diameter: 3/4inch
DN size: 20mm
Flow capacity Kvs: 3.1
Max. inlet pressure: 16bar
Filter bowl: clear
Max. operating temp.: 40C


D06FI-3/4B

Honeywell Stainless steel pattern pressure reducing valve with balanced seat, D06FI

According EN 806-2 pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.
Approvals: DVGW
WRAS (up to 23C)
Inlet pressure balancing - no influence on outlet pressure by fluctuating inlet pressure
Up to size 1 1/4" approved by LGA for low noise, Group 1 without limitations
The valve insert is of high quality synthetic material and can be fully exchanged
The outlet pressure is set by turning the adjustment knob
The set pressure is directly indicated on the set point scal