075041061

Honeywell Compact Line Rotary Actuator


Linkage of M6063L as replacement for M676A,C



0903403

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410
Accessories

Adapter for valve series V5077B/V5078B



14004406-120/U

Honeywell Pneumatic room temperature controller, TP970


Satin chrome cover



14004406-124/U

Honeywell Pneumatic room humidity sensor, HP971


Cover



14004406-300/U

Honeywell Pneumatic room temperature sensor, TP974


Cover without scale



14004458-001/U

Honeywell Pneumatic room temperature sensor, TP974


Spacer ring for wall mounting



43161276-001

Honeywell Pneumatic actuator, MP953
High Temperature Applications, the following bonnet extentions must be used with MP953 actuators when the flowing medium temperature is 150 to 220 degrees C, to give extra air circulation and less conduction of heat from the valve body to the actuator.

Used with V5049A up to 65mm, V5050A up to 80mm, V5328A 40mm to 80mm, V5329A 40mm to 80mm



43163162-001

Honeywell Pneumatic temperature sensor, LP914
Accessories

Stainless steel well, 380 mm 1/2" NPT



43191679-001

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 220/135 ohm operating range, for 20 mm models



43191679-002

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 220/135 ohm operating range, for 38 mm models



43191679-007

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 10 kohm operating range, for 20 mm models



43191679-008

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 10 kohm operating range, for 38 mm models



43191679-011

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Feedback potentiometer 10 kohm, operating range



43191679-012

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Feedback potentiometer 220 ohm operating range



43191680-002

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Dual end switches SPDT, adjustable (250 V~, 10 A)



43191680-005

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Dual end switches SPDT, adjustable (250 V~, 10 A)



43191680-205

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425
Accessories

Auxiliary switch (250 V~, 10 A)



43196000-001

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
High temperature kits for:

V5011R/S, V5013R/E; V5328A/V5329A DN15..32



43196000-002

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
High temperature kits for:

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80



43196000-038

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421
High temperature kits for:

V5015A/V5016A/V5025A/V5049A/V5050A/B/V5328A 38 mm



5112-11/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Linkage set for Damper actuators

Linkage set for VBG valves; DN15-32 for usage with S03.. actuators; DN15-50 for usage with N05.., S05.. actuators



5112-19/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement stem assembly for VBG valve, DN15, DN20



5112-20/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement stem assembly for VBG valve, DN25, DN32



5112-21/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN40, DN50 valves

Replacement stem assembly for VBG valve, DN40, DN50



5112-51/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN40, DN50 valves

Linkage set for VBG valves DN40, DN50 to M6061, M7061



5585100

Honeywell Two-way control valve PN16, conical sealing DN15/20, V5822A
Accessories

Spare adjustment cap (pack of 10)



AC-15FS

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

Soldering fitting for DN15 valve, pipe size 12 mm



AC-15FT

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN15 valve, pipe size R3/8"



AC-15TF

Honeywell Two-way control valve PN16, external threaded connections DN15-50, V5011E
Accessories

Internal threaded fitting for DN15 valve pipe size Rp 1/2"



AC-15TF-1

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Internal threaded fitting for VBG DN15 valve, pipe size Rp 1/2"



AC-20FS

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

Soldering fitting for DN20 valve, pipe size 15 mm



AC-20FT

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN20 valve, pipe size R1/2"



AC-20TF

Honeywell Two-way control valve PN16, external threaded connections DN15-50, V5011E
Accessories

Internal threaded fitting for DN20 valve pipe size Rp 3/4"



AC-25T

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN25 valve, pipe size R1"



AC-25TF

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN25 valve, pipe size Rp1"



AC-32T

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN32 valve, pipe size R11/4"



AC-32TF

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN32 valve, pipe size Rp11/4"



AC-40T

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN40 valve, pipe size R11/2"



AC-40TF

Honeywell Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN40 valve, pipe size Rp11/2"



AC-50TF

Honeywell Two-way control valve PN16, external threaded connections DN15-50, V5011E
Accessories

Internal threaded fitting for DN50 valve pipe size Rp 2"



ACN-15C

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Compression fitting for DN15 valve, pipe size 15 mm



ACN-15S

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Soldering fitting for DN15 valve, pipe size 12 mm



ACN-15T

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN15 valve, pipe size R3/8"



ACN-20C

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Compression fitting for DN20 valve, pipe size 22 mm



ACN-20S

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Soldering fitting for DN20 valve, pipe size 15 mm



ACN-20T

Honeywell Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN20 valve, pipe size R1/2"



ACS-15T

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

External threaded fitting for DN15 valve, pipe size R1/2"



ACS-15W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN15 valve, pipe size 1/2"



ACS-20T

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

External threaded fitting for DN20 valve, pipe size R3/4"



ACS-20W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN20 valve, pipe size 3/4"



ACS-25T

Honeywell Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN25 valve, pipe size R1"



ACS-25W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN25 valve, pipe size 1"



ACS-32T

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

External threaded fitting for DN32 valve, pipe size R1 1/4"



ACS-32W

Honeywell Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Accessories

Welding fitting for DN32 valve, pipe size 1 1/4"



AF00-B54

Honeywell Outdoor temperature sensor, Pt1000

Approvals: IEC751 class B
Temperature element: Pt1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Protection class: IP54


AF00-B65

Honeywell Outdoor temperature sensor, Pt1000

Approvals: IEC751 class B
Temperature element: Pt1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Protection class: IP65


AF01-B54

Honeywell Outdoor temperature sensor, Ni1000

Temperature element: Ni1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Protection class: IP54


AF01-B65

Honeywell Outdoor temperature sensor, Ni1000

Temperature element: Ni1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Protection class: IP65


AF10-B54

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC10k
Protection class: IP54
Comment: no


AF10-B65

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC10k
Protection class: IP65
Comment: no


AF20-B54

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP54
Comment: no


AF20-B65

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP65
Comment: no


AF20-B65-N

Honeywell Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP65
Comment: no logo


AGF1

Honeywell Flue gas temperature sensor

Steel plug in temperature sensor with mounting flange.
For flue gas temperature measurement.
Temperature element: Pt1000
Temperature range: 0...320C
Media temp. limit: temperatures up to 400 oC are allowable for short periods
Supplied with electrical cable with steel casing.
Mounting place: flue gas vent
Immersion depth: 120mm
Cable length: 1m


AKA3

Honeywell Heating, District Heating and Multi-Fuel OTC Controller, SMILE
Accessories for models with boiler burner output

Cable accessory



AQS-KAM-00

Honeywell Air duct CO2 and Temperature sensor, AQS

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Temperature range: 0...50C
Protection class: IP65 when probe mounted downwards, otherwise IP20
Mounting place: air duct
Immersion depth: 200mm
Power supply: 24Vac

Transmitter and additional passive temperature sensor
Output voltage: 0..10V: 0..2000 ppm
Temperature element: Pt1000
Wiring terminals: 6


AQS-KAM-01

Honeywell Air duct CO2 and Temperature sensor, AQS

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Temperature range: 0...50C
Protection class: IP65 when probe mounted downwards, otherwise IP20
Mounting place: air duct
Immersion depth: 200mm
Power supply: 24Vac

Transmitter and additional passive temperature sensor
Output voltage: 0..10V: 0..2000 ppm
Temperature element: Ni1000
Wiring terminals: 6


AQS-KAM-10

Honeywell Air duct CO2 and Temperature sensor, AQS

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Temperature range: 0...50C
Protection class: IP65 when probe mounted downwards, otherwise IP20
Mounting place: air duct
Immersion depth: 200mm
Power supply: 24Vac

Transmitter and additional passive temperature sensor
Output voltage: 0..10V: 0..2000 ppm
Temperature element: NTC10k
Wiring terminals: 6


AQS-KAM-20

Honeywell Air duct CO2 and Temperature sensor, AQS

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Temperature range: 0...50C
Protection class: IP65 when probe mounted downwards, otherwise IP20
Mounting place: air duct
Immersion depth: 200mm
Power supply: 24Vac

Transmitter and additional passive temperature sensor
Output voltage: 0..10V: 0..2000 ppm
Temperature element: NTC20k
Wiring terminals: 6


AQS-KAM-RH-V

Honeywell Air duct CO2, Temperature and R.H. transmitter, AQS

For sensing or controlling of CO2 concentration, temperature and Relative Humidity measurement in buildings.
Output voltage: 3 outputs 0..10V:
0..2000 ppm
0..50oC
10..90 %rh
Temperature range: 0...50C
R.H. range: 10...90%rh
Protection class: IP65 when probe mounted downwards, otherwise IP20
Mounting place: air duct
Immersion depth: 200mm
Power supply: 24Vac
Wiring terminals: 6


AQS71-KAM-T

Honeywell Air duct CO2 and Temperature sensor, AQS

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Temperature range: 0...50C
Protection class: IP65 when probe mounted downwards, otherwise IP20
Mounting place: air duct
Immersion depth: 200mm
Power supply: 24Vac

Transmitters only
Output voltage: 0..10V: 0..50oC; 0..10V: 0..2000 ppm
Temperature element: no
Wiring terminals: 5


AS2

Honeywell Actuator for V5421B1090
Optional accessories

End switch



ASL453

Honeywell Electronical air flow switch for air (ASL)

Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit type ASL...
For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever flow processes in air or neutral gases have to be detected.
Protection class: sensor: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable from 0,1..20 m/s air speed
Media temperature at sensor: -20..100 oC.

Evaluation Unit
Mounting place: universal
Immersion depth: no
Power supply: 230Vac


ASL453/24

Honeywell Electronical air flow switch for air (ASL)

Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit type ASL...
For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever flow processes in air or neutral gases have to be detected.
Protection class: sensor: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable from 0,1..20 m/s air speed
Media temperature at sensor: -20..100 oC.

Evaluation Unit
Mounting place: universal
Immersion depth: no
Power supply: 24Vac


ASW454

Honeywell Electronical flow switch for liquid (ASW)

The flow in fluids can be monitored reliably with flow sensors SWF62 and SWF62L and evaluation unit ASW454. The sensitivity can be adjusted accurately with a rough and fine potentiometer. The switching state is indicated by LED. The sensor element must be located in the flow.
Protection class: sensor: IP65; evaluation unit: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable, lowest 0,03 m/s fluid speed
For sensor:
media temperature 0..80 oC
sensing element steel

Evaluation unit
Power supply: 230Vac
Mounting place: universal
Immersion depth: no
Connection diameter: no


ASW454/24

Honeywell Electronical flow switch for liquid (ASW)

The flow in fluids can be monitored reliably with flow sensors SWF62 and SWF62L and evaluation unit ASW454. The sensitivity can be adjusted accurately with a rough and fine potentiometer. The switching state is indicated by LED. The sensor element must be located in the flow.
Protection class: sensor: IP65; evaluation unit: IP32
Output signal: evaluation unit: relay SPST 8A, 250Vac, switch point adjustable, lowest 0,03 m/s fluid speed
For sensor:
media temperature 0..80 oC
sensing element steel

Evaluation unit
Power supply: 24Vac
Mounting place: universal
Immersion depth: no
Connection diameter: no


ATU2040A

Honeywell Rotary Actuator
Mounting kit for non-Honeywell valves

Universal kit for almost all valves



AV-D-10

Honeywell Air velocity sensor

Media: Air, 0 to 10m/s (default); selectable by link for 0 to 15m/s or 0 to 20m/s
Response time: 4s (default) or 1s selectable by link
Mounting place: air duct
Protection class: IP 65 Housing
Humidity 5..95 %rh, non-condensing
Output signal: 2..10Vdc + 4..20mA


Mounting: in duct


AV-R-10

Honeywell Air velocity sensor

Media: Air, 0 to 10m/s (default); selectable by link for 0 to 15m/s or 0 to 20m/s
Response time: 4s (default) or 1s selectable by link
Mounting place: air duct
Protection class: IP 65 Housing
Humidity 5..95 %rh, non-condensing
Output signal: 2..10Vdc + 4..20mA


Mounting: remote


BACA-A

Honeywell Room Controller ComfortPoint Open
Tools for Commissioning

Wireless Adapter



C7085A1006

Honeywell Air duct temperature sensor, average measurement, Pt1000

Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four rod clips with screws.
For application in ducts where large temperature gradients can occur.
The 3 meters flexible rod has four sensors positioned along the length of the rod.
Temperature element: 4 x Pt1000
Temperature range: -30...70C
Mounting place: air duct
Wiring terminals: 2


C7085A1014

Honeywell Air duct temperature sensor, average measurement, NTC

Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four rod clips with screws.
For application in ducts where large temperature gradients can occur.
The 3 meters flexible rod has four sensors positioned along the length of the rod.
Temperature element: 4 x NTC20k
Temperature range: -30...70C
Mounting place: air duct
Wiring terminals: 2


C7110A1010

Honeywell Air quality sensor

For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as furniture, carpets, paint, glue, etc.
Protection class: III as per EN60730-1I IP30 as per EN60529
Output signal: 0..10Vdc
Adjustable output offset and LED display
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7110C1001A

Honeywell Room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration in buildings.
LED functions: operation as CO2 indicator
Output signal: CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm
temperature: 0..10 V
Automatic baseline calibration, and quick calibration options.
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7110D1009A

Honeywell Room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
LED functions: operation as occupancy indicator
Output signal: CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm
Temperature setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.
Automatic baseline calibration, and quick calibration options.
Temperature element: NTC20k
Temperature range: 10...35C
Setpoint knob: -5...5C
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


CABLE-CONTROL

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Control Spares
Product description: Set of linking cable for HVAC400 older than March 2018
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


CARE-80-BASIC

Honeywell CARE software

Excel Computer Aided Regulation Engineering ('CARE') software provides graphic tools to create data files and control programs for Excel 50, Excel 80, Excel 100, Excel 500, Excel 600, EXCEL 800, Excel-WEB and Open Point Server Controllers. CARE is additionally capable to replace a LON Engineering Tool for all LonMark compliant devices.
CARE can be used to program any application with the free programmable Controllers from Honeywell.
CARE supports:
For C-Bus System: XL50, Excel 80, Excel 100, XL500 (to be programmed as EXCEL 500), XL500, Excel 600 and XL800 Controllers.
For BACnet System: XLWeb and XLWEB II Controllers

CARE New Licenses (delivered with protection plug)
Product description: CARE 10 Basic Version for XL5000 System engineering (XL50, XL100, XC5010C, XCL8010, XCL5010, EXCEL-WEB) with LON engineering


CARE-80-FULL

Honeywell CARE software

Excel Computer Aided Regulation Engineering ('CARE') software provides graphic tools to create data files and control programs for Excel 50, Excel 80, Excel 100, Excel 500, Excel 600, EXCEL 800, Excel-WEB and Open Point Server Controllers. CARE is additionally capable to replace a LON Engineering Tool for all LonMark compliant devices.
CARE can be used to program any application with the free programmable Controllers from Honeywell.
CARE supports:
For C-Bus System: XL50, Excel 80, Excel 100, XL500 (to be programmed as EXCEL 500), XL500, Excel 600 and XL800 Controllers.
For BACnet System: XLWeb and XLWEB II Controllers

CARE New Licenses (delivered with protection plug)
Product description: CARE 10 All Features including RACL and ASPECD Support


CARE-80-LNS

Honeywell CARE software

Excel Computer Aided Regulation Engineering ('CARE') software provides graphic tools to create data files and control programs for Excel 50, Excel 80, Excel 100, Excel 500, Excel 600, EXCEL 800, Excel-WEB and Open Point Server Controllers. CARE is additionally capable to replace a LON Engineering Tool for all LonMark compliant devices.
CARE can be used to program any application with the free programmable Controllers from Honeywell.
CARE supports:
For C-Bus System: XL50, Excel 80, Excel 100, XL500 (to be programmed as EXCEL 500), XL500, Excel 600 and XL800 Controllers.
For BACnet System: XLWeb and XLWEB II Controllers

CARE New Licenses (delivered with protection plug)
Product description: CARE 10 additionally with LNS Turbo License with one device credit


CDS2000A3000C

Honeywell CO2 Gas detector for Duct application, CDS2000

CDS2000A3000C sensor and controller measures the carbon dioxide gas concentration in the ventilated duct. This product is used in ventilation and air conditioning systems to control the amount of fresh outdoor air supplied to maintain acceptable levels of CO2 in the space.
Specification
Sensing method: NDIR (Non-dispersive infrared)
Detect range: 0-2000 ppm
Power supply: 24 Vac/dc
Analog output: 0-10 Vdc (default) or 0-20 mA (selectable by jumper setting)
Coverage area: approximately 100 m2
Response time: Within 120 sec (90% step)
Protection class: IP63
Alarm relay: SPST relay, normally open, 1A/24Vdc contact rating; activated at greater than 1000ppm, deactivated at less than 900ppm


COMP-IP21-KIT1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive HVAC232/402, size MI1
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-IP21-KIT2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive HVAC232/402, size MI2
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-IP21-KIT3

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive HVAC232/402, size MI3
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-LOADER

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive PC connection tools and cables
Product description: SmartDrive Compact Parameter download/upload and PC interface tool with cable for USB connection to PC
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-LOADER-NC

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive PC connection tools and cables
Product description: SmartDrive Compact Parameter download/upload and PC interface tool without cable
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-NEMA1-KIT1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive HVAC232/402, size MI1
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-NEMA1-KIT2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive HVAC232/402, size MI2
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-NEMA1-KIT3

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive HVAC232/402, size MI3
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


CONTROL-BOARD1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Control Spares
Product description: Control box and boards for HVAC400 drives
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


CPO-CORE

Honeywell Controllers with ROHS II Certificate


BACNET ROUTER



CPO-DIO

Honeywell Controllers with ROHS II Certificate


CPO EXIO EXP BRD/MSTP CONTR. 8UI 8DI 16DO



CPO-EXPIO

Honeywell Controllers with ROHS II Certificate


CPO EXIO EXP BRD 8UI 6DI 6AO 4DO



CPO-FTCL

Honeywell Controllers with ROHS II Certificate


CPO FCU TERM. COVER BULK PCK.



CPO-IO830A

Honeywell Controllers with ROHS II Certificate


Mixed I/O Module



CPO-IPC

Honeywell Controllers with ROHS II Certificate


CPO IPC PLANT CONTR. 8UI 6DI 6AO 4DO



CPO-PC-6A

Honeywell Controllers with ROHS II Certificate


CPO Plant Controller



CPO-RL1

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 2
UI: 6
Relay outputs: 1
Triac: 2
Control software: config/free progr.


CPO-RL2

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 2
UI: 6
Relay outputs: 4
Triac: 4
Control software: config/free progr.


CPO-RL3

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 2
UI: 6
Relay outputs: 4
Triac: 4
Control software: config/free progr.


CPO-RL4

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h


CPO-RL5

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h; removable terminals


CPO-RL6

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h


CPO-RL7U

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: data retention 72h; watchdog relay; ambient temp. -40..65C


CPO-RL8

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

LARGE Housing (189x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 6
UI: 10
Relay outputs: 4
Triac: 4
Control software: config/free progr.
Note: with lighting support


CPO-RS1

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 3
UI: 3
Relay outputs: 0
Triac: 0
Control software: config/free progr.


CPO-RS2

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 1
UI: 3
Relay outputs: 0
Triac: 0
Control software: conf. only


CPO-RS3

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 0
UI: 3
Relay outputs: 3
Triac: 2
Control software: conf. only


CPO-RS4

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 230V; max. of all 24Vac outputs 300 mA
AO: 4
UI: 4
Relay outputs: 4
Triac: 2
Control software: config/free progr.


CPO-RS5

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 4
UI: 4
Relay outputs: 4
Triac: 2
Control software: config/free progr.


CPO-RS6

Honeywell Room Controller ComfortPoint Open

The CPO Room Controller is a BACnet-compliant HVAC room controller offering comprehensive installation advantages, such as universal mounting options and the capability to directly connect and power field devices. Fast and easy single-person commissioning on smartphone and tablet is possible via the RoomUp app.
Proven configurable applications can be used in 2- and 4-pipe systems. Fan coil units, chilled ceilings, hydronic and underfloor heating installations, air quality control, and a mix of these applications can be covered in a single controller. To safeguard investments and for full flexibility to fulfill customer specific requirements, the controller can be freely programmed with CPO Studio as well.
Hardware inputs: measurement of temperature, relative humidity, pressure etc.
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays (N.O.)
triacs (24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell sensors TR40/TR42
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)

SMALL Housing (162x110x57,5mm); Power supply 24V; max. of all 24Vac outputs 600 mA
AO: 1
UI: 3
Relay outputs: 0
Triac: 2
Control software: conf. only


CPO-SPC

Honeywell Controllers with ROHS II Certificate


CPO SM POINT CONTR. 6UI 4DI 3AO 8DO



CPO-VAV

Honeywell Controllers with ROHS II Certificate


CPO VAV CONTR. 6UI 4DI 3AO 8DO



CPO-VAV2A

Honeywell Controllers with ROHS II Certificate


CPO VAV CONTR. INTEGRAL ACT.



CRT12

Honeywell Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 288 VA


CRT2

Honeywell Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 48 VA


CRT6

Honeywell Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 144 VA


CRT6-12

Honeywell Transformer, 2 secondary windings

Protection class: IP00
Input voltage: 230 V, 50Hz
Output voltage: 2 x 24Vac, separated
With mains fuse. VDE0551 mark.


Model: 150/250 VA


CRT6-6

Honeywell Transformer, 2 secondary windings

Protection class: IP00
Input voltage: 230 V, 50Hz
Output voltage: 2 x 24Vac, separated
With mains fuse. VDE0551 mark.


Model: 144/144 VA


DCE1

Honeywell EXCEL 5000 operators panel, XI582
DIN plugs

5-pole DIN plug female for cabinet door mounting



DCE2

Honeywell EXCEL 5000 operators panel, XI582
DIN plugs

5-pole DIN plug male



DCM025

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.04...0.25bar
Adjustable switching differential: no
Switching differential: 0.03bar
Max. pressure: 6bar
Sensing element material: Copper + Brass


DCM06

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: no
Switching differential: 0.04bar
Max. pressure: 6bar
Sensing element material: Copper + Brass


DCM1

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: no
Switching differential: 0.04bar
Max. pressure: 6bar
Sensing element material: Copper + Brass


DCM10

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 1...10bar
Adjustable switching differential: no
Switching differential: 0.3bar
Max. pressure: 25bar
Sensing element material: 1.4104 + 1.4571


DCM1000

Honeywell Pressure switch for liquid, gas, small range (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 10...100mbar
Switching differential: 12mbar
Max. pressure: 10bar
Sensing element material: Perbunan + Brass


DCM16

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: no
Switching differential: 0.5bar
Max. pressure: 25bar
Sensing element material: 1.4104 + 1.4571


DCM25

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 4...25bar
Adjustable switching differential: no
Switching differential: 1bar
Max. pressure: 60bar
Sensing element material: 1.4104 + 1.4571


DCM3

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: no
Switching differential: 0.1bar
Max. pressure: 16bar
Sensing element material: 1.4104 + 1.4571


DCM40

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 8...40bar
Adjustable switching differential: no
Switching differential: 1.3bar
Max. pressure: 60bar
Sensing element material: 1.4104 + 1.4571


DCM4016

Honeywell Pressure switch for liquid, gas, small range (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 1...16mbar
Switching differential: 2mbar
Max. pressure: 1bar
Sensing element material: Perbunan + 1.4301


DCM4025

Honeywell Pressure switch for liquid, gas, small range (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 4...25mbar
Switching differential: 2mbar
Max. pressure: 1bar
Sensing element material: Perbunan + 1.4301


DCM6

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: no
Switching differential: 0.15bar
Max. pressure: 16bar
Sensing element material: 1.4104 + 1.4571


DCM625

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: no
Switching differential: 0.25bar
Max. pressure: 25bar
Sensing element material: 1.4104 + 1.4571


DCM63

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 16...63bar
Adjustable switching differential: no
Switching differential: 2bar
Max. pressure: 130bar
Sensing element material: 1.4104 + 1.4571


DCM63-406

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 40...75bar
Adjustable switching differential: no
Switching differential: 2bar
Max. pressure: 130bar
Sensing element material: 1.4104 + 1.4571


DCMV025

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.04...0.25bar
Adjustable switching differential: 0.03...0.4bar
Switching differential: no
Max. pressure: 6bar
Sensing element material: Copper + Brass


DCMV06

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: 0.04...0.5bar
Switching differential: no
Max. pressure: 6bar
Sensing element material: Copper + Brass


DCMV1

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: 0.07...0.55bar
Switching differential: no
Max. pressure: 6bar
Sensing element material: Copper + Brass


DCMV10

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 1...10bar
Adjustable switching differential: 0.5...2.8bar
Switching differential: no
Max. pressure: 25bar
Sensing element material: 1.4104 + 1.4571


DCMV16

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: 0.7...3.5bar
Switching differential: no
Max. pressure: 25bar
Sensing element material: 1.4104 + 1.4571


DCMV25

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 4...25bar
Adjustable switching differential: 1.3...6bar
Switching differential: no
Max. pressure: 60bar
Sensing element material: 1.4104 + 1.4571


DCMV3

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: 0.15...1.5bar
Switching differential: no
Max. pressure: 16bar
Sensing element material: 1.4104 + 1.4571


DCMV40

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 8...40bar
Adjustable switching differential: 2.6...6.6bar
Switching differential: no
Max. pressure: 60bar
Sensing element material: 1.4104 + 1.4571


DCMV6

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: 0.25...2bar
Switching differential: no
Max. pressure: 16bar
Sensing element material: 1.4104 + 1.4571


DCMV63

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 16...63bar
Adjustable switching differential: 3...10bar
Switching differential: no
Max. pressure: 130bar
Sensing element material: 1.4104 + 1.4571


DCPSU-24-1.3

Honeywell DC Power Supply

Single phase switched power supply 24 Vdc
Output short circuit protection
DIN rail mounting
2 x 24 V push in terminals
Voltage adjustment


Product description: DC Power Supply 1,3A


DCPSU-24-2.5

Honeywell DC Power Supply

Single phase switched power supply 24 Vdc
Output short circuit protection
DIN rail mounting
2 x 24 V push in terminals
Voltage adjustment


Product description: DC Power Supply 2,5A


DCPSU-24-4

Honeywell DC Power Supply

Single phase switched power supply 24 Vdc
Output short circuit protection
DIN rail mounting
2 x 24 V push in terminals
Voltage adjustment


Product description: DC Power Supply 4A


DDCM014

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: -0.1...0.4bar
Switching differential: 0.15bar
Max. pressure: 15bar
Sensing element material: 1.4305 + 1.4571


DDCM1

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.13bar
Max. pressure: 15bar
Sensing element material: 1.4305 + 1.4571


DDCM16

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 3...16bar
Switching differential: 0.6bar
Max. pressure: 25bar
Sensing element material: 1.4305 + 1.4571


DDCM1602

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 0.02...0.16bar
Switching differential: 0.02bar
Max. pressure: 3bar
Sensing element material: Perbunan + Aluminium


DDCM252

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 0.004...0.025bar
Switching differential: 0.002bar
Max. pressure: 0.5bar
Sensing element material: Perbunan + Aluminium


DDCM4

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 1...4bar
Switching differential: 0.2bar
Max. pressure: 25bar
Sensing element material: 1.4305 + 1.4571


DDCM6

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 15bar
Sensing element material: 1.4305 + 1.4571


DDCM6002

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.035bar
Max. pressure: 3bar
Sensing element material: Perbunan + Aluminium


DDCM662

Honeywell Differential pressure switch for liquid, gas (DDCM)

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-205: maximum limiter with reclosing lock-out, interlocking with increasing pressure
-206: Minimum limiter with reclosing lock-out, interlocking with falling pressure
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2


Pressure adjustment range: 0.01...0.06bar
Switching differential: 0.015bar
Max. pressure: 1.5bar
Sensing element material: Perbunan + Aluminium


DGM06A

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 25mbar
Max. pressure: 2bar
Sensing element material: Copper + Brass


DGM1A

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 40mbar
Max. pressure: 3bar
Sensing element material: Copper + Brass


DGM306A

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.015...0.06bar
Switching differential: 6mbar
Max. pressure: 0.8bar
Sensing element material: Copper + Brass


DGM310A

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.02...0.1bar
Switching differential: 7mbar
Max. pressure: 0.8bar
Sensing element material: Copper + Brass


DGM325A

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.04...0.25bar
Switching differential: 10mbar
Max. pressure: 0.8bar
Sensing element material: Copper + Brass


DGM506

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.015...0.06bar
Switching differential: 8mbar
Max. pressure: 5bar
Sensing element material: 1.4104 + 1.4571


DGM516

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.04...0.16bar
Switching differential: 12mbar
Max. pressure: 5bar
Sensing element material: 1.4104 + 1.4571


DGM525

Honeywell Pressure monitor for fuel gases (DGM)

For overpressure monitoring of fuel gases.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
-574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
-577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-i
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.25bar
Switching differential: 20mbar
Max. pressure: 5bar
Sensing element material: 1.4104 + 1.4571


DMW

Honeywell Accessories for Pressure Switches / Transmitters
Accessories

Pressure surge reducer



DNM025

Honeywell Pressure switch for liquid, gas (DCM)

For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL 2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.04...0.25bar
Adjustable switching differential: no
Switching differential: 0.03bar
Max. pressure: 6bar
Sensing element material: 1.4104 + 1.4571


DNS025-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 0.04...0.25bar
Adjustable switching differential: no
Switching differential: 0.03bar
Max. pressure: 6bar


DNS06-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: no
Switching differential: 0.04bar
Max. pressure: 6bar


DNS06-203

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Adjustable pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: 0.08...0.4bar
Switching differential: no
Max. pressure: 6bar


DNS1-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: no
Switching differential: 0.06bar
Max. pressure: 6bar


DNS10-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 1...10bar
Adjustable switching differential: no
Switching differential: 0.3bar
Max. pressure: 16bar


DNS10-203

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Adjustable pressure hysteresis
Pressure adjustment range: 1...10bar
Adjustable switching differential: 0.45...2.5bar
Switching differential: no
Max. pressure: 16bar


DNS16-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: no
Switching differential: 0.5bar
Max. pressure: 25bar


DNS16-203

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Adjustable pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: 0.8...3.5bar
Switching differential: no
Max. pressure: 25bar


DNS3-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: no
Switching differential: 0.1bar
Max. pressure: 16bar


DNS3-203

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Adjustable pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: 0.15...1.5bar
Switching differential: no
Max. pressure: 16bar


DNS6-201

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: no
Switching differential: 0.15bar
Max. pressure: 16bar


DNS6-203

Honeywell Pressure switch for aggressive liquid, gas (DNS)

For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-301: terminal connection housing, IP65
-307: two microswitches, switching in parallel or in succession, fixed switching interval, terminal connection case, IP65
-217: two microswitches, 1 plug, switching in succession, adjustable switching interval
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-351: protection class IP65 and switching housing with surface protection (chemical version)
-513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: SIL2 according IEC 61508-2
Sensing element material: 1.4571

Adjustable pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: 0.25...2bar
Switching differential: no
Max. pressure: 16bar


DPS1000

Honeywell Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 200...1000Pa
Switching differential: 1mbar


DPS200

Honeywell Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 20...200Pa
Switching differential: 0.1mbar


DPS2500

Honeywell Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 500...2500Pa
Switching differential: 1.5mbar


DPS400

Honeywell Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 40...400Pa
Switching differential: 0.2mbar


DPS500

Honeywell Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 50...500Pa
Switching differential: 0.2mbar


DPSK

Honeywell Differential pressure switch for air (DPS)
Accessories

Duct Kit, including 2m silicone-hose and 2 joining pipes DPSJ with screws



DPSL

Honeywell Differential pressure switch for air (DPS)
Accessories

L-shaped bracket for installation turned by 90o, e.g. in the ceiling area



DPTA25

Honeywell Differential pressure transmitter for air (DPTA)

Differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Output signal: 0-10 V and 4-20 mA
Automatic zeroing for all ranges
3-wire connection
Duct Kit DPSK included in delivery of single package

Single range models
Pressure range: 0...25Pa
Display: no


DPTA25D

Honeywell Differential pressure transmitter for air (DPTA)

Differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Output signal: 0-10 V and 4-20 mA
Automatic zeroing for all ranges
3-wire connection
Duct Kit DPSK included in delivery of single package

Single range models
Pressure range: 0...25Pa
Display: yes


DPTA25S

Honeywell Differential pressure transmitter for air (DPTA)

Differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Output signal: 0-10 V and 4-20 mA
Automatic zeroing for all ranges
3-wire connection
Duct Kit DPSK included in delivery of single package

Single range models
Pressure range: -25...25Pa
Display: no


DPTA25SD

Honeywell Differential pressure transmitter for air (DPTA)

Differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Output signal: 0-10 V and 4-20 mA
Automatic zeroing for all ranges
3-wire connection
Duct Kit DPSK included in delivery of single package

Single range models
Pressure range: -25...25Pa
Display: yes


DPTAQ8

Honeywell Differential pressure transmitter for air (DPTA)

Differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Output signal: 0-10 V and 4-20 mA
Automatic zeroing for all ranges
3-wire connection
Duct Kit DPSK included in delivery of single package

8-range models; range selectable by rotary switch
Pressure range: Selectable...-50/+50, -10/+100, -250/+250, -500/+500, -1000/+1000, 0-250, 0-500, 0-1000Pa
Display: no


DPTAQ8D

Honeywell Differential pressure transmitter for air (DPTA)

Differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Output signal: 0-10 V and 4-20 mA
Automatic zeroing for all ranges
3-wire connection
Duct Kit DPSK included in delivery of single package

8-range models; range selectable by rotary switch
Pressure range: Selectable...-50/+50, -10/+100, -250/+250, -500/+500, -1000/+1000, 0-250, 0-500, 0-1000Pa
Display: yes


DPTE100

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...100/250Pa
Max. pressure: 20kPa


DPTE1000

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...1000/2500Pa
Max. pressure: 40kPa


DPTE1000D

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...1000/2500Pa
Max. pressure: 40kPa


DPTE1000S

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -1000...1000Pa
Max. pressure: 20kPa


DPTE1000SD

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -1000...1000Pa
Max. pressure: 20kPa


DPTE1002

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...1000/2500Pa
Max. pressure: 40kPa


DPTE100D

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...100/250Pa
Max. pressure: 20kPa


DPTE100S

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -100...100Pa
Max. pressure: 20kPa


DPTE100SD

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -100...100Pa
Max. pressure: 20kPa


DPTE102

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...100/250Pa
Max. pressure: 20kPa


DPTE102S

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: -100...100Pa
Max. pressure: 20kPa


DPTE250

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...250/500Pa
Max. pressure: 20kPa


DPTE250D

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...250/500Pa
Max. pressure: 20kPa


DPTE252

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...250/500Pa
Max. pressure: 20kPa


DPTE500

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...500/1000Pa
Max. pressure: 20kPa


DPTE5000

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...5000/10000Pa
Max. pressure: 60kPa


DPTE5000D

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...5000/10000Pa
Max. pressure: 60kPa


DPTE5002

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...5000/10000Pa
Max. pressure: 60kPa


DPTE500D

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...500/1000Pa
Max. pressure: 20kPa


DPTE500S

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -500...500Pa
Max. pressure: 20kPa


DPTE500SD

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -500...500Pa
Max. pressure: 20kPa


DPTE502

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...500/1000Pa
Max. pressure: 20kPa


DPTE50S

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -50...50Pa
Max. pressure: 20kPa


DPTE50SD

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -50...50Pa
Max. pressure: 20kPa


DPTE52S

Honeywell Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: -50...50Pa
Max. pressure: 20kPa


DR100FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 100mm
Kvs value: 160
Max. delta P: 100kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 30Nm
Port connection: flanges DIN2531


DR100GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 100mm
Kvs value: 160
Max. delta P: 100kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 30Nm
Port connection: flanges DIN2531


DR125FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 125mm
Kvs value: 250
Max. delta P: 70kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 30Nm
Port connection: flanges DIN2531


DR125GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 125mm
Kvs value: 250
Max. delta P: 70kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 30Nm
Port connection: flanges DIN2531


DR15-2GMLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 15mm
Kvs value: 2.5
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR150FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 150mm
Kvs value: 630
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR150GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 150mm
Kvs value: 630
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR15GMLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 15mm
Kvs value: 4
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR15MA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 15mm
Kvs value: 4
Max. delta P: 100kPa
Torque for max. delta P: 10Nm
Torque for reduced delta P: 10Nm
Port connection: internal threads


DR200FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 200mm
Kvs value: 1600
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR200GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 200mm
Kvs value: 1600
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR200GFLA1

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 200mm
Kvs value: 1000
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR20GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 20mm
Kvs value: 6.3
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR20GMLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 20mm
Kvs value: 6.3
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR20MA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 20mm
Kvs value: 6.3
Max. delta P: 100kPa
Torque for max. delta P: 10Nm
Torque for reduced delta P: 10Nm
Port connection: internal threads


DR25GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 25mm
Kvs value: 10
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR25GMLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 25mm
Kvs value: 10
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR25MA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 25mm
Kvs value: 10
Max. delta P: 100kPa
Torque for max. delta P: 10Nm
Torque for reduced delta P: 10Nm
Port connection: internal threads


DR32GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 32mm
Kvs value: 16
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR32GMLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 32mm
Kvs value: 16
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR32MA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 32mm
Kvs value: 16
Max. delta P: 100kPa
Torque for max. delta P: 10Nm
Torque for reduced delta P: 10Nm
Port connection: internal threads


DR40FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 40mm
Kvs value: 25
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 10Nm
Port connection: flanges DIN2531


DR40GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 40mm
Kvs value: 25
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR40GMLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 40mm
Kvs value: 25
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR40MA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 40mm
Kvs value: 25
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 10Nm
Port connection: internal threads


DR50FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 50mm
Kvs value: 40
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR50GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 50mm
Kvs value: 40
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR65FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 65mm
Kvs value: 63
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR65GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 65mm
Kvs value: 63
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR80FA

Honeywell Three-way rotary valve PN6, angle pattern, DR

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DR
Valve type: 3-way rotary mixing, angle
Medium type: water
Materials: body cast iron GG20, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 80mm
Kvs value: 100
Max. delta P: 100kPa
Torque for max. delta P: 30Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR80GFLA

Honeywell Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN6
Reduced delta P: 40kPa

Flanges
DN size: 80mm
Kvs value: 100
Max. delta P: 100kPa
Torque for max. delta P: 30Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DRA-02L

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXL door installation set for display panel, 2m cable
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


DRA-04B

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXS door installation set for display panel, 4m cable
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


DRA-04L

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXL door installation set for display panel, 4m cable
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


DRA02B

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXS door installation set for display panel, 2m cable
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


DRF20-S

Honeywell Room temperature sensor, NTC20k

Protection class: IP30
Temperature range: 10...40C
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


Temperature element: 2 x NTC20k
Wiring terminals: 3


DRR25-10

Honeywell Three-way rotary valve PN10, for systems with oxygen diffusion

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
For applications with sludge deposition and for panel heating (e.g. underfloor and ceiling heating systems) with oxygen diffusion.
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body red brass, inner parts chrome plated cast iron
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Thermal insulation package included.
DN size: 25mm
Max. delta P: 100kPa
Torque for max. delta P: 20Nm


Kvs value: 10


DRR25-16

Honeywell Three-way rotary valve PN10, for systems with oxygen diffusion

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
For applications with sludge deposition and for panel heating (e.g. underfloor and ceiling heating systems) with oxygen diffusion.
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body red brass, inner parts chrome plated cast iron
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Thermal insulation package included.
DN size: 25mm
Max. delta P: 100kPa
Torque for max. delta P: 20Nm


Kvs value: 16


DRR25-2.5

Honeywell Three-way rotary valve PN10, for systems with oxygen diffusion

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
For applications with sludge deposition and for panel heating (e.g. underfloor and ceiling heating systems) with oxygen diffusion.
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body red brass, inner parts chrome plated cast iron
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Thermal insulation package included.
DN size: 25mm
Max. delta P: 100kPa
Torque for max. delta P: 20Nm


Kvs value: 2.5


DRR25-4.0

Honeywell Three-way rotary valve PN10, for systems with oxygen diffusion

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
For applications with sludge deposition and for panel heating (e.g. underfloor and ceiling heating systems) with oxygen diffusion.
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body red brass, inner parts chrome plated cast iron
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Thermal insulation package included.
DN size: 25mm
Max. delta P: 100kPa
Torque for max. delta P: 20Nm


Kvs value: 4


DRR25-6.3

Honeywell Three-way rotary valve PN10, for systems with oxygen diffusion

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
For applications with sludge deposition and for panel heating (e.g. underfloor and ceiling heating systems) with oxygen diffusion.
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body red brass, inner parts chrome plated cast iron
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Thermal insulation package included.
DN size: 25mm
Max. delta P: 100kPa
Torque for max. delta P: 20Nm


Kvs value: 6.3


DRU25-10

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 10


DRU25-16

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 16


DRU25-2.5

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 2.5


DRU25-4.0

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 4


DRU25-6.3

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 6.3


DRU32-10

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 32mm
Kvs value: 10


DRU32-16

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 32mm
Kvs value: 16


DRU32-25

Honeywell Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Nominal pressure: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 32mm
Kvs value: 25


DWAM06

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: no
Switching differential: 0.04bar
Max. pressure: 5bar


DWAM06-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.04bar
Max. pressure: 5bar


DWAM1

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: no
Switching differential: 0.05bar
Max. pressure: 5bar


DWAM1-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.05bar
Max. pressure: 5bar


DWAM16

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: no
Switching differential: 0.4bar
Max. pressure: 20bar


DWAM16-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.4bar
Max. pressure: 20bar


DWAM16-577

Honeywell Maximum pressure limiter (Ex-i) of 'special construction' with internal interlock (DWAM...-577)

Maximum pressure limiter with selfmonitoring sensor and internal interlock for steam and hot water. Microswith not positive opening. Contacts: silver alloy. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.4bar
Max. pressure: 20bar


DWAM2.5-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 0.4...2.5bar
Switching differential: 0.07bar
Max. pressure: 5bar


DWAM2.5-577

Honeywell Maximum pressure limiter (Ex-i) of 'special construction' with internal interlock (DWAM...-577)

Maximum pressure limiter with selfmonitoring sensor and internal interlock for steam and hot water. Microswith not positive opening. Contacts: silver alloy. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 0.4...2.5bar
Switching differential: 0.07bar
Max. pressure: 5bar


DWAM32

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 6...32bar
Adjustable switching differential: no
Switching differential: 1.2bar
Max. pressure: 45bar


DWAM32-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 6...32bar
Switching differential: 1.2bar
Max. pressure: 45bar


DWAM32-577

Honeywell Maximum pressure limiter (Ex-i) of 'special construction' with internal interlock (DWAM...-577)

Maximum pressure limiter with selfmonitoring sensor and internal interlock for steam and hot water. Microswith not positive opening. Contacts: silver alloy. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 6...32bar
Switching differential: 1.2bar
Max. pressure: 45bar


DWAM6

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 1.2...6bar
Adjustable switching differential: no
Switching differential: 0.2bar
Max. pressure: 10bar


DWAM6-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 1.2...6bar
Switching differential: 0.2bar
Max. pressure: 10bar


DWAM6-577

Honeywell Maximum pressure limiter (Ex-i) of 'special construction' with internal interlock (DWAM...-577)

Maximum pressure limiter with selfmonitoring sensor and internal interlock for steam and hot water. Microswith not positive opening. Contacts: silver alloy. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 1.2...6bar
Switching differential: 0.2bar
Max. pressure: 10bar


DWAM625

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 1.2...6bar
Adjustable switching differential: no
Switching differential: 0.25bar
Max. pressure: 20bar


DWAM625-576

Honeywell Maximum pressure monitor (Ex-i) of 'special construction' (DWAM...-576)

Maximum pressure monitor with selfmonitoring sensor for steam and hot water. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 1.2...6bar
Switching differential: 0.25bar
Max. pressure: 20bar


DWAM625-577

Honeywell Maximum pressure limiter (Ex-i) of 'special construction' with internal interlock (DWAM...-577)

Maximum pressure limiter with selfmonitoring sensor and internal interlock for steam and hot water. Microswith not positive opening. Contacts: silver alloy. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro-H
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 1.2...6bar
Switching differential: 0.25bar
Max. pressure: 20bar


DWAMV1

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: 0.12...0.6bar
Switching differential: no
Max. pressure: 5bar


DWAMV16

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: 0.8...2.5bar
Switching differential: no
Max. pressure: 20bar


DWAMV32

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 3...32bar
Adjustable switching differential: 2.5...6bar
Switching differential: no
Max. pressure: 45bar


DWAMV6

Honeywell Maximum pressure monitor of 'special construction' (DA)

Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TUEV-DW-15-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0001 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 1.2...6bar
Adjustable switching differential: 0.4...1.5bar
Switching differential: no
Max. pressure: 10bar


DWR06

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: no
Switching differential: 0.04bar
Max. pressure: 6bar


DWR06-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Adjustable switching differential: 0.08...0.5bar
Switching differential: no
Max. pressure: 6bar


DWR06-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 0.1...0.6bar
Max. pressure: 6bar


DWR06-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 0.1...0.6bar
Max. pressure: 6bar


DWR06-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.04bar
Max. pressure: 6bar


DWR06-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.04bar
Max. pressure: 6bar


DWR06-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.04bar
Max. pressure: 6bar


DWR1

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: no
Switching differential: 0.06bar
Max. pressure: 6bar


DWR1-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Adjustable switching differential: 0.15...0.6bar
Switching differential: no
Max. pressure: 6bar


DWR1-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 0.2...1.6bar
Max. pressure: 6bar


DWR1-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 0.2...1.6bar
Max. pressure: 6bar


DWR1-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.06bar
Max. pressure: 6bar


DWR1-575

Honeywell Minimum pressure monitor (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-575)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Switching contacts: silver alloy Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.06bar
Max. pressure: 6bar


DWR1-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.06bar
Max. pressure: 6bar


DWR1-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.06bar
Max. pressure: 6bar


DWR16

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: no
Switching differential: 0.5bar
Max. pressure: 25bar


DWR16-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 3...16bar
Adjustable switching differential: 0.75...3.15bar
Switching differential: no
Max. pressure: 25bar


DWR16-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 3...16bar
Max. pressure: 25bar


DWR16-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 3...16bar
Max. pressure: 25bar


DWR16-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.5bar
Max. pressure: 25bar


DWR16-575

Honeywell Minimum pressure monitor (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-575)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Switching contacts: silver alloy Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.5bar
Max. pressure: 25bar


DWR16-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.5bar
Max. pressure: 25bar


DWR16-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.5bar
Max. pressure: 25bar


DWR25

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 4...25bar
Adjustable switching differential: no
Switching differential: 1bar
Max. pressure: 63bar


DWR25-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 4...25bar
Adjustable switching differential: 1.3...6bar
Switching differential: no
Max. pressure: 63bar


DWR25-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 4...25bar
Max. pressure: 63bar


DWR25-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 4...25bar
Max. pressure: 63bar


DWR25-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 4...25bar
Switching differential: 1bar
Max. pressure: 63bar


DWR25-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 4...25bar
Switching differential: 1bar
Max. pressure: 63bar


DWR25-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 4...25bar
Switching differential: 1bar
Max. pressure: 63bar


DWR3

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: no
Switching differential: 0.1bar
Max. pressure: 16bar


DWR3-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: 0.17...1.2bar
Switching differential: no
Max. pressure: 16bar


DWR3-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 0.2...2.5bar
Max. pressure: 16bar


DWR3-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 0.2...2.5bar
Max. pressure: 16bar


DWR3-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Switching differential: 0.1bar
Max. pressure: 16bar


DWR3-575

Honeywell Minimum pressure monitor (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-575)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Switching contacts: silver alloy Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Switching differential: 0.1bar
Max. pressure: 16bar


DWR3-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Switching differential: 0.1bar
Max. pressure: 16bar


DWR3-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Switching differential: 0.1bar
Max. pressure: 16bar


DWR40

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 8...40bar
Adjustable switching differential: no
Switching differential: 1.3bar
Max. pressure: 63bar


DWR40-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 8...40bar
Adjustable switching differential: 2.3...6.6bar
Switching differential: no
Max. pressure: 63bar


DWR40-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 8...40bar
Max. pressure: 63bar


DWR40-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 8...40bar
Max. pressure: 63bar


DWR40-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 8...40bar
Switching differential: 1.3bar
Max. pressure: 63bar


DWR40-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 8...40bar
Switching differential: 1.3bar
Max. pressure: 63bar


DWR6

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: no
Switching differential: 0.2bar
Max. pressure: 16bar


DWR6-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: 0.3...1.4bar
Switching differential: no
Max. pressure: 16bar


DWR6-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 0.5...6bar
Max. pressure: 16bar


DWR6-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 0.5...6bar
Max. pressure: 16bar


DWR6-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 16bar


DWR6-575

Honeywell Minimum pressure monitor (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-575)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Switching contacts: silver alloy Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 16bar


DWR6-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 16bar


DWR6-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 16bar


DWR625

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: no
Switching differential: 0.25bar
Max. pressure: 25bar


DWR625-203

Honeywell Pressure monitor for hot water, steam, gas, fuel (DWR)

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2

Adjustable pressure hysteresis
Pressure adjustment range: 0.5...6bar
Adjustable switching differential: 0.4...2.5bar
Switching differential: no
Max. pressure: 25bar


DWR625-205

Honeywell Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: maximum press./button


Pressure adjustment range: 0.5...6bar
Max. pressure: 25bar


DWR625-206

Honeywell Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83
CE-0085CL0343 according DIN EN 1854, Issue 7.2006
01 202 931-B-11-0003 according to Directive 97/23 EG
SIL2 according IEC 61508-2
Pressure interlock/Reset: minimum press./button


Pressure adjustment range: 0.5...6bar
Max. pressure: 25bar


DWR625-574

Honeywell Minimum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-574)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 65oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.25bar
Max. pressure: 25bar


DWR625-575

Honeywell Minimum pressure monitor (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-575)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Switching contacts: silver alloy Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.25bar
Max. pressure: 25bar


DWR625-576

Honeywell Maximum pressure monitor (Ex-i) for hot water, steam, gas, fuel (DWR...-576)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 MikroH
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.25bar
Max. pressure: 25bar


DWR625-577

Honeywell Maximum pressure limiter (Ex-i) with internal interlock for hot water, steam, gas, fuel (DWR...-577)

In many aspects, safety engineered pressure limiters offer a higher degree of safety compared with normal pressure switches and are therefore especially suitable for chemical process engineering and thermal installations in which safety is an especially critical factor in pressure monitoring. Pressure switches can also be used in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. The isolating amplifier is also responsible for monitoring lines for short circuit and line break and therefore offers an additional safety advantage even in non Ex-zones. For Ex-applications, the isolating amplifier must be installed outside the Ex-zone. The lines between the isolating amplifier and the pressure switch are monitored for short circuit and line break. Explosion protection code: Ex II 1/2G Ex ia IIC T6 Ga/Gb, Ex II 1/2D Ex ia IIIC T80 oC
Intrinsically Safety: The equipment employed in explosion relevant areas are components of inherently safe electrical circuits. An electrical circuit is inherently safe if the amount of energy it contains is so small that no spark or other thermal effect can arise. This reliably prevents the ignition of explosive gas mixtures in the proximity of this equipment. In the context of this directive, pressure switches and thermostats containing no switching components with energy storage effects are referred to as "simple electrical equipment."
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12. Aluminium housing coated with resistant plastic
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...60C
Media temp. limit: 60 oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: Power supply circuit: Ui = 14 V DC Ri = 1500 Ohm Ci = 1 nF Li = 100 Mikro H
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.25bar
Max. pressure: 25bar


EEM-CONVERT

Honeywell S0-Pulse counter, 4 inputs, EEM-CONVERT

The S0-Pulse counter with Modbus Interface allows to count pulse from Meters (Electrical, Gas, Water, etc.) with S0-Pulse (without intelligent Interface such Modbus), memorize this and send to the BMS System over one Modbus RTU Interface.
230 Vac, 50 Hz power supply
Up to 99 S0-Modbus Modules on the same bus
4 S0 pulse inputs (S01+...S04+) per S0-Modbus Module
Up to 396 S0 devices on the same Modbus
The inputs comply with the S0 standard EN62053-31
Integrated RS-485 termination resistor
LED for bus activity indication
Interface: ModBus RTU


EEM230-D-M

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: M-Bus
Certificates: no


EEM230-D-M-MID

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: M-Bus
Certificates: MID


EEM230-D-MO

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: ModBus RTU
Certificates: no


EEM230-D-MO-MID

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: ModBus RTU
Certificates: MID


EEM230-D-P

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: pulse
Certificates: no


EEM230-D-P-MID

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: pulse
Certificates: MID


EEM230-E-P

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, Economic, EEM230-E

Energy meter with LCD display and integrated S0 interface. The S0 interface is a hardware interface for the transmission of measured values in building automation.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
7-digit LC-Display
Lead seal possible with cap as accessory
Precision class 1 according to IEC62053-21
S0 output according to IEC62053-31
Clear fault indication
Interface: pulse


EEM230-SEALCAP

Honeywell Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D


20 sealcaps (for 10 energy meters)



EEM400-D-M

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: no


EEM400-D-M-MID

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: MID


EEM400-D-MO

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: no


EEM400-D-MO-MID

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: MID


EEM400-D-P

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: no


EEM400-D-P-MID

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: MID


EEM400-SEALCAP

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D


20 sealcaps (for 5 energy meters)



EEM400C-D-M

Honeywell Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: no


EEM400C-D-M-MID

Honeywell Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: MID


EEM400C-D-MO

Honeywell Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: no


EEM400C-D-MO-MID

Honeywell Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: MID


EEM400C-D-P

Honeywell Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: no


EEM400C-D-P-MID

Honeywell Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: MID


ENC-Slot-MI1-MI3

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: Required external cover to fix option boards on HVAC232/402 frame size 1..3 for devices up to 5,5 kW
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


ENC-Slot-MI4-MI5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: Required internal moulding to fix option boards on HVAC232/402 frame size 4..5 for devices bigger than 5,5 kW
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


ETR2

Honeywell Transformer wall mounting

Transformer to be mounted outside of cabinets, built in closed housing.
Protection class: IP54
Input voltage: 220 V, 50/60Hz
Output voltage: 24Vac
Power 45 VA
With mains cable 1,5 m and mains plug.
With low voltage cable 3 m, without plug.


EVA1-DANFOSS

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Adapters

Danfoss-RA adapter



EX-DCM4016

Honeywell Pressure switch (Ex-d) for liquid, gas (Ex-DCM)

Pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 0.001...0.016bar
Switching differential: 0.002bar
Max. pressure: 1bar
Sensing element material: Perbunan + 1.4301


EX-DCM4025

Honeywell Pressure switch (Ex-d) for liquid, gas (Ex-DCM)

Pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 0.004...0.025bar
Switching differential: 0.002bar
Max. pressure: 1bar
Sensing element material: Perbunan + 1.4301


EX-DDCM014

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -0.1...0.4bar
Switching differential: 0.15bar
Max. pressure: 15bar
Sensing element material: 1.4305 + 1.4571


EX-DDCM1

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.13bar
Max. pressure: 15bar
Sensing element material: 1.4305 + 1.4571


EX-DDCM16

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 3...16bar
Switching differential: 0.6bar
Max. pressure: 25bar
Sensing element material: 1.4305 + 1.4571


EX-DDCM1602

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 0.02...0.16bar
Switching differential: 0.02bar
Max. pressure: 3bar
Sensing element material: Perbunan + Aluminium


EX-DDCM252

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 0.004...0.025bar
Switching differential: 0.002bar
Max. pressure: 0.5bar
Sensing element material: Perbunan + Aluminium


EX-DDCM4

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 1...4bar
Switching differential: 0.2bar
Max. pressure: 25bar
Sensing element material: 1.4305 + 1.4571


EX-DDCM6

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 15bar
Sensing element material: 1.4305 + 1.4571


EX-DDCM6002

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.035bar
Max. pressure: 3bar
Sensing element material: Perbunan + Aluminium


EX-DDCM662

Honeywell Differential pressure switch (Ex-d) for liquid, gas (Ex-DDCM)

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: 0.01...0.06bar
Switching differential: 0.015bar
Max. pressure: 1.5bar
Sensing element material: Perbunan + Aluminium


EX-DGM506

Honeywell Pressure monitor (Ex-d) for burnable gas (Ex-DGM)

For overpressure monitoring in Ex-applications of fuel gases. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
IBExU12ATEX1040 according ATEX 2014/34/EU
SIL2 according IEC 61508-2
Max. pressure: 5bar


Pressure adjustment range: 15...60mbar
Switching differential: 10mbar


EX-DGM516

Honeywell Pressure monitor (Ex-d) for burnable gas (Ex-DGM)

For overpressure monitoring in Ex-applications of fuel gases. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
IBExU12ATEX1040 according ATEX 2014/34/EU
SIL2 according IEC 61508-2
Max. pressure: 5bar


Pressure adjustment range: 40...160mbar
Switching differential: 12mbar


EX-DGM525

Honeywell Pressure monitor (Ex-d) for burnable gas (Ex-DGM)

For overpressure monitoring in Ex-applications of fuel gases. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
IBExU12ATEX1040 according ATEX 2014/34/EU
SIL2 according IEC 61508-2
Max. pressure: 5bar


Pressure adjustment range: 100...250mbar
Switching differential: 20mbar


EX-DNM10

Honeywell Pressure switch (Ex-d) for liquid, gas (Ex-DCM)

Pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 1...10bar
Switching differential: 0.3bar
Max. pressure: 16bar
Sensing element material: 1.4104 + 1.4571


EX-DNM63

Honeywell Pressure switch (Ex-d) for liquid, gas (Ex-DCM)

Pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For overpressure monitoring of non-aggressive liquids and gaseous media.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077

Fixed pressure hysteresis
Pressure adjustment range: 16...63bar
Switching differential: 1bar
Max. pressure: 130bar
Sensing element material: 1.4104 + 1.4571


EX-DNS025

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.04...0.25bar
Switching differential: 0.03bar
Max. pressure: 6bar


EX-DNS06

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.04bar
Max. pressure: 6bar


EX-DNS1

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.06bar
Max. pressure: 6bar


EX-DNS10

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 1...10bar
Switching differential: 0.3bar
Max. pressure: 16bar


EX-DNS16

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.5bar
Max. pressure: 25bar


EX-DNS3

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Switching differential: 0.1bar
Max. pressure: 16bar


EX-DNS6

Honeywell Pressure switch (Ex-d) for aggressive liquid, gas (Ex-DNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-2

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.15bar
Max. pressure: 16bar


EX-DWR06

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.1...0.6bar
Switching differential: 0.04bar
Max. pressure: 6bar


EX-DWR1

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...1.6bar
Switching differential: 0.06bar
Max. pressure: 6bar


EX-DWR16

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 3...16bar
Switching differential: 0.5bar
Max. pressure: 25bar


EX-DWR25

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 4...25bar
Switching differential: 1bar
Max. pressure: 63bar


EX-DWR3

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Switching differential: 0.1bar
Max. pressure: 16bar


EX-DWR40

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 8...40bar
Switching differential: 1.3bar
Max. pressure: 63bar


EX-DWR6

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.2bar
Max. pressure: 16bar


EX-DWR625

Honeywell Pressure monitor (Ex-d) for hot water, steam, gas, fuel (Ex-DWR)

FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching pressure ranges and thus also the scale divisions on the switching devices are to be understood as the difference in pressure between the releant atmospheric pressure and the set switching pressure. The "zero" reference point on the scale of the unit corresponds to the relevant atmospheric pressure. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Flame proof enclosure Switch components and other electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -20...60C
Media temp. limit: 60oC. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -20...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008
CE-0085CL0343 according to DIN EN 1854, Issue 07.2006
01 202 931-B-11-0003 according Directive 97/23 EC
IBExU12ATEX1040 according ATEX 2014/34/EU
IECEx IBE 14.0077
SIL2 according IEC 61508-02

Fixed pressure hysteresis
Pressure adjustment range: 0.5...6bar
Switching differential: 0.25bar
Max. pressure: 25bar


EX-TAM022

Honeywell Capillary tube thermostat (Ex-d) with sensing bulb (Ex-TAM)

The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die-cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Capillary tube length: 1.5m
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: capillary tube thermostat


Temp. setpoint range: -20...20C
Differential fixed: 1.5K
Max. perm. temp. at sensor: 110C


EX-TAM150

Honeywell Capillary tube thermostat (Ex-d) with sensing bulb (Ex-TAM)

The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die-cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Capillary tube length: 1.5m
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: capillary tube thermostat


Temp. setpoint range: 10...50C
Differential fixed: 1.5K
Max. perm. temp. at sensor: 110C


EX-TAM490

Honeywell Capillary tube thermostat (Ex-d) with sensing bulb (Ex-TAM)

The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die-cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Capillary tube length: 1.5m
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: capillary tube thermostat


Temp. setpoint range: 40...90C
Differential fixed: 2K
Max. perm. temp. at sensor: 125C


EX-TAM813

Honeywell Capillary tube thermostat (Ex-d) with sensing bulb (Ex-TAM)

The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die-cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Capillary tube length: 1.5m
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: capillary tube thermostat


Temp. setpoint range: 80...130C
Differential fixed: 2K
Max. perm. temp. at sensor: 150C


EX-TRM022

Honeywell Room thermostat (Ex-d) for industrial permises (Ex-TRM)

Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and relay stations.
Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Including mounting bracket typenumber H1.
Thermostat application: room thermostat
Differential fixed: 1K
Max. perm. temp. at sensor: 70C


Temp. setpoint range: -20...20C


EX-TRM150

Honeywell Room thermostat (Ex-d) for industrial permises (Ex-TRM)

Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and relay stations.
Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Including mounting bracket typenumber H1.
Thermostat application: room thermostat
Differential fixed: 1K
Max. perm. temp. at sensor: 70C


Temp. setpoint range: 10...50C


EX-TRM40

Honeywell Room thermostat (Ex-d) for industrial permises (Ex-TRM)

Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and relay stations.
Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Including mounting bracket typenumber H1.
Thermostat application: room thermostat
Differential fixed: 1K
Max. perm. temp. at sensor: 70C


Temp. setpoint range: 0...40C


EX-TX023

Honeywell Rod thermostat (Ex-d) for vessels (Ex-TX)

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: immersion rod thermostat

Immersion length 135 mm
Temp. setpoint range: -20...30C
Immersion depth: 135mm
Differential fixed: 1.5K
Max. perm. temp. at sensor: 110C


EX-TX150

Honeywell Rod thermostat (Ex-d) for vessels (Ex-TX)

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: immersion rod thermostat

Immersion length 135 mm
Temp. setpoint range: 10...50C
Immersion depth: 135mm
Differential fixed: 1.5K
Max. perm. temp. at sensor: 110C


EX-TX490

Honeywell Rod thermostat (Ex-d) for vessels (Ex-TX)

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: immersion rod thermostat

Immersion length 135 mm
Temp. setpoint range: 40...90C
Immersion depth: 135mm
Differential fixed: 2.5K
Max. perm. temp. at sensor: 125C


EX-TXB023

Honeywell Rod thermostat (Ex-d) for vessels (Ex-TX)

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: immersion rod thermostat

Immersion length 220 mm
Temp. setpoint range: -20...30C
Immersion depth: 220mm
Differential fixed: 1.5K
Max. perm. temp. at sensor: 110C


EX-TXB150

Honeywell Rod thermostat (Ex-d) for vessels (Ex-TX)

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: immersion rod thermostat

Immersion length 220 mm
Temp. setpoint range: 10...50C
Immersion depth: 220mm
Differential fixed: 1.5K
Max. perm. temp. at sensor: 110C


EX-TXB490

Honeywell Rod thermostat (Ex-d) for vessels (Ex-TX)

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: die cast metal GD Al Si 12 to DIN 1725
Ambient temperature: -15...60C
Switch function/capacity: SPDT 250 Vac, 3(2) A
Certificates: SIL 2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Thermostat application: immersion rod thermostat

Immersion length 220 mm
Temp. setpoint range: 40...90C
Immersion depth: 220mm
Differential fixed: 2.5K
Max. perm. temp. at sensor: 125C


EX-VCM095

Honeywell Vacuum switches (Ex-d) liquid, gas (Ex-VCM)

Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For monitoring vacuum of non-aggressive liquids and gaseous media.
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -900...500mbar
Switching differential: 50mbar
Max. pressure: 3bar
Sensing element material: Copper + Brass


EX-VCM101

Honeywell Vacuum switches (Ex-d) liquid, gas (Ex-VCM)

Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For monitoring vacuum of non-aggressive liquids and gaseous media.
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -1000...100mbar
Switching differential: 45mbar
Max. pressure: 3bar
Sensing element material: Copper + Brass


EX-VCM301

Honeywell Vacuum switches (Ex-d) liquid, gas (Ex-VCM)

Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For monitoring vacuum of non-aggressive liquids and gaseous media.
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -250...100mbar
Switching differential: 25mbar
Max. pressure: 1.5bar
Sensing element material: Copper + Brass


EX-VCM4156

Honeywell Vacuum switches (Ex-d) liquid, gas (Ex-VCM)

Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For monitoring vacuum of non-aggressive liquids and gaseous media.
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -15...6mbar
Switching differential: 2mbar
Max. pressure: 1bar
Sensing element material: Perbunan + 1.4301


EX-VNM111

Honeywell Vacuum switches (Ex-d) liquid, gas (Ex-VCM)

Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For monitoring vacuum of non-aggressive liquids and gaseous media.
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -1000...100mbar
Switching differential: 50mbar
Max. pressure: 6bar
Sensing element material: 1.4104 + 1.4571


EX-VNM301

Honeywell Vacuum switches (Ex-d) liquid, gas (Ex-VCM)

Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
For monitoring vacuum of non-aggressive liquids and gaseous media.
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077


Pressure adjustment range: -250...100mbar
Switching differential: 45mbar
Max. pressure: 3bar
Sensing element material: 1.4104 + 1.4571


EX-VNS111

Honeywell Vacuum switch (Ex-d) for aggressive liquid, gas (Ex-VNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: -1000...100mbar
Switching differential: 50mbar
Max. pressure: 6bar


EX-VNS301

Honeywell Vacuum switch (Ex-d) for aggressive liquid, gas (Ex-VNS)

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
Kind of pressure: vacuum, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12.
Media temp.: -15...60C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -15...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive
Certificates: SIL2 according IEC 61508-2
IBExU12ATEX1040 according to ATEX 2014/34/EU
IECEx IBE 14.0077
Sensing element material: 1.4571

Fixed pressure hysteresis
Pressure adjustment range: -250...100mbar
Switching differential: 45mbar
Max. pressure: 3bar


EXCELON

Honeywell CARE software


Software license for EXCELON Lon Analyzer (with protection plug)



FD16-326

Honeywell Maximum pressure limiter (FD)

Maximum pressure limiter for liquid gas systems with safety function, degree of protection Ex-i (only together with isolating switching amplifier).
Kind of pressure: overpressure, relative
Pressure connection: external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 60 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch with resistor combination for circuit- break and short-circuit
Certificates: ID 0000033127 according VdTUEV Memorandum Pressure 100/1, Issue 07.2006 and DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0002 according Directive 97/23/EC
SIL2 according IEC 61508-2
Products only may be used in conjunction with isolating switching amplifier.
Pressure adjustment range: 3...16bar
Max. pressure: 40bar
Sensing element material: 1.4104 + 1.4571


Switching differential: 0.5bar
Pressure interlock/Reset: maximum press./electrical


FD16-327

Honeywell Maximum pressure limiter (FD)

Maximum pressure limiter for liquid gas systems with safety function, degree of protection Ex-i (only together with isolating switching amplifier).
Kind of pressure: overpressure, relative
Pressure connection: external thread G1/2
Electrical connection: terminal connection M16x1,5
Protection class: IP65
Housing material: rugged housing of seawater resistant aluminium die casting GD Al Si 12
Media temp.: -25...60C
Media temp. limit: temperatures up to 60 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...60C
Ambient temp. limit: at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device
Switch function/capacity: SPDT Microswitch with resistor combination for circuit- break and short-circuit
Certificates: ID 0000033127 according VdTUEV Memorandum Pressure 100/1, Issue 07.2006 and DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007
01 202 931-B-11-0002 according Directive 97/23/EC
SIL2 according IEC 61508-2
Products only may be used in conjunction with isolating switching amplifier.
Pressure adjustment range: 3...16bar
Max. pressure: 40bar
Sensing element material: 1.4104 + 1.4571


Switching differential: 2.5bar
Pressure interlock/Reset: maximum press./button


FT6960-18

Honeywell Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary with bulb
Capillary tube length: 1.8m
Mechanical lock/reset: manual


FT6960-30

Honeywell Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 3m
Mechanical lock/reset: manual


FT6960-60

Honeywell Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 6m
Mechanical lock/reset: manual


FT6961-18

Honeywell Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary with bulb
Capillary tube length: 1.8m
Mechanical lock/reset: automatic


FT6961-30

Honeywell Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 3m
Mechanical lock/reset: automatic


FT6961-60

Honeywell Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 6m
Mechanical lock/reset: automatic


FTSE20

Honeywell Two-Stage Frost protection thermostat (FTSE)

Frost protection thermostats are installed on the air side for the purpose of protecting air conditioning units, heat exchangers, radiators, and similar installations against damages due to frost or freezing. With the FTSE Electonic Frost Protection Thermostat, Honeywell FEMA has expanded its line of electromechanical products with an electronic device.
Ambient temperature: 15...15C
Switch function/capacity: SPDT 250 Vac Microswitch / 8A
Protection Class: IP42
Setting Range: 1 ... 10 Degrees C
Electrical Connection: Terminals with tension clamp
Power Supplay: 24 V AC, +10/-20%
Analog Input: 0-10V
Analog Output: 0-10V
Temperature Output: 0-10V @ 0-10 degrees C


Capillary tube length: 2m


FTSE60

Honeywell Two-Stage Frost protection thermostat (FTSE)

Frost protection thermostats are installed on the air side for the purpose of protecting air conditioning units, heat exchangers, radiators, and similar installations against damages due to frost or freezing. With the FTSE Electonic Frost Protection Thermostat, Honeywell FEMA has expanded its line of electromechanical products with an electronic device.
Ambient temperature: 15...15C
Switch function/capacity: SPDT 250 Vac Microswitch / 8A
Protection Class: IP42
Setting Range: 1 ... 10 Degrees C
Electrical Connection: Terminals with tension clamp
Power Supplay: 24 V AC, +10/-20%
Analog Input: 0-10V
Analog Output: 0-10V
Temperature Output: 0-10V @ 0-10 degrees C


Capillary tube length: 6m


G12-100

Honeywell Electronic thermostats (SmartTemp)
Accessories / Immersion Tubes

G1/2, cylindrical



G12-200

Honeywell Immersion probe temperature sensor, stainless steel (P)
Accessories,suitable only for P100-XXX

Immersion tube, G1/2, immersion length 200 mm



G12-250

Honeywell Electronic thermostats (SmartTemp)
Accessories / Immersion Tubes

G1/2, cylindrical



GB12

Honeywell Solenoid valves for gaseous and liquid medium (GB)

The 2/2-way valves of the GB-series are suitable for general applications and are not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel
Media temp.: -10...90C
Ambient temperature: -10...55C
Operating mode: normally closed
Power supply: 230V 45..60Hz
Working range: 0...16bar

Brass valve body, Sealings: Perbunan
DN size: 12mm
Kvs value: 2.8
Connections: G1/2


GB12VA

Honeywell Solenoid valves for gaseous and liquid medium (GB)

The 2/2-way valves of the GB-series are suitable for general applications and are not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel
Media temp.: -10...90C
Ambient temperature: -10...55C
Operating mode: normally closed
Power supply: 230V 45..60Hz
Working range: 0...16bar

Stainless steel 1.4410 valve body, Sealings: Viton(R)
DN size: 12mm
Kvs value: 2.8
Connections: G1/2


GB20

Honeywell Solenoid valves for gaseous and liquid medium (GB)

The 2/2-way valves of the GB-series are suitable for general applications and are not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel
Media temp.: -10...90C
Ambient temperature: -10...55C
Operating mode: normally closed
Power supply: 230V 45..60Hz
Working range: 0...16bar

Brass valve body, Sealings: Perbunan
DN size: 20mm
Kvs value: 5
Connections: G3/4


GB20VA

Honeywell Solenoid valves for gaseous and liquid medium (GB)

The 2/2-way valves of the GB-series are suitable for general applications and are not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel
Media temp.: -10...90C
Ambient temperature: -10...55C
Operating mode: normally closed
Power supply: 230V 45..60Hz
Working range: 0...16bar

Stainless steel 1.4410 valve body, Sealings: Viton(R)
DN size: 20mm
Kvs value: 5
Connections: G3/4


GB25

Honeywell Solenoid valves for gaseous and liquid medium (GB)

The 2/2-way valves of the GB-series are suitable for general applications and are not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel
Media temp.: -10...90C
Ambient temperature: -10...55C
Operating mode: normally closed
Power supply: 230V 45..60Hz
Working range: 0...16bar

Brass valve body, Sealings: Perbunan
DN size: 25mm
Kvs value: 10
Connections: G1


GB25VA

Honeywell Solenoid valves for gaseous and liquid medium (GB)

The 2/2-way valves of the GB-series are suitable for general applications and are not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel
Media temp.: -10...90C
Ambient temperature: -10...55C
Operating mode: normally closed
Power supply: 230V 45..60Hz
Working range: 0...16bar

Stainless steel 1.4410 valve body, Sealings: Viton(R)
DN size: 25mm
Kvs value: 10
Connections: G1


GD250W4NB

Honeywell CO Gas detector GD250

GD250W4NB is IAQ (Indoor Air Quality) sensor, which has been designed to detect carbon monoxide gas in the air. This model has high accuracy at low concentration, so it is optimized for parking lot, tunnel and under ground places. Also, the advantage of this model is compact size and easy installation.
Specification
Sensor type: Electrochemical
Detect range: 0-250 ppm
Power supply: 24 Vac/dc
Output signal: 2-10 Vdc (default) or 4-20 mA (selectable by jumper)
Coverage area: 465-900 m2
Response time: Within 30 seconds to 90% of final value


GK13

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Screwed version, material: brass
DN size: 13mm
Kvs value: 3.7
Connections: G1/2


GK20

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Screwed version, material: brass
DN size: 20mm
Kvs value: 5
Connections: G3/4


GK25

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Screwed version, material: brass
DN size: 25mm
Kvs value: 10
Connections: G1


GK25F

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Flanged version, material: cast iron GG25
DN size: 25mm
Kvs value: 10
Connections: flange


GK32

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Screwed version, material: brass
DN size: 32mm
Kvs value: 16
Connections: G1 1/4


GK32F

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Flanged version, material: cast iron GG25
DN size: 32mm
Kvs value: 16
Connections: flange


GK40

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Screwed version, material: brass
DN size: 40mm
Kvs value: 16
Connections: G1 1/2


GK40F

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Flanged version, material: cast iron GG25
DN size: 40mm
Kvs value: 16
Connections: flange


GK50

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Screwed version, material: brass
DN size: 50mm
Kvs value: 36
Connections: G2


GK50F

Honeywell Solenoid valves for media up to 180 degree (GK)

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: PTFE and graphite
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar

Flanged version, material: cast iron GG25
DN size: 50mm
Kvs value: 36
Connections: flange


H6045A1002

Honeywell Room and air duct humidistats (H)

The H6045A1002 single-stage duct hygrostat and the H6120A1000 single-stage room hygrostat are designed for monitoring relative humidity in air conditioning systems and climatic chambers and for controlling air humidifiers and dehumidifiers in indoor swimming pool buildings. Further applications include air humidity regulation in food storage premises, the textile and paper industries, printing works, the optical and chemical industries, greenhouses, hospitals and wherever relative air humidity levels need to be measured, controlled and monitored.
Maximum air flow speed for ducts: 8 m/s.
R.H. setpoint range: 35...100%rh
(De) Humidification application: D + H

Duct humidistat H6045
R.H. hysteresis switching point: 5%rh
Ambient temperature: -10...65C
Mounting place: air duct
Immersion depth: 222mm
Switch function/capacity: SPDT 250Vac/15A (8A)
Protection class: IP65


H6120A1000

Honeywell Room and air duct humidistats (H)

The H6045A1002 single-stage duct hygrostat and the H6120A1000 single-stage room hygrostat are designed for monitoring relative humidity in air conditioning systems and climatic chambers and for controlling air humidifiers and dehumidifiers in indoor swimming pool buildings. Further applications include air humidity regulation in food storage premises, the textile and paper industries, printing works, the optical and chemical industries, greenhouses, hospitals and wherever relative air humidity levels need to be measured, controlled and monitored.
Maximum air flow speed for ducts: 8 m/s.
R.H. setpoint range: 35...100%rh
(De) Humidification application: D + H

Room humidistat H6120
R.H. hysteresis switching point: 4%rh
Ambient temperature: 0...60C
Mounting place: internal wall
Immersion depth: no
Switch function/capacity: SPDT 230Vac /5A (0,2A)
Protection class: IP30


H615A2015

Honeywell Room humidistat, low voltage

Low voltage humidistat for humidity control of rooms.
Switch function/capacity: SPDT 48 Vac, 6 A
With internal setpoint adjustment limiter. Including mounting base/ring.
R.H. hysteresis switching point: 5%rh
Ambient temperature: 10...50C
R.H. sensing element: nylon
(De) Humidification application: D + H
Mounting place: internal wall


R.H. setpoint range: 30...80%rh


H615A2077

Honeywell Room humidistat, low voltage

Low voltage humidistat for humidity control of rooms.
Switch function/capacity: SPDT 48 Vac, 6 A
With internal setpoint adjustment limiter. Including mounting base/ring.
R.H. hysteresis switching point: 5%rh
Ambient temperature: 10...50C
R.H. sensing element: nylon
(De) Humidification application: D + H
Mounting place: internal wall


R.H. setpoint range: 50...90%rh


H7012A1010

Honeywell Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: no
Output signal: no
Temperature range: no


H7012B1008

Honeywell Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: Pt1000
Output signal: no
Temperature range: 0...50C


H7012B1024

Honeywell Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: NTC20k
Output signal: no
Temperature range: 0...50C


H7012B1030

Honeywell Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: no
Output signal: temp: 0..10V=
Temperature range: 0...50C


H7508B1060

Honeywell Outdoor R.H.- and temperature sensor/transmitter

Protection class: IP34
Relative humidity sensor accuracy class: 3%.
Temperature range: -30...50C
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vacdc
Mounting place: wall outside
Housing (HxWxD): 172mm|132mm|60mm


Temperature element: no
Output signal: temp: 0..10V=
Wiring terminals: 5


H7508B1080

Honeywell Outdoor R.H.- and temperature sensor/transmitter

Protection class: IP34
Relative humidity sensor accuracy class: 3%.
Temperature range: -30...50C
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vacdc
Mounting place: wall outside
Housing (HxWxD): 172mm|132mm|60mm


Temperature element: NTC20k
Output signal: no
Wiring terminals: 6


HCA1VEL

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Adapters

Mounting adapter for Velta -Compact Manifold



HCD6003

Honeywell Pressure switch for gas (HCD)

For monitoring pressure of neutral and non-aggressive gases.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...60C
Ambient temperature: -15...60C
Switch function/capacity: SPDT Microswitch 240 Vac; capacity 2 A inductive, 10 A resistive
Certificates: E 3085/2 according gas appliance directive 90/396/EEC and pr EN 1854, issue 1995
Sensing element material: Aluminium + Silicon


Pressure adjustment range: 0.2...3mbar
Max. pressure: 100mbar


HCD6010

Honeywell Pressure switch for gas (HCD)

For monitoring pressure of neutral and non-aggressive gases.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...60C
Ambient temperature: -15...60C
Switch function/capacity: SPDT Microswitch 240 Vac; capacity 2 A inductive, 10 A resistive
Certificates: E 3085/2 according gas appliance directive 90/396/EEC and pr EN 1854, issue 1995
Sensing element material: Aluminium + Silicon


Pressure adjustment range: 1...10mbar
Max. pressure: 100mbar


HCD6050

Honeywell Pressure switch for gas (HCD)

For monitoring pressure of neutral and non-aggressive gases.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...60C
Ambient temperature: -15...60C
Switch function/capacity: SPDT Microswitch 240 Vac; capacity 2 A inductive, 10 A resistive
Certificates: E 3085/2 according gas appliance directive 90/396/EEC and pr EN 1854, issue 1995
Sensing element material: Aluminium + Silicon


Pressure adjustment range: 5...50mbar
Max. pressure: 200mbar


HCD6150

Honeywell Pressure switch for gas (HCD)

For monitoring pressure of neutral and non-aggressive gases.
Kind of pressure: differential pressure, relative
Pressure connection: internal thread G1/4
Electrical connection: PG13,5
Protection class: IP40
Housing material: aluminium die casting
Media temp.: -15...60C
Ambient temperature: -15...60C
Switch function/capacity: SPDT Microswitch 240 Vac; capacity 2 A inductive, 10 A resistive
Certificates: E 3085/2 according gas appliance directive 90/396/EEC and pr EN 1854, issue 1995
Sensing element material: Aluminium + Silicon


Pressure adjustment range: 15...150mbar
Max. pressure: 300mbar


HE25

Honeywell Three-way rotary valve PN10
H-extensions

H-extension DN25



HE32

Honeywell Three-way rotary valve PN10
H-extensions

H-extension DN32



HGK3

Honeywell Air duct humidistat

Line voltage immersion humidistat for air ducts or industrial areas.
Switch function/capacity: SPDT 230 Vac, 15 A
R.H. setpoint range: 35...100%rh
R.H. hysteresis switching point: 4%rh
Ambient temperature: -30...60C
R.H. sensing element: plastic tissue
(De) Humidification application: D + H
Mounting place: air duct


HP971A1024

Honeywell Pneumatic room humidity sensor, HP971

One- or two-pipe direct-acting humidity sensor used with RP908/RP920 controllers to provide proportional control of pneumatic valve and damper actuators in systems requiring humidification or dehumidification control.
Max. safe air pressure: 172kPa
Max. media temperature: 52C
Supply air pressure: 124kPa
Pressure output: 21...103kPa
Air connection: 1/4 " tubing
Mounting: wall
Action: direct acting
R.H. range: 15...85%rh


HSS-DPS

Honeywell Dew-point switch

This early-warning dew-point switch is designed for use in monitoring cooling water pipes or chilled surfaces in order to determine if temperatures are approaching the dewpoint. It is suitable for mounting on flat and round surfaces. The switch measures the relative humidity prevailing directly at the chilled surface and can thus be used to:
regulating cooling performance
switching cooling systems ON and OFF
signalling if the temperature is approaching the dew-point
Status indication with LED, showing condensation danger
Switching point at 90 %rh, hysteresis 5 %rh
Ambient temperature: 0...50C
Protection class: IP40
Mounting: wall, duct or pipe (max. 50 mm)
Power supply: 24Vacdc
Switch function/capacity: potential free changeover contact; max. 24 Vac/dc, 1 A
Wiring connection: 5-pole push-in terminals, max. 1,5mm2


HVAC-DOOR-KIT

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: SmartDrive HVAC door installation set for display panel, 3m cable
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 4 (HVAC400-1P1..HVAC400-5P5)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 5 (HVAC400-7P5..HVAC400-15P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-6

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 6 (HVAC400-18P..HVAC400-30P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-7

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 7 (HVAC400-37P..HVAC400-55P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-8

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 8 (HVAC400-75P..HVAC400-110P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-9

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 9 (HVAC400-132P..HVAC400-160P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-SUP-FR08

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, power supply, frame size 8, HVAC400-75Px - HVAC400-110x
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-SUP-FR09

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, power supply, frame size 9, HVAC400-132x - HVAC400-160x
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-HMI-A

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive HVAC display panels
Product description: SmartDrive HVAC advanced commissioning display/keypad with parameter copy function
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-IP54FAN-FR04

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, Internal fan, frame size 4, HVAC400-1P1x - HVAC400-5P5x
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-IP54FAN-FR05

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, Internal fan, frame size 5, HVAC400-7P5x - HVAC400-15Px
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-IP54FAN-FR06

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, Internal fan, frame size 6, HVAC400-18Px - HVAC400-55Px
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-IP54FAN-FR08

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, Internal fan, frame size 8, HVAC400-75Px - HVAC400-110x
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-IP54FAN-FR09

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC400 Cooling Fans
Product description: HVAC400, Internal fan, frame size 9, HVAC400-132x - HVAC400-160x
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-TERM-KIT

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Control Spares
Product description: Kit of terminal for HVAC400x drives
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC03C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 1.1kW
Low overload Icont: 3.3A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A


HVAC04C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 1.5kW
Low overload Icont: 4.3A
High overload (for Machines): 1.1kW
High overload Icont: 3.3A


HVAC05C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 2.2kW
Low overload Icont: 5.6A
High overload (for Machines): 1.5kW
High overload Icont: 4.3A


HVAC07C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 3kW
Low overload Icont: 7.6A
High overload (for Machines): 2.2kW
High overload Icont: 5.6A


HVAC09C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7.6A


HVAC12C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A


HVAC16C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A


HVAC232-1P1-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

230V series
Protection class: IP20
Voltage: 230V
1 phase input: yes
3 phases input: no
Power: 1.1kW
Low overload Icont: 4.8A
Size: 2


HVAC232-1P5-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

230V series
Protection class: IP20
Voltage: 230V
1 phase input: yes
3 phases input: no
Power: 1.5kW
Low overload Icont: 7A
Size: 2


HVAC232-2P2-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

230V series
Protection class: IP20
Voltage: 230V
1 phase input: yes
3 phases input: no
Power: 2.2kW
Low overload Icont: 9.6A
Size: 3


HVAC232-P37-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

230V series
Protection class: IP20
Voltage: 230V
1 phase input: yes
3 phases input: no
Power: 0.37kW
Low overload Icont: 2.4A
Size: 1


HVAC232-P55-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

230V series
Protection class: IP20
Voltage: 230V
1 phase input: yes
3 phases input: no
Power: 0.55kW
Low overload Icont: 2.8A
Size: 1


HVAC232-P75-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

230V series
Protection class: IP20
Voltage: 230V
1 phase input: yes
3 phases input: no
Power: 0.75kW
Low overload Icont: 3.7A
Size: 2


HVAC23C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 11kW
Low overload Icont: 23A
High overload (for Machines): 7.5kW
High overload Icont: 16A


HVAC31C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 23A


HVAC38C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A


HVAC400-110-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 110kW
Low overload Icont: 205A
Size: 8


HVAC400-110-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 110kW
Low overload Icont: 205A
Size: 8


HVAC400-11P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 11kW
Low overload Icont: 23A
Size: 5


HVAC400-11P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 11kW
Low overload Icont: 23A
Size: 5


HVAC400-132-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 132kW
Low overload Icont: 261A
Size: 9


HVAC400-132-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 132kW
Low overload Icont: 261A
Size: 9


HVAC400-15P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 15kW
Low overload Icont: 31A
Size: 5


HVAC400-15P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 15kW
Low overload Icont: 31A
Size: 5


HVAC400-160-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 160kW
Low overload Icont: 310A
Size: 9


HVAC400-160-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 160kW
Low overload Icont: 310A
Size: 9


HVAC400-18P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 18.5kW
Low overload Icont: 38A
Size: 6


HVAC400-18P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 18.5kW
Low overload Icont: 38A
Size: 6


HVAC400-1P1-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 1.1kW
Low overload Icont: 3.4A
Size: 4


HVAC400-1P1-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 1.1kW
Low overload Icont: 3.4A
Size: 4


HVAC400-1P5-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 1.5kW
Low overload Icont: 4.8A
Size: 4


HVAC400-1P5-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 1.5kW
Low overload Icont: 4.8A
Size: 4


HVAC400-22P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 22kW
Low overload Icont: 46A
Size: 6


HVAC400-22P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 22kW
Low overload Icont: 46A
Size: 6


HVAC400-2P2-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 2.2kW
Low overload Icont: 5.6A
Size: 4


HVAC400-2P2-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 2.2kW
Low overload Icont: 5.6A
Size: 4


HVAC400-30P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 30kW
Low overload Icont: 61A
Size: 6


HVAC400-30P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 30kW
Low overload Icont: 61A
Size: 6


HVAC400-37P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 37kW
Low overload Icont: 72A
Size: 7


HVAC400-37P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 37kW
Low overload Icont: 72A
Size: 7


HVAC400-3P0-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 3kW
Low overload Icont: 8A
Size: 4


HVAC400-3P0-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 3kW
Low overload Icont: 8A
Size: 4


HVAC400-45P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 45kW
Low overload Icont: 87A
Size: 7


HVAC400-45P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 45kW
Low overload Icont: 87A
Size: 7


HVAC400-4P0-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 4kW
Low overload Icont: 9.6A
Size: 4


HVAC400-4P0-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 4kW
Low overload Icont: 9.6A
Size: 4


HVAC400-55P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 55kW
Low overload Icont: 105A
Size: 7


HVAC400-55P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 55kW
Low overload Icont: 105A
Size: 7


HVAC400-5P5-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 5.5kW
Low overload Icont: 12A
Size: 4


HVAC400-5P5-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 5.5kW
Low overload Icont: 12A
Size: 4


HVAC400-75P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 75kW
Low overload Icont: 140A
Size: 8


HVAC400-75P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 75kW
Low overload Icont: 140A
Size: 8


HVAC400-7P5-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 7.5kW
Low overload Icont: 16A
Size: 5


HVAC400-7P5-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 7.5kW
Low overload Icont: 16A
Size: 5


HVAC400-90P-21A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Power: 90kW
Low overload Icont: 170A
Size: 8


HVAC400-90P-54A

Honeywell Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Power: 90kW
Low overload Icont: 170A
Size: 8


HVAC402-11P-21

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP21
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 11kW
Low overload Icont: 23A
Size: 4


HVAC402-15P-21

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP21
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 15kW
Low overload Icont: 31A
Size: 5


HVAC402-18P-21

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP21
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 18.5kW
Low overload Icont: 38A
Size: 5


HVAC402-1P1-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 1.1kW
Low overload Icont: 3.3A
Size: 2


HVAC402-1P5-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 1.5kW
Low overload Icont: 4.3A
Size: 2


HVAC402-2P2-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 2.2kW
Low overload Icont: 5.6A
Size: 2


HVAC402-3P0-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 3kW
Low overload Icont: 7.6A
Size: 3


HVAC402-4P0-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 4kW
Low overload Icont: 9A
Size: 3


HVAC402-5P5-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 5.5kW
Low overload Icont: 12A
Size: 3


HVAC402-7P5-21

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP21
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 7.5kW
Low overload Icont: 16A
Size: 4


HVAC402-FAN-FR4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 Cooling Fans
Product description: HVAC402, main fan, size 4, HVAC402-7P5-21 - HVAC402-11P-21
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


HVAC402-FAN-FR5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 Cooling Fans
Product description: HVAC402, main fan, size 5, HVAC402-15P-21 - HVAC402-18P-21
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


HVAC402-P55-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 0.55kW
Low overload Icont: 1.9A
Size: 1


HVAC402-P75-20

Honeywell Inverters 0,37..18,5kW, IP20/IP21, HVAC232/402

Variable frequency drives for induction and permanent magnet motors. Compliant with EMC and LVD. HVAC232 and HVAC402 are compact in size and flexible in application with one free slot for an option board. Easy to operate and commissioning with an embedded wizard.
Torque characteristics can be adjusted to square for pumps and fans or to constant for machines in industrial or process operation.
Features: Start up wizard
Embedded soft-filling-and sleep function
Configurable inputs and outputs: 2 analog inputs (voltage or current), 6 digital inputs, 3 digital outputs (2 relays, 1 open collector), 1 analog output (mA)
Series: HVAC232/402
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
Safety: EN61800-5, CE

400V series
Protection class: IP20
Voltage: 400V
1 phase input: no
3 phases input: yes
Power: 0.75kW
Low overload Icont: 2.4A
Size: 1


HVAC46C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 22kW
Low overload Icont: 46A
High overload (for Machines): 18.5kW
High overload Icont: 38A


HVAC61C5

Honeywell Inverters 1,1..30kW, IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://hwll.co/inverter
1 phase input: no
3 phases input: yes
Protection class: IP54

IP54
Power: 30kW
Low overload Icont: 61A
High overload (for Machines): 22kW
High overload Icont: 46A


HVACDOORKIT

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: HVAC232/402 door installation set including 2m cable and display
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


IF-LON2

Honeywell High performance external LON-USB interface Adapter IF-LON2

Connects a Lon-Bus to the USB interface of one of the following devices: EAGLE, EAGLEHAWK or CLIF-CBUSLC
Product description: LON network interface for use with EAGLE, EAGLEHAWK or CLIF-CBUSLC


IRA-AD

Honeywell Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A
Accessories

Adapter for Danfoss RA2000



IRM-RLC

Honeywell Room Controller ComfortPoint Open
Cover

Terminal cover IP30 for Large housing (10 pieces)



IRM-RSC

Honeywell Room Controller ComfortPoint Open
Cover

Terminal cover IP30 for Small housing (10 pieces)



K430D

Honeywell Accessories for Pressure Switches / Transmitters
Syphons

Syphon for high temperature, steel, circular



K480D

Honeywell Accessories for Pressure Switches / Transmitters
Syphons

Syphon for high temperature, stainless steel, circular



KA10

Honeywell Isolating relay

Relay with inbuilt transformer, and waterproof housing.
Switch function/capacity: SPDT contact, maximum load 4A/250Vac
Model: Power supply 230V; 50Hz; control connection 24 V
Protection class: IP40


KSL230

Honeywell Electronic flow switches for air, compact version (KSL)

These compact flow monitors reliably measure air flow in air ducts and detect any falling below a predefined switching point. The sensitivity and hence the switching point can be set very precisely with a potentiometer. The switching state is shown by a yellow LED. The sensor tip must be completely immersed in the medium. Signal evaluation and the switching process take place within the unit itself so that no additional space is required inside the switch cabinet.
Protection class: IP65
Switch function/capacity: SPDT, capacity 250 Vac, 10(2) A
LED's available for indication of power supply and switch status.
Immersion depth: 115mm
Setpoint range: 0,1..30 m/s
Max. media temperature: 80C
Max. pressure: 10bar

Process connection PG7 + mounting flange
Power supply: 230Vac


KSL24

Honeywell Electronic flow switches for air, compact version (KSL)

These compact flow monitors reliably measure air flow in air ducts and detect any falling below a predefined switching point. The sensitivity and hence the switching point can be set very precisely with a potentiometer. The switching state is shown by a yellow LED. The sensor tip must be completely immersed in the medium. Signal evaluation and the switching process take place within the unit itself so that no additional space is required inside the switch cabinet.
Protection class: IP65
Switch function/capacity: SPDT, capacity 250 Vac, 10(2) A
LED's available for indication of power supply and switch status.
Immersion depth: 115mm
Setpoint range: 0,1..30 m/s
Max. media temperature: 80C
Max. pressure: 10bar

Process connection PG7 + mounting flange
Power supply: 24Vac


KSW230

Honeywell Electronic flow switches for liquid, compact version (KSW)

The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.
Protection class: IP65
Switch function/capacity: SPDT, capacity 250 Vac, 10(2) A
LED's available for indication of power supply and switch status.
Immersion depth: 20mm
Media: liquid and air
Setpoint range: 0,05..3 m/s
Max. media temperature: 80C
Max. pressure: 30bar

Process connection G1/2"
Power supply: 230Vac


KSW24

Honeywell Electronic flow switches for liquid, compact version (KSW)

The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.
Protection class: IP65
Switch function/capacity: SPDT, capacity 250 Vac, 10(2) A
LED's available for indication of power supply and switch status.
Immersion depth: 20mm
Media: liquid and air
Setpoint range: 0,05..3 m/s
Max. media temperature: 80C
Max. pressure: 30bar

Process connection G1/2"
Power supply: 24Vac


KTF00-65-2M

Honeywell Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -30...105C
Cable length: 2m
Packing unit quantity: 1


KTF00-65-2M-300

Honeywell Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -20...260C
Cable length: PFTE, 2m
Packing unit quantity: 1


KTF00-65-2M-B

Honeywell Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -30...105C
Cable length: 2m
Packing unit quantity: 50


KTF00-65-5M-B

Honeywell Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -30...105C
Cable length: 5m
Packing unit quantity: 50


KTF01-65-2M

Honeywell Water temperature sensor Ni1000, cable type

Protection class: IP65
Temperature element: Ni1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm
Cable length: 2m


Temperature range: -30...105C


KTF01-65-2M-300

Honeywell Water temperature sensor Ni1000, cable type

Protection class: IP65
Temperature element: Ni1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm
Cable length: 2m


Temperature range: -20...260C


KTF10-65-2M

Honeywell Water temperature sensor NTC, cable type

Watertight temperature sensor with sensor cartridge.
Protection class: IP65
Metal immersion spring is not included
Temperature range: -30...105C
Mounting place: universal
Immersion depth: 50mm
Sensing element (dia x L): 6mm|50mm
Wiring terminals: 2
Cable length: 2m


Temperature element: NTC10k


KTF20-65-2M

Honeywell Water temperature sensor NTC, cable type

Watertight temperature sensor with sensor cartridge.
Protection class: IP65
Metal immersion spring is not included
Temperature range: -30...105C
Mounting place: universal
Immersion depth: 50mm
Sensing element (dia x L): 6mm|50mm
Wiring terminals: 2
Cable length: 2m


Temperature element: NTC20k


LF-MF

Honeywell Air duct and immersion temperature sensor, NTC
Flange

Mounting flange for air-duct application (10 pieces)



LF20-1P65-5M

Honeywell Air duct temperature sensor, NTC

Humidity 5..95 %rh, non condensing.
Temperature element: NTC20k
Temperature range: -30...80C
Mounting place: air duct
Wiring terminals: 2
Cable length: 5m
Protection class: IP65


Immersion depth: 157mm


LF20-3P65-5M

Honeywell Air duct temperature sensor, NTC

Humidity 5..95 %rh, non condensing.
Temperature element: NTC20k
Temperature range: -30...80C
Mounting place: air duct
Wiring terminals: 2
Cable length: 5m
Protection class: IP65


Immersion depth: 307mm


LFH00-2B65

Honeywell Air Duct Temperature and R.H. sensor, LFH

For sensing or controlling of duct temperature and relative humidity.
Output voltage: 2 outputs:
0..10V for Temperature
0..10V for Relative Humidity
Temperature range: -5...55C
R.H. range: 10...90%rh
Protection class: IP65 for enclosure; IP40 for sensing part
Mounting place: air duct
Immersion depth: 230mm
Power supply: 24Vac

Transmitters and additional passive temperature sensor
Temperature element: Pt1000
Wiring terminals: 6


LFH01-2B65

Honeywell Air Duct Temperature and R.H. sensor, LFH

For sensing or controlling of duct temperature and relative humidity.
Output voltage: 2 outputs:
0..10V for Temperature
0..10V for Relative Humidity
Temperature range: -5...55C
R.H. range: 10...90%rh
Protection class: IP65 for enclosure; IP40 for sensing part
Mounting place: air duct
Immersion depth: 230mm
Power supply: 24Vac

Transmitters and additional passive temperature sensor
Temperature element: Ni1000
Wiring terminals: 6


LFH10-2B65

Honeywell Air Duct Temperature and R.H. sensor, LFH

For sensing or controlling of duct temperature and relative humidity.
Output voltage: 2 outputs:
0..10V for Temperature
0..10V for Relative Humidity
Temperature range: -5...55C
R.H. range: 10...90%rh
Protection class: IP65 for enclosure; IP40 for sensing part
Mounting place: air duct
Immersion depth: 230mm
Power supply: 24Vac

Transmitters and additional passive temperature sensor
Temperature element: NTC10k
Wiring terminals: 6


LFH20-2B65

Honeywell Air Duct Temperature and R.H. sensor, LFH

For sensing or controlling of duct temperature and relative humidity.
Output voltage: 2 outputs:
0..10V for Temperature
0..10V for Relative Humidity
Temperature range: -5...55C
R.H. range: 10...90%rh
Protection class: IP65 for enclosure; IP40 for sensing part
Mounting place: air duct
Immersion depth: 230mm
Power supply: 24Vac

Transmitters and additional passive temperature sensor
Temperature element: NTC20k
Wiring terminals: 6


LFHV-2B65

Honeywell Air Duct Temperature and R.H. sensor, LFH

For sensing or controlling of duct temperature and relative humidity.
Output voltage: 2 outputs:
0..10V for Temperature
0..10V for Relative Humidity
Temperature range: -5...55C
R.H. range: 10...90%rh
Protection class: IP65 for enclosure; IP40 for sensing part
Mounting place: air duct
Immersion depth: 230mm
Power supply: 24Vac

Transmitters only
Temperature element: no
Wiring terminals: 4


LFV-050-1B65

Honeywell Air duct and immersion temperature transmitter, 0..10V

Protection class: IP65
Output signal: 0..10V
Housing (HxWxD): 56mm|81mm|40mm
Mounting place: duct + well
Wiring terminals: 3
Power supply: 24Vacdc
Humidity 5..95 %rh, non condensing.

Transmitter without immersion well, nor flange
Immersion depth: 150mm
Temperature range: 0...50C


LFV-050-3B65

Honeywell Air duct and immersion temperature transmitter, 0..10V

Protection class: IP65
Output signal: 0..10V
Housing (HxWxD): 56mm|81mm|40mm
Mounting place: duct + well
Wiring terminals: 3
Power supply: 24Vacdc
Humidity 5..95 %rh, non condensing.

Transmitter without immersion well, nor flange
Immersion depth: 300mm
Temperature range: 0...50C


LFV-100-1B65

Honeywell Air duct and immersion temperature transmitter, 0..10V

Protection class: IP65
Output signal: 0..10V
Housing (HxWxD): 56mm|81mm|40mm
Mounting place: duct + well
Wiring terminals: 3
Power supply: 24Vacdc
Humidity 5..95 %rh, non condensing.

Transmitter without immersion well, nor flange
Immersion depth: 150mm
Temperature range: 0...100C


LFV-100-3B65

Honeywell Air duct and immersion temperature transmitter, 0..10V

Protection class: IP65
Output signal: 0..10V
Housing (HxWxD): 56mm|81mm|40mm
Mounting place: duct + well
Wiring terminals: 3
Power supply: 24Vacdc
Humidity 5..95 %rh, non condensing.

Transmitter without immersion well, nor flange
Immersion depth: 300mm
Temperature range: 0...100C


LP914A1003/U

Honeywell Pneumatic temperature sensor, LP914

Pneumatic sensor for control of hot water or warm air, in heating and air-conditioning systems.
Max. safe air pressure: 175kPa
Max. media temperature: 130C
Supply air pressure: 125kPa
Pressure output: 21...103kPa
Air connection: push-on barb connector for 6 mm or 1/4" O.D. tube
Action: direct acting


Temperature range: -40...70C
Immersion depth: 380mm
Mounting: duct or well


LP914A1029/U

Honeywell Pneumatic temperature sensor, LP914

Pneumatic sensor for control of hot water or warm air, in heating and air-conditioning systems.
Max. safe air pressure: 175kPa
Max. media temperature: 130C
Supply air pressure: 125kPa
Pressure output: 21...103kPa
Air connection: push-on barb connector for 6 mm or 1/4" O.D. tube
Action: direct acting


Temperature range: 5...115C
Immersion depth: 380mm
Mounting: duct or well


LP914A1045/U

Honeywell Pneumatic temperature sensor, LP914

Pneumatic sensor for control of hot water or warm air, in heating and air-conditioning systems.
Max. safe air pressure: 175kPa
Max. media temperature: 130C
Supply air pressure: 125kPa
Pressure output: 21...103kPa
Air connection: push-on barb connector for 6 mm or 1/4" O.D. tube
Action: direct acting


Temperature range: -40...70C
Immersion depth: 175mm
Mounting: duct or well


LP914A1052/U

Honeywell Pneumatic temperature sensor, LP914

Pneumatic sensor for control of hot water or warm air, in heating and air-conditioning systems.
Max. safe air pressure: 175kPa
Max. media temperature: 130C
Supply air pressure: 125kPa
Pressure output: 21...103kPa
Air connection: push-on barb connector for 6 mm or 1/4" O.D. tube
Action: direct acting


Temperature range: 5...115C
Immersion depth: 175mm
Mounting: well


LP914A1144/U

Honeywell Pneumatic temperature sensor, LP914

Pneumatic sensor for control of hot water or warm air, in heating and air-conditioning systems.
Max. safe air pressure: 175kPa
Max. media temperature: 130C
Supply air pressure: 125kPa
Pressure output: 21...103kPa
Air connection: push-on barb connector for 6 mm or 1/4" O.D. tube
Action: direct acting


Temperature range: -5...50C
Immersion depth: 380mm
Mounting: duct or well


LP915A1044/U

Honeywell Pneumatic temperature sensor, LP915

One-pipe, direct-acting temperature sensor used with RP908 or RP920 Controllers to provide proportional control of pneumatic valve or damper actuators. Averaging, liquid-filled element for duct mounting.
Max. safe air pressure: 172kPa
Max. media temperature: 118C
Supply air pressure: 124kPa
Pressure output: 21...103kPa
Air connection: push-on barb connector for 4 mm or 5/32" and 6 mm or 1/4" O.D. tube
Capillary tube length: 5.6m
Temperature range: -18...93C
Mounting: duct
Action: direct acting


LS20-15

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN15/20; pipe diameter 15 mm



LS20-18

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN 15/20; pipe diameter 18 mm



LS20-22

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN15/20; pipe diameter 22 mm



LS25-18

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN25; pipe diameter 18 mm



LS25-22

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN25; pipe diameter 22 mm



LS25-28

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN25; pipe diameter 28 mm



LS32-22

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN32; pipe diameter 22 mm



LS32-28

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN32; pipe diameter 28 mm



LS32-35

Honeywell Four-way rotary valve PN6, compact
Loetstutzen

For valves DN32; pipe diameter 35 mm



LSU25-18

Honeywell Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN25, pipe size 18 mm



LSU25-22

Honeywell Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN25, pipe size 22 mm



LSU25-28

Honeywell Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN25, pipe size 28 mm



LSU32-22

Honeywell Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN32, pipe size 22 mm



LSU32-28

Honeywell Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN32, pipe size 28 mm



LSU32-35

Honeywell Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN32, pipe size 35 mm



M100-AG

Honeywell V5004T Kombi-QM Pressure Independent Balancing and Control Valve
Accessories for V5004TY Kombi QM (DN15-DN25) valves with 2.9 mm stroke

M100 actuators thermoelectric, 4.0 mm effective stroke, 90N, on/off.



M100-AO

Honeywell V5004T Kombi-QM Pressure Independent Balancing and Control Valve
Accessories for V5004TY Kombi QM (DN15-DN25) valves with 2.9 mm stroke

M100 actuators thermoelectric, 4.0 mm effective stroke, 90N, on/off.



M100-BG

Honeywell V5004T Kombi-QM Pressure Independent Balancing and Control Valve
Accessories for V5004TY Kombi QM (DN15-DN25) valves with 2.9 mm stroke

M100 actuators thermoelectric, 4.0 mm effective stroke, 90N, on/off.



M100-BO

Honeywell V5004T Kombi-QM Pressure Independent Balancing and Control Valve
Accessories for V5004TY Kombi QM (DN15-DN25) valves with 2.9 mm stroke

M100 actuators thermoelectric, 4.0 mm effective stroke, 90N, on/off.



M44-MOD-1M

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 1 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-1M/U

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 1 meter, 3 x 0,22 mm2 (1 piece)



M44-MOD-1MH

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 1 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-1MH/U

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 1 meter, 3 x 0,22 mm2 (1 piece)



M44-MOD-3M

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 3 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-3MH

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 3 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-5M

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 5 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-5MH

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 5 meter, 3 x 0,22 mm2 (10 pieces)



M44-VA10

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Valve Adapters M30 x 1,5

Valve adapter with closing dimension 11,5mm (10 pieces)



M44-VA50

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Valve Adapters M30 x 1,5

Valve adapter with closing dimension 10,5mm (10 pieces)



M4410C4000

Honeywell Actuator thermoelectric for zone control 2,5 mm 100 N, M4410C/L

Electrical actuator on/off control.
Protection class: IP54
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Actuator supplied with M30 x 1,5 valve adapter (VA80); other adapters on request.
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 5 mm.
Fits to closing dimension 11,5 +/- 0,3 mm.
Stem force: 100N
Control input signal: 2-pt
Stroke: 2.5mm
Runtime: 4min
Cable length: 1m

2,5 mm; 100 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
End switches: no
Initial current: 0.3mA


M4410C4500

Honeywell Actuator thermoelectric for zone control 2,5 mm 100 N, M4410C/L

Electrical actuator on/off control.
Protection class: IP54
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Actuator supplied with M30 x 1,5 valve adapter (VA80); other adapters on request.
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 5 mm.
Fits to closing dimension 11,5 +/- 0,3 mm.
Stem force: 100N
Control input signal: 2-pt
Stroke: 2.5mm
Runtime: 4min
Cable length: 1m

2,5 mm; 100 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
End switches: no
Initial current: 0.3mA


M4410C4540

Honeywell Actuator thermoelectric for zone control 2,5 mm 100 N, M4410C/L

Electrical actuator on/off control.
Protection class: IP54
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Actuator supplied with M30 x 1,5 valve adapter (VA80); other adapters on request.
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 5 mm.
Fits to closing dimension 11,5 +/- 0,3 mm.
Stem force: 100N
Control input signal: 2-pt
Stroke: 2.5mm
Runtime: 4min
Cable length: 1m

2,5 mm; 100 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
End switches: 1
Initial current: 0.3mA


M4410E1510

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410

Electrical actuator for (radiator) valves with connection size M30 x 1,5. The actuator is supplied with the M44-VA10 adapter (closing dimension 11,5 mm). This suits the following valves:
V58xxA4, V58xxC4, VSO
V300, V2000
V2464, V2474
A separate adapter can be ordered (M44-VA50). With this adapter the actuator fits to the valves with closing dimension 10,5 mm.
Protection class: IP54
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 4 mm.
Stem force: 100N
Control input signal: 0..10V=
Stroke: 2.5mm
Power loss action: stem extends
Runtime: 75s
Cable length: optional: 1, 3 ,5m
Required materials: check accessories

2,5 mm; 100 N
Supply voltage: 24 Vac


M4410K1515

Honeywell Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410

Electrical actuator for (radiator) valves with connection size M30 x 1,5. The actuator is supplied with the M44-VA10 adapter (closing dimension 11,5 mm). This suits the following valves:
V58xxA4, V58xxC4, VSO
V300, V2000
V2464, V2474
A separate adapter can be ordered (M44-VA50). With this adapter the actuator fits to the valves with closing dimension 10,5 mm.
Protection class: IP54
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 4 mm.
Stem force: 100N
Control input signal: 0..10V=
Stroke: 2.5mm
Power loss action: stem extends
Runtime: 75s
Cable length: optional: 1, 3 ,5m
Required materials: check accessories

2,5 mm; 100 N
Supply voltage: 24 Vdc


M4410L4000

Honeywell Actuator thermoelectric for zone control 2,5 mm 100 N, M4410C/L

Electrical actuator on/off control.
Protection class: IP54
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Actuator supplied with M30 x 1,5 valve adapter (VA80); other adapters on request.
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 5 mm.
Fits to closing dimension 11,5 +/- 0,3 mm.
Stem force: 100N
Control input signal: 2-pt
Stroke: 2.5mm
Runtime: 4min
Cable length: 1m

2,5 mm; 100 N
Supply voltage: 230 Vac
Power loss action: stem retracts
End switches: no
Initial current: 0.5mA


M4410L4500

Honeywell Actuator thermoelectric for zone control 2,5 mm 100 N, M4410C/L

Electrical actuator on/off control.
Protection class: IP54
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Actuator supplied with M30 x 1,5 valve adapter (VA80); other adapters on request.
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 5 mm.
Fits to closing dimension 11,5 +/- 0,3 mm.
Stem force: 100N
Control input signal: 2-pt
Stroke: 2.5mm
Runtime: 4min
Cable length: 1m

2,5 mm; 100 N
Supply voltage: 230 Vac
Power loss action: stem extends
End switches: no
Initial current: 0.5mA


M4410L4540

Honeywell Actuator thermoelectric for zone control 2,5 mm 100 N, M4410C/L

Electrical actuator on/off control.
Protection class: IP54
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Actuator supplied with M30 x 1,5 valve adapter (VA80); other adapters on request.
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 5 mm.
Fits to closing dimension 11,5 +/- 0,3 mm.
Stem force: 100N
Control input signal: 2-pt
Stroke: 2.5mm
Runtime: 4min
Cable length: 1m

2,5 mm; 100 N
Supply voltage: 230 Vac
Power loss action: stem extends
End switches: 1
Initial current: 0.5mA


M5410C1001

Honeywell Fast motoric actuator for terminal unit/radiator, 6,5 mm 90 N, M5410

Electrical actuator on/off control, for valve series VS, V58.. DN15/20 and V100/V2000 TRV-series.
Protection class: IP54
Manual operation with valve cap.
Stem force: 90N
Control input signal: 2-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 3,6/16s
Cable length: 1.5m

6,5 mm; 90 N
Supply voltage: 24 Vac/dc


M5410L1001

Honeywell Fast motoric actuator for terminal unit/radiator, 6,5 mm 90 N, M5410

Electrical actuator on/off control, for valve series VS, V58.. DN15/20 and V100/V2000 TRV-series.
Protection class: IP54
Manual operation with valve cap.
Stem force: 90N
Control input signal: 2-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 3,6/16s
Cable length: 1.5m

6,5 mm; 90 N
Supply voltage: 230 Vac


M6061A1013

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 10Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 1.5min
Position feedback: no
End switches: optional


M6061A1021

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 20Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 1.6min
Position feedback: no
End switches: optional


M6061A1039

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 30Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 2.3min
Position feedback: no
End switches: optional


M6061A1047

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 40Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 3.5min
Position feedback: no
End switches: optional


M6061L1019

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 10Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 1.5min
Position feedback: no
End switches: optional


M6061L1027

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 20Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 1.6min
Position feedback: no
End switches: optional


M6061L1035

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 30Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 2.3min
Position feedback: optional
End switches: optional


M6061L1043

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 40Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 3.5min
Position feedback: no
End switches: optional


M6063A1003

Honeywell Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 24 Vac
End switches: no


M6063A4007

Honeywell Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 24 Vac
End switches: 2


M6063L1009

Honeywell Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 230 Vac
End switches: no


M6063L4003

Honeywell Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 230 Vac
End switches: 2


M6410C2023

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410C2031

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410C4029

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6410C4037

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6410L2023

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 230 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410L2031

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 230 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410L4029

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 230 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6410L4037

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 230 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6422L1003

Honeywell Actuator for V5421B1090

Protection class: IP54
Supply voltage: 230 Vac
Control input signal: 3-pt
Built in rotation limiter: no
Manual operation: yes
End switches: optional
Runtime: 150s
Torque: 40Nm


M7061E1012

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Modulating control
Torque: 10Nm
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Runtime: 1.5min
Position feedback: optional
End switches: no


M7061E1020

Honeywell Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Modulating control
Torque: 20Nm
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Runtime: 3.0min
Position feedback: optional
End switches: no


M7410A1001

Honeywell Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.
Protection class: IP43
Position indication: with red indicator
Manual operation with valve cap.
Supply voltage: 24 Vac
Stem force: 90N
Control input signal: 3-pt
Stroke: 2.5mm
Runtime: 57s

2,5 mm; 90 N
Cable length: 0.9m


M7410A1001-10M

Honeywell Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.
Protection class: IP43
Position indication: with red indicator
Manual operation with valve cap.
Supply voltage: 24 Vac
Stem force: 90N
Control input signal: 3-pt
Stroke: 2.5mm
Runtime: 57s

2,5 mm; 90 N
Cable length: 10m


M7410A1001-3M

Honeywell Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.
Protection class: IP43
Position indication: with red indicator
Manual operation with valve cap.
Supply voltage: 24 Vac
Stem force: 90N
Control input signal: 3-pt
Stroke: 2.5mm
Runtime: 57s

2,5 mm; 90 N
Cable length: 3m


M7410A1001-5M

Honeywell Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.
Protection class: IP43
Position indication: with red indicator
Manual operation with valve cap.
Supply voltage: 24 Vac
Stem force: 90N
Control input signal: 3-pt
Stroke: 2.5mm
Runtime: 57s

2,5 mm; 90 N
Cable length: 5m


M7410C1007

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 1.5m


M7410C1007-10M

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 10m


M7410C1007-3M

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 3m


M7410C1007-5M

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 5m


M7410C1015

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 1.5m


M7410C1015-5M

Honeywell Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 5m


M7410E1002

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: no
End switches: no
Runtime: 150s
Cable length: 1.5m


M7410E1002-10M

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: no
End switches: no
Runtime: 150s
Cable length: 10m


M7410E1028

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Manual operation: no
End switches: no
Runtime: 150s
Cable length: 1.5m


M7410E2026

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: yes
End switches: no
Runtime: 150s
Cable length: 1.5m


M7410E2034

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Manual operation: yes
End switches: no
Runtime: 150s
Cable length: 1.5m


M7410E4022

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: yes
End switches: 2
Runtime: 150s
Cable length: 1.5m


M7410E4030

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Manual operation: yes
End switches: 2
Runtime: 150s
Cable length: 1.5m


M7410E5001

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

2,7 mm; 90 N; for valve series V5004TY. 2,5 mm; 90 N; for valve series V5822A, V5823A/C, V5832A, V5833A/C, VSO and TRV V20/V30
Stem force: 90N
Stroke: 2.5mm
Manual operation: no
End switches: no
Runtime: 70s
Cable length: 1.5m


M7410E5001-10M

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

2,7 mm; 90 N; for valve series V5004TY. 2,5 mm; 90 N; for valve series V5822A, V5823A/C, V5832A, V5833A/C, VSO and TRV V20/V30
Stem force: 90N
Stroke: 2.5mm
Manual operation: no
End switches: no
Runtime: 70s
Cable length: 10m


M7410E5001-3M

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

2,7 mm; 90 N; for valve series V5004TY. 2,5 mm; 90 N; for valve series V5822A, V5823A/C, V5832A, V5833A/C, VSO and TRV V20/V30
Stem force: 90N
Stroke: 2.5mm
Manual operation: no
End switches: no
Runtime: 70s
Cable length: 3m


M7410E5001-5M

Honeywell Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=

2,7 mm; 90 N; for valve series V5004TY. 2,5 mm; 90 N; for valve series V5822A, V5823A/C, V5832A, V5833A/C, VSO and TRV V20/V30
Stem force: 90N
Stroke: 2.5mm
Manual operation: no
End switches: no
Runtime: 70s
Cable length: 5m


M7410G1008

Honeywell LON actuator for radiator/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Electrical actuator with LON input signal.
Protection class: IP42
Position indication: with red indicator
LonMark(R) profile: input SNVT percent 0-100%
Transceiver type: FTT 10A
Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
Supply voltage: 24 Vac
Control input signal: LON
Cable length: 1.5m

2,5 mm; 90 N; for valve series: V100 (thermostatic valves), V58..A4, V58..C4, VSO
Stem force: 90N
Stroke: 2.5mm
Runtime: 53s


M7410G1016

Honeywell LON actuator for radiator/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Electrical actuator with LON input signal.
Protection class: IP42
Position indication: with red indicator
LonMark(R) profile: input SNVT percent 0-100%
Transceiver type: FTT 10A
Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
Supply voltage: 24 Vac
Control input signal: LON
Cable length: 1.5m

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Runtime: 150s


M7410G1024

Honeywell LON actuator for radiator/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Electrical actuator with LON input signal.
Protection class: IP42
Position indication: with red indicator
LonMark(R) profile: input SNVT percent 0-100%
Transceiver type: FTT 10A
Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
Supply voltage: 24 Vac
Control input signal: LON
Cable length: 1.5m

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Runtime: 150s


MAU8/MS

Honeywell Accessories for Pressure Switches / Transmitters
Accessories for Differential Switches / Transmitters

Male adapter union, O-ring NBR



MAU8/NST

Honeywell Accessories for Pressure Switches / Transmitters
Accessories for Differential Switches / Transmitters

Male adapter union, O-ring FPM



MCD3

Honeywell Relay module for on/off and 3-pt control

Two channel signal converter module.
For a signal change from 0..10Vdc (from external controller) into on/off and 3-pt control relay contact output.
Input signal: 2 x 0..10 Vdc
Output signal: relay K1 and K2 SPST contact 240V 0,2 A supplying 3-pt control of first analogue input
relay K3 SPDT contact 240V 2 A, supplying on/off control of second analogue input
Mounting: DIN rail
Power supply: 24Vacdc


MCE1

Honeywell Voltage level switch

For conversion of an analogue output signal from a controller into an on/off output signal.
Input signal: 0..10 Vdc
Output signal: relay contact SPDT 250 V, 4 A; relay on with input voltage > 3 V, relay off with input voltage < 2,5 V
Manual operation functions: override switch with auto-off-on position
LED functions: yellow LED showing relay status
Mounting: DIN rail
Power supply: 24Vacdc


MCE2

Honeywell Conversion module 24Vdc/relay

For conversion of an 24 Vdc signal from a digital output of a controller into an on/off output signal.
Input signal: 0 or 24 Vdc
Output signal: relay contact SPDT 250 V, 6 A; relay on with 24 V, off with 0 V input signal
Manual operation functions: override switch with auto-off-on position
LED functions: yellow LED showing relay status
Mounting: DIN rail
Power supply: 24Vacdc


MCE3

Honeywell Conversion module 0..10Vdc - relay, 3 channel

Three channel signal converter module.
For a signal change from 0..10Vdc (from external controller) into an on/off relay contact output.
Input signal: 3x 0..10 Vdc
Output signal: relay K1/K2 SPDT contact 240 V, 2 A
relay K3 SPST contact 240 V, 2 A
Mounting: DIN rail
Power supply: 24Vacdc


MCM1

Honeywell Status display module, 4 channel

Status indication module for external contacts.
Input signal: 4 x external potential free contacts
Output signal: 4 x 24Vacdc (from power supply)
Manual operation functions: 4 x switch for LED status inversion
LED functions: 4 x red or green LED showing the status of the input
Mounting: DIN rail
Power supply: 24Vacdc


MCP1

Honeywell Manual positioning module

Manual positioning module for analogue output signals to manually adjust damper and valve actuators or to provide a fixed position.
Input signal: 0..10 Vdc
Output signal: 0..10 Vdc from input or from potentiometer (max. 1 mA)
Manual operation functions: potentiometer to adjust output signal 0..10Vdc; switch with auto/manual position
LED functions: red LED, intensity shows output level
Mounting: DIN rail
Potential free contact for feedback of manual override.
Power supply: 24Vacdc


ML6420A3007

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 24 Vac
Power loss action: no
Manual operation: yes
Runtime: 1.0min
Spring return: no


ML6420A3015

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 230 Vac
Power loss action: no
Manual operation: yes
Runtime: 1.0min
Spring return: no


ML6420A3023

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 24 Vac
Power loss action: no
Manual operation: yes
Runtime: 0.5min
Spring return: no


ML6420A3031

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 230 Vac
Power loss action: no
Manual operation: yes
Runtime: 0.5min
Spring return: no


ML6420A3072

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 24 Vac
Power loss action: no
Manual operation: no
Runtime: 1.0min
Spring return: no


ML6421A3005

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

20 mm; 1800 N
Supply voltage: 24 Vac
Stroke: 20mm
Runtime: 1.9min
Position feedback: optional


ML6421A3013

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

20 mm; 1800 N
Supply voltage: 230 Vac
Stroke: 20mm
Runtime: 1.9min
Position feedback: no


ML6421B3004

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

38 mm; 1800 N
Supply voltage: 24 Vac
Stroke: 38mm
Runtime: 3.5min
Position feedback: optional


ML6421B3012

Honeywell Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

38 mm; 1800 N
Supply voltage: 230 Vac
Stroke: 38mm
Runtime: 3.5min
Position feedback: no


ML6425A3006

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 24 Vac
Power loss action: stem extends
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6425A3014

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 230 Vac
Power loss action: stem extends
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6425B3005

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 24 Vac
Power loss action: stem retracts
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6425B3021

Honeywell Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 230 Vac
Power loss action: stem retracts
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6435B1008

Honeywell Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435

Electrical actuator floating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40)
Protection class: IP54
Approved according DIN EN 14597 in combination with V5825B.
Stem force: 400N
Control input signal: 3-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 60s
Spring return: yes

6,5 mm; 400 N
Supply voltage: 24 Vac


ML6435B1016

Honeywell Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435

Electrical actuator floating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40)
Protection class: IP54
Approved according DIN EN 14597 in combination with V5825B.
Stem force: 400N
Control input signal: 3-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 60s
Spring return: yes

6,5 mm; 400 N
Supply voltage: 230 Vac


ML7420A6009

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N
Control input signal: 0/2..10V=
Power loss action: no
Manual operation: yes
Runtime: 1.0min
Spring return: no
Position feedback: 2..10V=


ML7420A6017

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N
Control input signal: 0/2..10V=
Power loss action: no
Manual operation: yes
Runtime: 0.5min
Spring return: no
Position feedback: 2..10V=


ML7420A6025

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N
Control input signal: 2..10V=
Power loss action: no
Manual operation: no
Runtime: 1.0min
Spring return: no
Position feedback: no


ML7421A3004

Honeywell Actuator 0/2..10V, 20/38 mm 1800 N, ML7421

Electrical actuator modulating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: selectable: closed, half open, open
Position feedback: 2..10V=
End switches: optional
Supply voltage: 24 Vac
Stem force: 1800N
Control input signal: 0/2..10V=; 0/4..20mA
Manual operation: yes

20 mm; 1800 N
Stroke: 20mm
Runtime: 1.9min


ML7421B3003

Honeywell Actuator 0/2..10V, 20/38 mm 1800 N, ML7421

Electrical actuator modulating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: selectable: closed, half open, open
Position feedback: 2..10V=
End switches: optional
Supply voltage: 24 Vac
Stem force: 1800N
Control input signal: 0/2..10V=; 0/4..20mA
Manual operation: yes

38 mm; 1800 N
Stroke: 38mm
Runtime: 3.5min


ML7425A6008

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N, Spring return
Control input signal: 0/2..10V=
Power loss action: stem extends
Manual operation: no
Runtime: 1.8min
Spring return: yes
Position feedback: 2..10V=


ML7425B6007

Honeywell Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N, Spring return
Control input signal: 0/2..10V=
Power loss action: stem retracts
Manual operation: no
Runtime: 1.8min
Spring return: yes
Position feedback: 2..10V=


ML7430E1005

Honeywell Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435

Electrical actuator modulating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40).
Protection class: IP54
For ML7435E1004: approved according DIN EN 14597 in combination with V5825B.
Supply voltage: 24 Vac
Stem force: 400N
Control input signal: 0/2..10V=
Stroke: 6.5mm

6,5 mm; 400 N
Power loss action: no
Manual operation: yes
Runtime: 15s
Spring return: no


ML7435E1004

Honeywell Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435

Electrical actuator modulating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40).
Protection class: IP54
For ML7435E1004: approved according DIN EN 14597 in combination with V5825B.
Supply voltage: 24 Vac
Stem force: 400N
Control input signal: 0/2..10V=
Stroke: 6.5mm

6,5 mm; 400 N
Power loss action: stem retracts
Manual operation: no
Runtime: 60s
Spring return: yes


MP904A5047

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 21, 35, 70
Positioner: yes
Effective diaphragm area: 146cm2
Net force at 0 kPa pressure: 550N
Net force at 140 kPa pressure: 600N
Ambient temperature: -30...70C


MP904B5037

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 21...91
Positioner: no
Effective diaphragm area: 146cm2
Net force at 0 kPa pressure: 270N
Net force at 140 kPa pressure: 600N
Ambient temperature: -30...90C


MP904B5052

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 49...91
Positioner: no
Effective diaphragm area: 146cm2
Net force at 0 kPa pressure: 550N
Net force at 140 kPa pressure: 600N
Ambient temperature: -30...90C


MP904C1026

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 21, 35, 70
Positioner: yes
Effective diaphragm area: 65cm2
Net force at 0 kPa pressure: 280N
Net force at 140 kPa pressure: 250N
Ambient temperature: -30...70C


MP904D1032

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 14..49
Positioner: no
Effective diaphragm area: 65cm2
Net force at 0 kPa pressure: 70N
Net force at 140 kPa pressure: 500N
Ambient temperature: -30...90C


MP904D1040

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 49...91
Positioner: no
Effective diaphragm area: 65cm2
Net force at 0 kPa pressure: 280N
Net force at 140 kPa pressure: 250N
Ambient temperature: -30...90C


MP904D1057

Honeywell Pneumatic damper actuator, MP904

Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation systems.
Max. operating pressure: 140kPa
Air connection: barb fitting for 6 mm 1/4" polyethylene tubing
Pressure operating range for MP904A,C models field adjustable for 3 spans.
Max. safe air pressure: 210kPa
Stroke: 90mm


Pressure range kPa: 21...91
Positioner: no
Effective diaphragm area: 65cm2
Net force at 0 kPa pressure: 110N
Net force at 140 kPa pressure: 250N
Ambient temperature: -30...90C


MP913B1068

Honeywell Pneumatic damper actuator with shaft connection, MP913

Pneumatic actuator for a damper that controls the volume of air in induction units, mixing boxes, and variable volume systems.
Max. operating pressure: 140kPa
Operating range: 21...91kPa
Air connection: metal barb type slip-on connector for 6 x 1 mm or 1/4" O.D. polyethylene tube
Shaft connection thread M10
Rolling diaphragm
Max. safe air pressure: 200kPa
Ambient temperature: -30...70C


Stroke: 90mm
Effective diaphragm area: 25cm2
Net force at 0 kPa pressure: 45N
Net force at 125 kPa pressure: 80N


MP913B1076

Honeywell Pneumatic damper actuator with shaft connection, MP913

Pneumatic actuator for a damper that controls the volume of air in induction units, mixing boxes, and variable volume systems.
Max. operating pressure: 140kPa
Operating range: 21...91kPa
Air connection: metal barb type slip-on connector for 6 x 1 mm or 1/4" O.D. polyethylene tube
Shaft connection thread M10
Rolling diaphragm
Max. safe air pressure: 200kPa
Ambient temperature: -30...70C


Stroke: 65mm
Effective diaphragm area: 25cm2
Net force at 0 kPa pressure: 45N
Net force at 125 kPa pressure: 80N


MP913C1074

Honeywell Pneumatic damper actuator with shaft connection, MP913

Pneumatic actuator for a damper that controls the volume of air in induction units, mixing boxes, and variable volume systems.
Max. operating pressure: 140kPa
Operating range: 21...91kPa
Air connection: metal barb type slip-on connector for 6 x 1 mm or 1/4" O.D. polyethylene tube
Shaft connection thread M10
Rolling diaphragm
Max. safe air pressure: 200kPa
Ambient temperature: -30...70C


Stroke: 70mm
Effective diaphragm area: 45cm2
Net force at 0 kPa pressure: 80N
Net force at 125 kPa pressure: 145N


MP953A5005

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 70C
Diaphragm: 5inch


MP953A5039

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 70C
Diaphragm: 8inch


MP953A5054

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

38 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 38mm
Action actuator stem: extends
Max. ambient temperature: 70C
Diaphragm: 13inch


MP953B5003

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 20mm
Action actuator stem: retracts
Max. ambient temperature: 70C
Diaphragm: 7inch


MP953C5001

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 13,8...48,3
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 5inch


MP953C5019

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 55,2...82,8
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 5inch


MP953C5027

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 5inch


MP953C5068

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 13,8...48,3
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 8inch


MP953C5076

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 55,2...82,8
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 8inch


MP953C5084

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 8inch


MP953C5142

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

38 mm
Pressure range kPa: 13,8...48,3
Adjustable start point: no
Positioner: no
Stroke: 38mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 13inch


MP953C5159

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

38 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 38mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 13inch


MP953D5009

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 55,2...82,8
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: retracts
Max. ambient temperature: 120C
Diaphragm: 7inch


MP953D5025

Honeywell Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: retracts
Max. ambient temperature: 120C
Diaphragm: 7inch


MR6-24-010

Honeywell Rotary Actuator, MR6

Electrical actuator for VBG6 6-way ball valve, DN15-20.
Actuator can easily mounted with a single screw.
Protection class: IP44
Position indication: scale plate
Torque: 8Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1m
Supply voltage: 24 Vac
Runtime: 75s


Control input signal: 0/2..10V=; 0/4..20mA
Position feedback: 0..10V=


MR6-24-2POS

Honeywell Rotary Actuator, MR6

Electrical actuator for VBG6 6-way ball valve, DN15-20.
Actuator can easily mounted with a single screw.
Protection class: IP44
Position indication: scale plate
Torque: 8Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1m
Supply voltage: 24 Vac
Runtime: 75s


Control input signal: 2-pt
Position feedback: no


MS4604F1010/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 230 Vac
End switches: no
Torque: 3.4Nm


MS4604F1210/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 230 Vac
End switches: 2
Torque: 3.4Nm


MS4609F1010/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 230 Vac
End switches: no
Torque: 9Nm


MS4609F1210/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 230 Vac
End switches: 2
Torque: 9Nm


MS8104F1010/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 24 Vac/dc
End switches: no
Torque: 3.4Nm


MS8104F1210/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 24 Vac/dc
End switches: 2
Torque: 3.4Nm


MS8109F1010/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 24 Vac/dc
End switches: no
Torque: 9Nm


MS8109F1210/U

Honeywell Fire Damper actuator 3/9 Nm

Fast-acting two-position spring return actuator for on/off damper control. The actuator accepts an on/off signal from a single-pole, singlethrow (SPST) controller. Reversible mounting allows actuator to be used for either clockwise (cw) or counterclockwise (ccw) spring rotation.
Rated for applications according to UL555S.
Protection class: IP40
End switch function/capacity: models with 2 SPST switches 250 V 5(3) A; fixed setting at 7o and 85o
Shaft mounting: for squared shafts max. 13 mm
Spring return: yes
Spring return timing: 15s
Runtime: 15s
No audible noise during holding
Patent pending design eliminates need for limit switches to reduce power consumption
Die-cast aluminium housing
Control input signal: 2-pt


Supply voltage: 24 Vac/dc
End switches: 2
Torque: 9Nm


MT-ADAPT-HP

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Adapters

Mounting adapter for Herz/Polytherm valves; 10 units



MT-ADAPT-HW

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Adapters

Extra mounting adapters M30 x 1,5; 10 units



MT-CABLE-10M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Plug-in cable (not for models with end switch)

Cable 10 meter; 10 units



MT-CABLE-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Plug-in cable (not for models with end switch)

Cable 2,5 meter; 10 units



MT-CABLE-5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Plug-in cable (not for models with end switch)

Cable 5 meter; 10 units



MT-CLIP

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Accessories

Extra mounting clips; 10 units



MT4-024-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-024-NC-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 2.5m


MT4-024-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-024-NO-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 2.5m


MT4-024S-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-024S-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-230-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT4-230-NC-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 2.5m


MT4-230-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT4-230-NO-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 2.5m


MT4-230S-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT4-230S-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT8-024-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-024-NC-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 2.5m


MT8-024-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-024-NO-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 2.5m


MT8-024S-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 6.5mm
End switches: 1
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-024S-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 6.5mm
End switches: 1
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-230-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MT8-230-NC-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 2.5m


MT8-230-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MT8-230-NO-2.5M

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 2.5m


MT8-230S-NC

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 6.5mm
End switches: 1
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MT8-230S-NO

Honeywell Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 6.5mm
End switches: 1
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MVC-40-AC3

Honeywell Programmable universal BACnet Building Controller, Excel Web II
Extra parts for Excel Web II

Strain relief; package of 10



MVC-80-AC1

Honeywell Programmable universal BACnet Building Controller, Excel Web II
Extra parts for Excel Web II

Terminal cover (color: RAL9011); package of 10



MVC-80-AC2

Honeywell Programmable universal BACnet Building Controller, Excel Web II
Extra parts for Excel Web II

Front door mounting accessory (color: RAL9011); package of 10



MVC-80H-CPSW1

Honeywell Controllers with ROHS II Certificate


MVC80, housing, no HMI



MVC-IO830A

Honeywell Controllers with ROHS II Certificate


Mixed I/O Module



MVN613A1500

Honeywell Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Floating control
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Runtime: 108s


MVN643A1500

Honeywell Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Floating control
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
Runtime: 30s


MVN663A1500

Honeywell Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Floating control
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Runtime: 108s


MVN713A1500

Honeywell Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Modulating control. Control action reversable.
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Runtime: 90s


MVNAAA/U

Honeywell Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement valve adaptor standard profile, for VBG valves, DN15..DN32



MVNAT3/B

Honeywell Rotary Actuator, MVN
Accessories

Replacement screw terminal block, pluggable



N05010

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: no
Position feedback: 0/2..10V=
Runtime: 90/110s
Torque: 5Nm
Damper area: 1m2


N05010-SW2

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: 2
Position feedback: 0/2..10V=
Runtime: 90/110s
Torque: 5Nm
Damper area: 1m2


N05230-2POS

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 230 Vac
Control input signal: 2-pt
End switches: no
Position feedback: no
Runtime: max. 110s
Torque: 5Nm
Damper area: 1m2


N0524

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: no
Position feedback: no
Runtime: 110s
Torque: 5Nm
Damper area: 1m2


N0524-SW2

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: 2
Position feedback: no
Runtime: 110s
Torque: 5Nm
Damper area: 1m2


N10010

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: no
Position feedback: 0/2..10V=
Runtime: 90/110s
Torque: 10Nm
Damper area: 2m2


N10010-SW2

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: 2
Position feedback: 0/2..10V=
Runtime: 90/110s
Torque: 10Nm
Damper area: 2m2


N10230-2POS

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 230 Vac
Control input signal: 2-pt
End switches: no
Position feedback: no
Runtime: max. 140s
Torque: 10Nm
Damper area: 2m2


N1024

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: no
Position feedback: no
Runtime: 110s
Torque: 10Nm
Damper area: 2m2


N1024-SW2

Honeywell Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: 2
Position feedback: no
Runtime: 110s
Torque: 10Nm
Damper area: 2m2


N12-100

Honeywell Electronic thermostats (SmartTemp)
Accessories / Immersion Tubes

N1/2, conical NPT



N12-250

Honeywell Electronic thermostats (SmartTemp)
Accessories / Immersion Tubes

N1/2, conical NPT



N20010

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Built in rotation limiter: yes
End switches: optional
Position feedback: 0/2..10V=
Runtime: 95s
Torque: 20Nm
Damper area: 4m2


N20010-SW2

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Built in rotation limiter: yes
End switches: 2
Position feedback: 0/2..10V=
Runtime: 95s
Torque: 20Nm
Damper area: 4m2


N20230

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N20230-SW2

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: 2
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N2024

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N2024-SW2

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: 2
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N34010

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 6 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Built in rotation limiter: no
End switches: optional
Position feedback: 0/2..10V=
Runtime: 95s
Torque: 34Nm
Damper area: 6m2


N34230

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 6 square meters
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Built in rotation limiter: no
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 34Nm
Damper area: 6m2


N3424

Honeywell Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch.
When power is removed, the actuator remains in position.
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Actuator supplied with complete package mounting parts.
For modulating control models: Control input signal can be voltage or current.
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation.
Manual operation: yes

For damper area of 6 square meters
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Built in rotation limiter: no
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 34Nm
Damper area: 6m2


NPT1

Honeywell Accessories for Pressure Switches / Transmitters
Accessories

Adapter



NX-FAN-4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXL HVAC / NXS spare part fan size 4 (HVAC03-HVAC12, NXS0003-NXS0012)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXL HVAC / NXS spare part fan size 5 (HVAC16-HVAC31, NXS0016-NXS0031)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-6

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXL HVAC / NXS spare part fan size 6 (HVAC38-HVAC61, NXS0038-NXS0061)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-7

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXS spare part fan size 7 (NXS0072-NXS0105)
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NX-FAN-8

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, main fan, frame size 8, power 75 - 110 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-8-SET1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, fan kit, main fan and internal fan, frame size 8, 62 - 140 A
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-8-SET2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, fan kit, main fan and two internal fans, frame size 8, 168 - 205 A
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-9-FULLSET

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, fan kit, (main fans, 2x intern fans, fan power supply), frame size 9, power 132 - 160 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-9-SET

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, fan set, frame size 9, power 132 - 160 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-INT-FR9-1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, internal fan, 52 mm, frame size 9, power 132 - 160 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-INT-FR9-2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, internal fan, 80 mm, frame size 9, power 132 - 160 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-INT4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NX drives, internal fan, frame size 4, power 1.15 - 5 kW
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-INT5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NX drives, internal fan, frame size 5, power 7.5 - 15 kW
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-INT6-7

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NX drives, internal fan, frame size 6-7, power 18.5 - 55 kW
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-INT8

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, internal fan, frame size 8, 75 - 110 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-SUP-FR08

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, fan power supply kit, frame size 8, power 75 - 110 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NX-FAN-SUP-FR09

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NX Cooling Fans
Product description: NXS drives, fan power supply kit, frame size 9, power 132 - 160 kW
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXIP54FR4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL HVAC/NXS IP21 to IP54 upgrade kits
Product description: IP54 enclosure upgrade kit for NXL HVAC/NXS size 4 (HVAC03-HVAC12, NXS0003-NXS0012)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXIP54FR5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL HVAC/NXS IP21 to IP54 upgrade kits
Product description: IP54 enclosure upgrade kit for NXL HVAC/NXS size 5 (HVAC16-HVAC31, NXS0016-NXS0031)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXIP54FR6

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL HVAC/NXS IP21 to IP54 upgrade kits
Product description: IP54 enclosure upgrade kit for NXL HVAC/NXS size 6 (HVAC38-HVAC61, NXS0038-NXS0061)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXLOPTAA

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 3 digital inputs, 1 relay (NO/NC), 1 digital output
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXLPANC

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL Display panels
Product description: NXL standard 7-segment display
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXLPANRS

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL/NXS PC connection tools and cables
Product description: NXL RS232 adapter (for PC connection)
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXOPTA1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: standard NXS slot A board: 6 DI, 1 DO (open collector), 2 AI, 1 AO
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXOPTB2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 2 relays (1 NO, 1 NO/NC), 1 thermistor
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTB8

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 3 Pt100 input
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXOPTC2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: Modbus/N2 (RS485)
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXOPTC3

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: Profibus DP
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTC6

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: CANopen (slave)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTC7

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: DeviceNet
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTCJ

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: BACnet MS/TP (RS485)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXPANA

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXS Display panels
Product description: NXS standard alpha-numeric display
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXPANG

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXS Display panels
Product description: NXS special display for Cyrillic or Chinese letters
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXS-CONTROL-BOX

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Control Spares
Product description: Varnished control unit for NXS with enclosure
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXS0003V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 1.1kW
Low overload Icont: 3.1A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A
Brake chopper: integrated


NXS0003V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 1.1kW
Low overload Icont: 3.1A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A
Brake chopper: integrated


NXS0004V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 1.5kW
Low overload Icont: 4A
High overload (for Machines): 1.1kW
High overload Icont: 3.1A
Brake chopper: integrated


NXS0004V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 1.5kW
Low overload Icont: 4A
High overload (for Machines): 1.1kW
High overload Icont: 3.1A
Brake chopper: integrated


NXS0005V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 2.2kW
Low overload Icont: 5.4A
High overload (for Machines): 1.5kW
High overload Icont: 4A
Brake chopper: integrated


NXS0005V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 2.2kW
Low overload Icont: 5.4A
High overload (for Machines): 1.5kW
High overload Icont: 4A
Brake chopper: integrated


NXS0007V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 3kW
Low overload Icont: 7A
High overload (for Machines): 2.2kW
High overload Icont: 5.4A
Brake chopper: integrated


NXS0007V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 3kW
Low overload Icont: 7A
High overload (for Machines): 2.2kW
High overload Icont: 5.4A
Brake chopper: integrated


NXS0009V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7A
Brake chopper: integrated


NXS0009V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7A
Brake chopper: integrated


NXS0012V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A
Brake chopper: integrated


NXS0012V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A
Brake chopper: integrated


NXS0016V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A
Brake chopper: integrated


NXS0016V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A
Brake chopper: integrated


NXS0022V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 11kW
Low overload Icont: 22A
High overload (for Machines): 7.5kW
High overload Icont: 16A
Brake chopper: integrated


NXS0022V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 11kW
Low overload Icont: 22A
High overload (for Machines): 7.5kW
High overload Icont: 16A
Brake chopper: integrated


NXS0031V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 22A
Brake chopper: integrated


NXS0031V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 22A
Brake chopper: integrated


NXS0038V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A
Brake chopper: integrated


NXS0038V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A
Brake chopper: integrated


NXS0045V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 22kW
Low overload Icont: 45A
High overload (for Machines): 18.5kW
High overload Icont: 38A
Brake chopper: integrated


NXS0045V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 22kW
Low overload Icont: 45A
High overload (for Machines): 18.5kW
High overload Icont: 38A
Brake chopper: integrated


NXS0061V35A2H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 30kW
Low overload Icont: 61A
High overload (for Machines): 22kW
High overload Icont: 45A
Brake chopper: integrated


NXS0061V35A5H1

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 30kW
Low overload Icont: 61A
High overload (for Machines): 22kW
High overload Icont: 45A
Brake chopper: integrated


NXS0072V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 37kW
Low overload Icont: 72A
High overload (for Machines): 30kW
High overload Icont: 61A
Brake chopper: optional


NXS0072V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 37kW
Low overload Icont: 72A
High overload (for Machines): 30kW
High overload Icont: 61A
Brake chopper: optional


NXS0087V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 45kW
Low overload Icont: 87A
High overload (for Machines): 37kW
High overload Icont: 72A
Brake chopper: optional


NXS0087V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 45kW
Low overload Icont: 87A
High overload (for Machines): 37kW
High overload Icont: 72A
Brake chopper: optional


NXS0105V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 55kW
Low overload Icont: 105A
High overload (for Machines): 45kW
High overload Icont: 87A
Brake chopper: optional


NXS0105V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 55kW
Low overload Icont: 105A
High overload (for Machines): 45kW
High overload Icont: 87A
Brake chopper: optional


NXS0140V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 75kW
Low overload Icont: 140A
High overload (for Machines): 55kW
High overload Icont: 105A
Brake chopper: optional


NXS0140V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 75kW
Low overload Icont: 140A
High overload (for Machines): 55kW
High overload Icont: 105A
Brake chopper: optional


NXS0168V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 90kW
Low overload Icont: 170A
High overload (for Machines): 75kW
High overload Icont: 140A
Brake chopper: optional


NXS0168V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 90kW
Low overload Icont: 170A
High overload (for Machines): 75kW
High overload Icont: 140A
Brake chopper: optional


NXS0205V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 110kW
Low overload Icont: 205A
High overload (for Machines): 90kW
High overload Icont: 170A
Brake chopper: optional


NXS0205V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 110kW
Low overload Icont: 205A
High overload (for Machines): 90kW
High overload Icont: 170A
Brake chopper: optional


NXS0260V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 132kW
Low overload Icont: 261A
High overload (for Machines): 110kW
High overload Icont: 205A
Brake chopper: optional


NXS0260V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 132kW
Low overload Icont: 261A
High overload (for Machines): 110kW
High overload Icont: 205A
Brake chopper: optional


NXS0310V35A2H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Power: 160kW
Low overload Icont: 300A
High overload (for Machines): 132kW
High overload Icont: 245A
Brake chopper: optional


NXS0310V35A5H0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Power: 160kW
Low overload Icont: 300A
High overload (for Machines): 132kW
High overload Icont: 245A
Brake chopper: optional


NXS0385V35A2L0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, stand-alone cabinet; Emissions EN61800-3 (category 3)
Protection class: IP21
Power: 200kW
Low overload Icont: 385A
High overload (for Machines): 160kW
High overload Icont: 300A
Brake chopper: no


NXS0460V35A2L0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, stand-alone cabinet; Emissions EN61800-3 (category 3)
Protection class: IP21
Power: 250kW
Low overload Icont: 460A
High overload (for Machines): 200kW
High overload Icont: 385A
Brake chopper: no


NXS0590V35A2L0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, stand-alone cabinet; Emissions EN61800-3 (category 3)
Protection class: IP21
Power: 315kW
Low overload Icont: 590A
High overload (for Machines): 250kW
High overload Icont: 520A
Brake chopper: no


NXS0650V35A2L0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, stand-alone cabinet; Emissions EN61800-3 (category 3)
Protection class: IP21
Power: 355kW
Low overload Icont: 650A
High overload (for Machines): 315kW
High overload Icont: 590A
Brake chopper: no


NXS0730V35A2L0

Honeywell Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://hwll.co/inverter
1 phase input: no
3 phases input: yes

IP21, stand-alone cabinet; Emissions EN61800-3 (category 3)
Protection class: IP21
Power: 400kW
Low overload Icont: 730A
High overload (for Machines): 355kW
High overload Icont: 650A
Brake chopper: no


OPT-BT-MC02-5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Control Spares
Product description: 5 pieces of real time clock batteries
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


OPTB1

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 6 digital inputs/outputs (programmable)
HVAC400: yes
NXL HVAC: no
NXS: yes
HVAC232/402: no


OPTB2

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 1 Thermistor, 2x RO
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


OPTB4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 1 analog input (mA), 2 analog output (mA)
HVAC400: yes
NXL HVAC: yes
NXS: yes
HVAC232/402: no


OPTB5

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 3 relays (NO)
HVAC400: yes
NXL HVAC: yes
NXS: yes
HVAC232/402: no


OPTB9

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 1 relay, 5 Vac inputs (42..240 Vac)
HVAC400: yes
NXL HVAC: no
NXS: yes
HVAC232/402: no


OPTBF

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 1 analog input (mA/V), 1 relay (NO), 1 digital output (open collector)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


OPTBH

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: Pt1000, Ni1000, KTY84x
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: yes


OPTC4

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: LonWorks
HVAC400: yes
NXL HVAC: yes
NXS: yes
HVAC232/402: no


OPTE9

Honeywell Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: Modbus TCP, Ethernet/IP
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: yes


P100-100

Honeywell Immersion probe temperature sensor, stainless steel (P)

The temperature sensors have parts in contact with the medium made of stainless steel (1.4571 / 316Ti). The temperature is sensed by a Pt100 resistance thermometer confirming to EN 60 751. The sensor is connected in a 3-wire circuit. The Pt100 resistance thermometers are suitable for use in the temperature range of - 50 ... +400 degrees C.
Sensor as per EN60751: PT100, Class A, 3-wire
Process Connection: G1/2"
Material: Tube: high-grade steel 1.4571
Electrical connection: screw terminals
Ambient temperature: -20...100C
Max. pressure: 100bar
Temperature range: -50...400C
Mounting place: in well

Connection head: 1.4571/316Ti, Cabel entry: M16x1.5, Cable diameter: 6...9 mm, Protection class: IP67, Material housing and cover: 1.4571
Immersion depth: 100mm


P100-150

Honeywell Immersion probe temperature sensor, stainless steel (P)

The temperature sensors have parts in contact with the medium made of stainless steel (1.4571 / 316Ti). The temperature is sensed by a Pt100 resistance thermometer confirming to EN 60 751. The sensor is connected in a 3-wire circuit. The Pt100 resistance thermometers are suitable for use in the temperature range of - 50 ... +400 degrees C.
Sensor as per EN60751: PT100, Class A, 3-wire
Process Connection: G1/2"
Material: Tube: high-grade steel 1.4571
Electrical connection: screw terminals
Ambient temperature: -20...100C
Max. pressure: 100bar
Temperature range: -50...400C
Mounting place: in well

Connection head: 1.4571/316Ti, Cabel entry: M16x1.5, Cable diameter: 6...9 mm, Protection class: IP67, Material housing and cover: 1.4571
Immersion depth: 150mm


P100-200

Honeywell Immersion probe temperature sensor, stainless steel (P)

The temperature sensors have parts in contact with the medium made of stainless steel (1.4571 / 316Ti). The temperature is sensed by a Pt100 resistance thermometer confirming to EN 60 751. The sensor is connected in a 3-wire circuit. The Pt100 resistance thermometers are suitable for use in the temperature range of - 50 ... +400 degrees C.
Sensor as per EN60751: PT100, Class A, 3-wire
Process Connection: G1/2"
Material: Tube: high-grade steel 1.4571
Electrical connection: screw terminals
Ambient temperature: -20...100C
Max. pressure: 100bar
Temperature range: -50...400C
Mounting place: in well

Connection head: 1.4571/316Ti, Cabel entry: M16x1.5, Cable diameter: 6...9 mm, Protection class: IP67, Material housing and cover: 1.4571
Immersion depth: 200mm


P100-250

Honeywell Immersion probe temperature sensor, stainless steel (P)

The temperature sensors have parts in contact with the medium made of stainless steel (1.4571 / 316Ti). The temperature is sensed by a Pt100 resistance thermometer confirming to EN 60 751. The sensor is connected in a 3-wire circuit. The Pt100 resistance thermometers are suitable for use in the temperature range of - 50 ... +400 degrees C.
Sensor as per EN60751: PT100, Class A, 3-wire
Process Connection: G1/2"
Material: Tube: high-grade steel 1.4571
Electrical connection: screw terminals
Ambient temperature: -20...100C
Max. pressure: 100bar
Temperature range: -50...400C
Mounting place: in well

Connection head: 1.4571/316Ti, Cabel entry: M16x1.5, Cable diameter: 6...9 mm, Protection class: IP67, Material housing and cover: 1.4571
Immersion depth: 250mm


P2

Honeywell Room thermostat for industrial permises (TRM)
Accessories

Sealing



P2-TVS12-400100

Honeywell Electronic thermostats (SmartTemp)
External Sensors

100 mm immersion depth



P2-TVS12-400250

Honeywell Electronic thermostats (SmartTemp)
External Sensors

250 mm immersion depth



PA1

Honeywell Paddle flow switches for air (S6040)


Paddle set



PF20-65-2M

Honeywell Unit temperature sensor

Temperature sensor for air handling units, fancoil units or air outlets.
Protection class: IP65
Mounting place: air duct
Sensor supplied with mounting bracket. Sensing element size: diameter 6 mm, length 55 mm.
Temperature element: NTC20k
Temperature range: -30...70C
Wiring terminals: 2


Cable length: 2m


PF20-65-5M

Honeywell Unit temperature sensor

Temperature sensor for air handling units, fancoil units or air outlets.
Protection class: IP65
Mounting place: air duct
Sensor supplied with mounting bracket. Sensing element size: diameter 6 mm, length 55 mm.
Temperature element: NTC20k
Temperature range: -30...70C
Wiring terminals: 2


Cable length: 5m


PMK-EEM400

Honeywell Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D


Panel mounting kit for front door of cabinet



PP907A1008

Honeywell Pressure reducing valve with Filter Regulator Station, PP907

Provides reducing of inlet pressure to a constant operating pressure and filtering e.g. of condensates, dust, oil and rust particles.
Air consumption 30 Nl/h (500 sccm) at 500 kPa inlet pressure, max. 60 Nl/h (1000 sccm)
Upper limit of air capacity 10 Nm3/h
Outlet pressure gauge indication 0...2 bar (0...30 psi) full range
Sub-micron filter for dust separation and separation of condensates
Pressure relief valve, fixed at 175 kPa
Supply air pressure: max. 1000kPa
Pressure output: 10...175kPa


PROTPLUG-UP

Honeywell CARE software


Protection plug without license



PSHDB0012

Honeywell Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Open-collector
Configurable as min./max./window monitor
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Adjustable drop-in/drop-out delay
Media temp.: -20...80C
Protection class: IP65
Ambient temperature: -20...70C

Pressure Swith HMI
Pressure range: 0...1bar
Max. pressure: 3bar


PSHDB0032

Honeywell Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Open-collector
Configurable as min./max./window monitor
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Adjustable drop-in/drop-out delay
Media temp.: -20...80C
Protection class: IP65
Ambient temperature: -20...70C

Pressure Swith HMI
Pressure range: 0...3bar
Max. pressure: 9bar


PSHDB0062

Honeywell Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Open-collector
Configurable as min./max./window monitor
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Adjustable drop-in/drop-out delay
Media temp.: -20...80C
Protection class: IP65
Ambient temperature: -20...70C

Pressure Swith HMI
Pressure range: 0...6bar
Max. pressure: 21bar


PSHDB0202

Honeywell Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Open-collector
Configurable as min./max./window monitor
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Adjustable drop-in/drop-out delay
Media temp.: -20...80C
Protection class: IP65
Ambient temperature: -20...70C

Pressure Swith HMI
Pressure range: 0...20bar
Max. pressure: 60bar


PSHDM1002

Honeywell Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Open-collector
Configurable as min./max./window monitor
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Adjustable drop-in/drop-out delay
Media temp.: -20...80C
Protection class: IP65
Ambient temperature: -20...70C

Pressure Swith HMI
Pressure range: 0...0.1bar
Max. pressure: 0.9bar


PSHDM3002

Honeywell Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Open-collector
Configurable as min./max./window monitor
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Adjustable drop-in/drop-out delay
Media temp.: -20...80C
Protection class: IP65
Ambient temperature: -20...70C

Pressure Swith HMI
Pressure range: 0...0.3bar
Max. pressure: 0.9bar


PSHRB0011

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: 0...1bar
Max. pressure: 4bar


PSHRB0041

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: 0...4bar
Max. pressure: 8bar


PSHRB0101

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: 0...10bar
Max. pressure: 20bar


PSHRB0161

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: 0...16bar
Max. pressure: 32bar


PSHRB0251

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: 0...25bar
Max. pressure: 50bar


PSHRB0401

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: 0...40bar
Max. pressure: 80bar


PSHRV1011

Honeywell Electronic Pressure switch for gas and liquid (Smart DCM)

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.
Features:
Open-collector
Configurable as min./max/window monitor
Adjustable drop-in/drop-out delay
Hysteresis defined by set-point and reset-point
Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Protection class: IP65
Ambient temperature: -20...70C

Pressure Switch HMI
Pressure range: -1...1bar
Max. pressure: 4bar


PST001RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...1bar
Max. pressure: 6bar
Kind of pressure: overpressure, relative


PST001RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...1bar
Max. pressure: 6bar
Kind of pressure: overpressure, relative


PST002AG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...2bar
Max. pressure: 6bar
Kind of pressure: absolute


PST002AG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...2bar
Max. pressure: 6bar
Kind of pressure: absolute


PST002RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...1.6bar
Max. pressure: 6bar
Kind of pressure: overpressure, relative


PST002RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...1.6bar
Max. pressure: 6bar
Kind of pressure: overpressure, relative


PST004RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...4bar
Max. pressure: 12bar
Kind of pressure: overpressure, relative


PST004RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...4bar
Max. pressure: 12bar
Kind of pressure: overpressure, relative


PST010AG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...10bar
Max. pressure: 30bar
Kind of pressure: absolute


PST010AG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...10bar
Max. pressure: 30bar
Kind of pressure: absolute


PST010RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...10bar
Max. pressure: 30bar
Kind of pressure: overpressure, relative


PST010RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...10bar
Max. pressure: 30bar
Kind of pressure: overpressure, relative


PST025RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...25bar
Max. pressure: 75bar
Kind of pressure: overpressure, relative


PST025RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...25bar
Max. pressure: 75bar
Kind of pressure: overpressure, relative


PST060RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...60bar
Max. pressure: 180bar
Kind of pressure: overpressure, relative


PST100RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...100bar
Max. pressure: 300bar
Kind of pressure: overpressure, relative


PST250RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...250bar
Max. pressure: 500bar
Kind of pressure: overpressure, relative


PST600RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...600bar
Max. pressure: 1000bar
Kind of pressure: overpressure, relative


PSTM250RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...0.25bar
Max. pressure: 1bar
Kind of pressure: overpressure, relative


PSTM250RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...0.25bar
Max. pressure: 1bar
Kind of pressure: overpressure, relative


PSTM400RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...0.4bar
Max. pressure: 2bar
Kind of pressure: overpressure, relative


PSTM400RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...0.4bar
Max. pressure: 2bar
Kind of pressure: overpressure, relative


PSTM600RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: 0...0.6bar
Max. pressure: 2bar
Kind of pressure: overpressure, relative


PSTM600RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: 0...0.6bar
Max. pressure: 2bar
Kind of pressure: overpressure, relative


PSTV01RG12S-R

Honeywell Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output-signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !
Output signal: 0..10Vdc / 4..20 mA + switch + relay
Sensing element material: 1.4571 + 1.4542

Switch + Transmitter + Relay output
Pressure range: -1...1bar
Max. pressure: 6bar
Kind of pressure: vacuum, relative


PSTV01RG34F-R

Honeywell Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
all models: switch output open collector; 14..36 Vdc, 250 mA and relay output with gold plated SPDT contact
Protection class: IP65
Housing material: Polybutylene terephtalate (PBT)
Sensing element material: 1.4571 + 1.4435
Media temp.: -20...100C
Media temp. limit: Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature: -20...60C
Switch function/capacity: All models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.
Applicable parameter settings:
switching Set / Reset points
filters
analog output range
electrical drag indicator
Applicable configurations:
Max-Min, Window monitor
Analog output signal
Pressure unit
Simulation mode
Plugs have to be ordered separately !

Switch + Transmitter + Relay output
Pressure range: -1...1bar
Max. pressure: 6bar
Kind of pressure: vacuum, relative


PTE006BGG23B

Honeywell Pressure Transmitter for gas and liquid (PTE)

PTE Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor featuring thick-film technology offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature-compensated, calibrated, and amplified, the PTE is available in 0...40 bar pressure ranges.
The principal application are in Compressors, Refrigeration and HVAC, General industrial, General hydraulics, Multiple transportation applications including braking and alternate fuels, Medical.
Media temp.: -40...125C
Protection class: IP65
Pressure connection: G1/2

Electrical connection DIN 175301-C
Pressure range: 0...6bar
Max. pressure: 18bar


PTE010BGG23B

Honeywell Pressure Transmitter for gas and liquid (PTE)

PTE Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor featuring thick-film technology offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature-compensated, calibrated, and amplified, the PTE is available in 0...40 bar pressure ranges.
The principal application are in Compressors, Refrigeration and HVAC, General industrial, General hydraulics, Multiple transportation applications including braking and alternate fuels, Medical.
Media temp.: -40...125C
Protection class: IP65
Pressure connection: G1/2

Electrical connection DIN 175301-C
Pressure range: 0...10bar
Max. pressure: 30bar


PTE016BGG23B

Honeywell Pressure Transmitter for gas and liquid (PTE)

PTE Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor featuring thick-film technology offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature-compensated, calibrated, and amplified, the PTE is available in 0...40 bar pressure ranges.
The principal application are in Compressors, Refrigeration and HVAC, General industrial, General hydraulics, Multiple transportation applications including braking and alternate fuels, Medical.
Media temp.: -40...125C
Protection class: IP65
Pressure connection: G1/2

Electrical connection DIN 175301-C
Pressure range: 0...16bar
Max. pressure: 48bar


PTE025BGG23B

Honeywell Pressure Transmitter for gas and liquid (PTE)

PTE Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor featuring thick-film technology offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature-compensated, calibrated, and amplified, the PTE is available in 0...40 bar pressure ranges.
The principal application are in Compressors, Refrigeration and HVAC, General industrial, General hydraulics, Multiple transportation applications including braking and alternate fuels, Medical.
Media temp.: -40...125C
Protection class: IP65
Pressure connection: G1/2

Electrical connection DIN 175301-C
Pressure range: 0...25bar
Max. pressure: 75bar


PTE040BGG23B

Honeywell Pressure Transmitter for gas and liquid (PTE)

PTE Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor featuring thick-film technology offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature-compensated, calibrated, and amplified, the PTE is available in 0...40 bar pressure ranges.
The principal application are in Compressors, Refrigeration and HVAC, General industrial, General hydraulics, Multiple transportation applications including braking and alternate fuels, Medical.
Media temp.: -40...125C
Protection class: IP65
Pressure connection: G1/2

Electrical connection DIN 175301-C
Pressure range: 0...40bar
Max. pressure: 80bar


PTHDB0012A2

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (2-wire)
Pressure range: 0...1bar
Max. pressure: 3bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0012V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (3-wire)
Pressure range: 0...1bar
Max. pressure: 3bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0032A2

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (2-wire)
Pressure range: 0...3bar
Max. pressure: 9bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0032V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (3-wire)
Pressure range: 0...3bar
Max. pressure: 9bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0062A2

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (2-wire)
Pressure range: 0...6bar
Max. pressure: 21bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0062V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (3-wire)
Pressure range: 0...6bar
Max. pressure: 21bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0202A2

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (2-wire)
Pressure range: 0...20bar
Max. pressure: 60bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDB0202V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (3-wire)
Pressure range: 0...20bar
Max. pressure: 60bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDM1002A2

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (2-wire)
Pressure range: 0...0.1bar
Max. pressure: 0.9bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDM1002V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (3-wire)
Pressure range: 0...0.1bar
Max. pressure: 0.9bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDM3002A2

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (2-wire)
Pressure range: 0...0.3bar
Max. pressure: 0.9bar
Protection class: IP65
Ambient temperature: -20...70C


PTHDM3002V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp.: -20...80C

Pressure Transmitter with HMI (3-wire)
Pressure range: 0...0.3bar
Max. pressure: 0.9bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0011A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: 0...1bar
Max. pressure: 4bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0011V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: 0...1bar
Max. pressure: 4bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0041A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: 0...4bar
Max. pressure: 8bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0041V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: 0...4bar
Max. pressure: 8bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0101A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: 0...10bar
Max. pressure: 20bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0101V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: 0...10bar
Max. pressure: 20bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0161A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: 0...16bar
Max. pressure: 32bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0161V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: 0...16bar
Max. pressure: 32bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0251A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: 0...25bar
Max. pressure: 50bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0251V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: 0...25bar
Max. pressure: 50bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0401A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: 0...40bar
Max. pressure: 80bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRB0401V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: 0...40bar
Max. pressure: 80bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRV1011A2

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (2-wire, 4-20 mA)
Pressure range: -1...1bar
Max. pressure: 4bar
Protection class: IP65
Ambient temperature: -20...70C


PTHRV1011V3

Honeywell Electronic Pressure transmitter for gas and liquid (Smart SN)

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software
Media temp.: -20...80C
Sensing element material: 1.4571
Certificates: All 2-wire versions are SIL2 approved according IEC 61508

Pressure Transmitter with HMI (3-wire, 0-10 V)
Pressure range: -1...1bar
Max. pressure: 4bar
Protection class: IP65
Ambient temperature: -20...70C


PTSDB0012V3

Honeywell Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.
Features:
Configurable as 0/2...10V or 0/4...20 mA (3-wire)
Adjustable attenuation filter
LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o
Self-monitoring electronics
Power supply 24 VAC/DC (3-wire models)
Power supply 18-35 V DC (2-wire models)
Media temp